background image

www.balluff.com

5

english

1.1 

Validity

This guide provides all the necessary information for the 

safe use of the following Balluff network interfaces:
– 

BNI IOL-104-011-K006 

Order code: BNI00J0

Read this guide and the other applicable documents 

completely before installing and operating the product.

Original User’s Guide

This guide was created in German. Other language 

versions are translations of this guide.
© Copyright 2022, Balluff GmbH

All contents are protected by copyright. All rights reserved, 

including the right to reproduce, publish, edit and translate 

this document.

1.2 

Other applicable documents

Additional information about this product can be found at 

www.balluff.com

 on the product page, e.g. in the fol-

lowing documents:
–  Data sheet

–  Declaration of Conformity

–  Disposal

1.3 

Symbols and conventions

Individual

 actions

 are indicated by a preceding triangle.

 

Instruction 1

Action sequences

 are numbered:

1. 

Instruction 1

2. 

Instruction 2

Numbers

 unless otherwise indicated are decimals 

(e.g. 23). Hexadecimal numbers are represented with a 

preceding 0x (e.g. 0x12AB).

Note, tip

This symbol indicates general notes.

1.4 

Explanation of the warnings

Always observe the warnings in this guide and the 

measures described to avoid hazards.
The warnings used here contain various signal words and 

are structured as follows:

SIGNAL WORD

Type and source of the hazard

Consequences if not complied with

 

Measures to avoid hazards

The individual signal words mean:

NOTICE

Identifies a danger that could 

damage or destroy the 

product

.

  DANGER

The general warning symbol in conjunction with the 

signal word DANGER identifies a hazard which, if not 

avoided, will certainly result in 

death or serious injury

.

1.5 

Technical terms and abbreviations used

C/Q

Switching and communication line

DPP

Direct Parameter Page

E-Port

Digital input port

EMC

Electromagnetic compatibility

FE

Functional earth

GND

Electrical ground, 0 V

IODD

IO-Device-Description

IOL

IO-Link

ISDU

IO-Link-Parameter (Index Service Data Unit)

LSB

Least Significant Bit

MSB

Most Significant Bit

U

S

Sensor supply

User instructions for this guide

BNI IOL-104-011-K006

Network interface – Digital hub

Содержание BNI IOL-104-011-K006

Страница 1: ...BNI IOL 104 011 K006 deutsch Betriebsanleitung english User s Guide...

Страница 2: ...www balluff com...

Страница 3: ...BNI IOL 104 011 K006 Betriebsanleitung deutsch...

Страница 4: ...www balluff com...

Страница 5: ...geelemente 9 4 4 Bedruckung 9 5 Einbau und Anschluss 10 5 1 Einbau 10 5 2 Elektrischer Anschluss 10 5 2 1 Spannungsversorgung 10 5 2 2 IO Link Schnittstelle 10 5 2 3 Digitaler Eingangs Port 10 5 3 Sch...

Страница 6: ...ntsorgung 17 10 Technische Daten 18 10 1 Umgebungsbedingungen 18 10 2 Elektrische Merkmale 18 10 3 Elektrischer Anschluss 18 10 4 Schnittstelle 18 10 5 Material 18 10 6 Mechanische Merkmale 18 10 7 Zu...

Страница 7: ...chnung sind Dezimalzahlen z B 23 Hexadezimale Zahlen werden mit vorangestell tem 0x dargestellt z B 0x12AB Hinweis Tipp Dieses Symbol kennzeichnet allgemeine Hinweise 1 4 Bedeutung der Warnhinweise Be...

Страница 8: ...h 2 3 Allgemeine Sicherheitshinweise T tigkeiten wie Einbau Anschluss und Inbetriebnahme d rfen nur durch geschulte Fachkr fte erfolgen Eine geschulte Fachkraft ist wer aufgrund seiner fachli chen Aus...

Страница 9: ...lb getrennt zu bestellen Empfohlenes Zubeh r finden Sie unter www balluff com auf der Produktseite 3 2 Transport Produkt in Originalverpackung bis zum Verwendungs ort transportieren 3 3 Lagerbedingung...

Страница 10: ...Eingangs Port 1 4 Standard Eingangs Port 3 5 Status LED 1 Eingang Pin 2 6 Standard Eingangs Port 5 7 Status LED 0 Eingang Pin 4 8 Status LED Versorgung Sensoren US 9 Standard Eingangs Port 7 10 Stand...

Страница 11: ...des Ger ts ist zu niedrig 18 V Aus Modul ist ohne Spannung IOL Gr n nega tiv gepulst IO Link Kommunikation ist aktiv Das Ger t ist bereit Gr n statisch Keine Kommunikation Aus Modul ist ohne Spannung...

Страница 12: ...er falsche Polarit t der Anschl sse kann zu Funktionsverlust oder einer Besch digung des Produkts f hren Ma nahmen treffen um einen fehlerhaften Anschluss oder eine Verpolung zu verhindern Herumhantie...

Страница 13: ...an den bergeordneten IO Link Master erfolgt mit einem Standard Sensorkabel Die Anbindung von digitalen Sensoren an den beschriebe nen Hub erfolgt mit standardisierten ungeschirmten Sensorkabeln Kabel...

Страница 14: ...dere nach dem Austausch des BNI oder der Reparatur durch den Hersteller die korrekten Werte pr fen 6 2 Betrieb Hinweise zum Betrieb Funktion des BNI und aller damit verbundenen Kompo nenten regelm ig...

