Installation and connection

Sensor head and magnetic tape

During assembly, make sure that the sensor head is 

correctly aligned to the magnetic tape.

The magnetic tape is not included in the scope

of delivery and must be ordered separately. 

When selecting the magnetic tape, make sure 

that the magnetic tape and sensor head are 

compatible. This particularly applies to the 

following:

–  Pole width

–  Reference points

When positioning the sensor head and magnetic 

tape, make sure that they are aligned correctly 

to each other. Orientation arrows are printed on 

the part label of the sensor head and magnetic 

tape for this purpose. These must be pointing in 

the same direction.

Alternatively, the orientation of the tape can be 

determined using a pole pitch display card 

(included with the BAM TO-ML-014-02 

assembly accessories).

To ensure correct operation or to obtain the 

required measurement accuracy, adhere to the 

assembly tolerances for the specific application. 

The values in the table below apply for the 

recommended alignment. The mechanical 

tolerances and measurement accuracy can be 

obtained from the detailed user's guide.

The code on the part label of the sensor head 

and on the magnetic tape must be identical.

BML SF2-_ _ _ 1-… (longitudinal variant)

jjwwDE

Code

Code

Sensor head part label

Code

Orientation arrow

BML SF2-_ _ _ 2-… (transverse variant)

jjwwDE

Code

Code

Code

Sensor head part label

Orientation arrow

Mechanical tolerances

No reference point function

BML SF2-_ _

0

_-…

or with pole-periodic reference point 

function

BML SF2-_ _

2

_-…

With integrated reference sensor

BML SF2-_ _

1

_-…

Longitudinal  

variant

SF2-_ _ _

1

-…

Transverse  

variant

SF2-_ _ _

2

-…

Longitudinal 

variant 

SF2-_ _ _

1

-…

Transverse  

variant

SF2-_ _ _

2

-…

Z

  

(air gap sensor/magnetic tape)

0.2 mm

Z

  

(air gap between sensor/

magnetic tape with cover strip)

Y

 (transverse offset)

3 mm

2.5 mm

0.5 mm

1)

 / 0.2 mm

2)

0 mm

1)

 / –0.3 mm

2)

Pitch

Yaw
Roll

1)  Nominal value for maximum Y tolerance
2)  Nominal value for minimal influence on measurement accuracy

Содержание BML SF2-I2 A Series

Страница 1: ...L SF2 I2_ _ A QZ_ _ Z_ _5 KA KD KF_ _ BML SF2 I2_ _ A QZ_ _ Z_ _5 KA_ _ S284 deutsch Kurzanleitung english Condensed guide fran ais Notice r sum e italiano Istruzioni brevi espa ol Instrucciones breve...

Страница 2: ...gen des Weg messsystems ist dieses au er Betrieb zu nehmen und gegen unbefugte Benutzung zu sichern Abmessungen und Funktion Das BML ist ein magnetkodiertes ber hrungsloses inkrementelles Wegmesssyste...

Страница 3: ...ion zu gew hrleisten bzw um die geforderte Messgenauigkeit zu erlangen m ssen anwendungsspezifische Montagetole ranzen eingehalten werden F r eine empfohlene Ausrichtung gelten die Werte in folgender...

Страница 4: ...ibereich magnetisierbarer Materialien BML SF2 _ _ _2 X 5 5 Z 13 X 3 Y 1 Yaw Pitch Yaw Pitch Roll Roll Inkrementalsensor Referenzsensor Freibereich magnetisierbarer Materialien 1 1 Verfahrrichtung vorw...

Страница 5: ...sf rmiges Analogsignal A Digitales Rechtecksignal 3 GN GN GN A Sin Sinusf rmiges Analogsignal B Digitales Rechtecksignal 4 YE YE YE A Sin Sinusf rmiges Analogsignal B Digitales Rechtecksignal 5 GY GY...

Страница 6: ...en Magnetfelder Das Wegmesssystem ist ein magnetkodiertes System Auf ausreichenden Abstand des Wegmesssystems zu starken externen Magnetfeldern achten Nr 938835 DE C18 nderungen vorbehalten Schirmung...

Страница 7: ...der system take it out of service and secure against unauthorized use Dimensions and function The BML is a non contact incremental magnetic linear encoder consisting of a sensor head and magnetic tape...

Страница 8: ...n the required measurement accuracy adhere to the assembly tolerances for the specific application The values in the table below apply for the recommended alignment The mechanical tolerances and measu...

Страница 9: ...nsor Free area of magnetizable material BML SF2 _ _ _2 X 5 5 Z 13 X 3 Y 1 Yaw Pitch Yaw Pitch Roll Roll Incremental sensor Reference sensor Free area of magnetizable material 1 1 Forward direction of...

Страница 10: ...signal A Digital square wave signal 3 GN GN GN A Sin Sinusoidal analog signal B Digital square wave signal 4 YE YE YE A Sin Sinusoidal analog signal B Digital square wave signal 5 GY GY GY Must remai...

Страница 11: ...id going near high voltage cables due to interferences Magnetic fields The position measuring system is a magnetically coded system It is important to maintain adequate distance between the position m...

Страница 12: ...syst me de mesure de d placement celui ci doit tre mis hors service et prot g contre toute utilisation non autoris e Dimensions et fonction Le BML est un syst me de mesure de d placement incr mental c...

Страница 13: ...enir la pr cision de mesure exig e les tol rances de montage sp cifiques l application doivent tre respect es Les valeurs contenues dans la table suivante sont valables pour une orientation recommand...

