Configuration: BNI IOL-104-S02-Z012 extended with 22/24 Valve Terminal
Extension Port
Configuration
Any of the three different Valve Terminal variants can be connected to the device
via the Extension Port:
Configuration
ISDU Index 55
hex
value
Device alone (Extension Port not active)
0
Device with
same device
1
Device with
BNI IOL-751-V08-K007
2
Device with
BNI IOL-751-V10-K007
3
Device with
BNI IOL-751-V13-K007
4
However BNI IOL-104-S02-Z012 is a digital input module, which does not require UA Voltage,
this configuration with Valve Terminal requires the UA Voltage to drive the Valve Terminal’s
output.
Note
UA Voltage required.
IO-Link Data
BNI IOL-104-S02-Z012 with 22/24 Valve Terminal
Transfer rate
COM2 (38.4 kBaud)
Minimum cycle time
5.6 ms
Process data length
4 bytes input, 4 bytes output