Страница 15: ...ikationsdaten DPP Name Index Zugriff L nge Datentyp Data Storage Default Vendor Name 0x0007 7 R 2 Byte STRING n a 0x0378 Vendor Text 0x0008 8 R STRING n a Product Name 0x0009 9 R 3 Byte STRING n a 0x0...

Страница 16: ...nvertierung Port 5 Pin 2 Invertierung Port 4 Pin 2 Invertierung Port 3 Pin 2 Invertierung Port 2 Pin 2 Invertierung Port 1 Pin 2 Invertierung Port 0 Pin 2 Invertierung Port x 0 normal 1 invertiert Spa...

Страница 17: ...8023 Access denied 0x8033 Parameter length overrun 0x8034 Parameter length underrun 0x8035 Function not available Tab 7 4 Fehlercodes 7 4 Events Event Code Beschreibung 0x5111 Low sensor voltage US 0x...

Страница 18: ...bertragen wodurch minimale Ausfallzeiten garantiert werden Um die Datenhaltung zu verwenden muss die Validierung eingeschaltet werden Informationen zu der Konfigurierung der Datenhaltung und Validier...

Страница 19: ...ie Kontakt mit unserem Service Center auf 9 2 Demontage Ger t nur in spannungsfreiem Zustand demontieren 9 3 Entsorgung Befolgen Sie die nationalen Vorschriften zur Entsor gung Weitere Informationen f...

Страница 20: ...Buchse 10 4 Schnittstelle IO Link Version 1 1 Daten bertragungsrate COM2 38 4 kBit s Minimale Zykluszeit 3 5 ms Prozessdatenl nge 2 Byte Eingang 10 5 Material Geh usematerial Kunststoff transparent 1...

Страница 21: ...BNI IOL 104 011 K006 User s Guide english...

Страница 22: ...www balluff com...

Страница 23: ...4 4 Labeling 9 5 Installation and connection 10 5 1 Installation 10 5 2 Electrical connection 10 5 2 1 Power supply 10 5 2 2 IO Link interface 10 5 2 3 Digital input port 10 5 3 Shielding and cable r...

Страница 24: ...mbly 17 9 3 Disposal 17 10 Technical data 18 10 1 Ambient conditions 18 10 2 Electrical data 18 10 3 Electrical connection 18 10 4 Interface 18 10 5 Materials 18 10 6 Mechanical features 18 10 7 Appro...

Страница 25: ...icated are decimals e g 23 Hexadecimal numbers are represented with a preceding 0x e g 0x12AB Note tip This symbol indicates general notes 1 4 Explanation of the warnings Always observe the warnings i...

Страница 26: ...s 2 3 General safety notes Activities such as installation connection and startup may only be carried out by qualified personnel Qualified personnel are persons whose technical trai ning knowledge and...

Страница 27: ...y and must be ordered separately Recommended accessories can be found at www balluff com on the product page 3 2 Transport Transport product to location of use in original packaging 3 3 Storage condit...

Страница 28: ...Link interface 3 Standard input port 1 4 Standard input port 3 5 Status LED 1 Input Pin 2 6 Standard input port 5 7 Status LED 0 Input Pin 4 8 Status LED Sensor supply US 9 Standard input port 7 10 S...

Страница 29: ...ating voltage of the device is too low 18 V Off Module without supply voltage IOL Green negative pulsing IO Link communication is active The device is ready Green static No communication Off Module wi...

Страница 30: ...onnection or polarity of the connections can cause a loss of function or damage to the product Take measures to prevent incorrect connection or reverse polarity Prevent tampering at the connections Ne...

Страница 31: ...ing The connection to the higher level IO Link master is made with a standard sensor cable Digital sensors are connected to the described hub using standardized unshielded sensor cables Cable length T...

Страница 32: ...for the correct values especially after replacing the BNI or after repair by the manufac turer 6 2 Operation Operating notes Regularly check function of the BNI and all associated components Depending...

Страница 33: ...PP Name Index Access Length Data Type Data Storage Default Vendor Name 0x0007 7 R 2 bytes STRING n a 0x0378 Vendor text 0x0008 8 R STRING n a Product Name 0x0009 9 R 3 bytes STRING n a 0x050112 Produc...

Страница 34: ...n 2 Inversion Port 5 Pin 2 Inversion Port 4 Pin 2 Inversion Port 3 Pin 2 Inversion Port 2 Pin 2 Inversion Port 1 Pin 2 Inversion Port 0 Pin 2 Inversion Port x 0 normal 1 inverted Voltage monitoring By...

Страница 35: ...e 0x8023 Access denied 0x8033 Parameter length overrun 0x8034 Parameter length underrun 0x8035 Function not available Tab 7 4 Error codes 7 4 Events Event Code Description 0x5111 Low sensor voltage US...

Страница 36: ...sferred to the new device thus guaranteeing minimum downtimes In order to use the data storage the validation must be switched on Information about the configuration of the data storage and validation...

Страница 37: ...ive contact our Service Center 9 2 Disassembly Only disassemble the device when it is de energized 9 3 Disposal Observe the national regulations for disposal Additional information can be found at www...

Страница 38: ...8 M12 A coded 4 pin socket 10 4 Interface IO Link version 1 1 Data transmission rate COM2 38 4 kBit s Minimum cycle time 3 5 ms Process data length 2 bytes input 10 5 Materials Housing material Plasti...

Страница 39: ......

Страница 40: ...hengshan Rd 8F Building A Yunding International Commercial Plaza 200125 Pudong Shanghai Phone 86 400 820 0016 Fax 86 400 920 2622 service cn balluff com cn DACH Service Center Germany Balluff GmbH Sch...