Страница 14: ...ne libre de mat riaux magn tisables BML SF2 _ _ _2 X 5 5 Z 13 X 3 Y 1 Yaw Pitch Yaw Pitch Roll Roll Capteur incr mental Capteur de r f rence Zone libre de mat riaux magn tisables 1 1 Sens de d placeme...

Страница 15: ...rectangulaire num rique 4 YE YE YE A Sin Signal analogique de type sinuso dal B Signal rectangulaire num rique 5 GY GY GY Doit rester libre Z Doit rester libre Z Signal de r f rence 6 PK PK PK Z Z 7 B...

Страница 16: ...c bles haute tension en raison de couplages parasites Champs magn tiques Le syst me de mesure de d placement est un syst me codage magn tique Veiller ce que le syst me de mesure de d placement se trou...

Страница 17: ...o contro l uso non autorizzato Dimensioni e funzionamento Il BML un sistema di misura della corsa incrementale senza contatto con codifica magnetica costituito da una testa sensore e un corpo di misur...

Страница 18: ...la precisione di misura richiesta necessario rispettare le tolleranze di montaggio specifiche dell applicazione Per un allineamento consigliato si applicano i valori riportati nella seguente tabella L...

Страница 19: ...to Area libera da materiali magnetizzabili BML SF2 _ _ _2 X 5 5 Z 13 X 3 Y 1 Yaw Pitch Yaw Pitch Roll Roll Sensore incrementale Sensore di riferimento Area libera da materiali magnetizzabili 1 1 Direz...

Страница 20: ...ico sinusoidale A Digitale segnale rettangolare 3 GN GN GN A Sin Segnale analogico sinusoidale B Digitale segnale rettangolare 4 YE YE YE A Sin Segnale analogico sinusoidale B Digitale segnale rettang...

Страница 21: ...vitare la vicinanza di linee ad alta tensione a causa dell interferenza di disturbi Campi magnetici L encoder un sistema a codifica magnetica Mantenere una distanza sufficiente dell encoder dai campi...

Страница 22: ...debe impedir cualquier uso no autorizado Dimensiones y funcionamiento El BML es un sistema de medici n de desplazamiento incremental sin contacto de codificaci n magn tica formado por una cabeza de se...

Страница 23: ...nseguir la exactitud de la medici n exigida es necesario que se cumplan las tolerancias de montaje espec ficas de cada aplicaci n Los valores de la siguiente tabla son aplicables para una alineaci n r...

Страница 24: ...cia Zona libre de materiales magnetizables BML SF2 _ _ _2 X 5 5 Z 13 X 3 Y 1 Yaw Pitch Yaw Pitch Roll Roll Sensor incremental Sensor de referencia Zona libre de materiales magnetizables 1 1 Sentido de...

Страница 25: ...a senoidal A se al digital de onda rectangular 3 GN GN GN A Sin se al anal gica senoidal B se al digital de onda rectangular 4 YE YE YE A Sin se al anal gica senoidal B se al digital de onda rectangul...

Страница 26: ...en las proximidades para evitar el acoplamiento de interferencias Campos magn ticos El sistema de medici n de desplazamiento es un sistema de codificaci n magn tica Se debe asegurar que exista suficie...

Страница 27: ...uff com service balluff de CE EMV E227256 BML SF2 I2_ _ A QZ_ _ Z_ _5 BML 1 mT 30 mT 30 mT 10 05 0 1 13 1 0 1 2 M4 35 0 05 12 0 05 5 0 05 12 0 05 8 25 D 1 49 14 5 M12 LED LED KA KD KF_ _ KA_ _ S284 1...

Страница 28: ...TO ML 014 02 BML SF2 _ _0_ BML SF2 _ _2_ BML SF2 _ _1_ SF2 _ _ _1 SF2 _ _ _2 SF2 _ _ _1 SF2 _ _ _2 Z 0 2 mm Z Y 3 mm 2 5 mm 0 5 mm1 0 2 mm2 0 mm1 0 3 mm2 0 1 Y 2 BML SF2 _ _ _ 1 jjwwDE Code Code BML...

Страница 29: ...BML SF2 I2_ _ A QZ_ _ Z_ _5 BML SF2 _ _ _1 Z X X 10 5 5 Y 1 BML SF2 _ _ _2 X 5 5 Z 13 X 3 Y 1 1 1 A B 30 mm 3 www balluff com...

Страница 30: ...Q 1_ Q 2_ Q 1 WH WH WH B Cos A 2 BN BN BN B Cos A 3 GN GN GN A Sin B 4 YE YE YE A Sin B 5 GY GY GY Z Z 6 PK PK PK Z Z 7 BU BU BU GND3 0V 8 RD RD RD 5 V DC 9 BK BK GND Sense GND Sense 10 VT VT V DC Se...

Страница 31: ...M4 M4 M3 www balluff com EMC 938835 ZH C18 KA_ _ 7 5 D KA_ _ 15 D KF_ _ 5 D KF_ _ 15 D KD_ _ 3 D KD_ _ 7 D 20 m BML 0 2 Ohm m 0 4 Ohm m 1 2 3 BML SF2 I2_ _ A QZ_ _ Z_ _5 5 www balluff com...

Страница 32: ...9 73765 Neuhausen a d F Phone 49 7158 173 370 Fax 49 7158 173 691 service balluff de US Service Center USA Balluff Inc 8125 Holton Drive Florence KY 41042 Phone 859 727 2200 Toll free 1 800 543 8390...

Отзывы: