www.balluff.com
31
english
Statistics Data Output: Status
Bit
position
Meaning
Description
0
Configured
1 – all inputs are configured
1
Started Min/
Max/Avg
1 – Min/Max/Avg running
2
Started Moving
Average
1 –
Moving Average
running
3
Buffer Overflow
Event
1 – buffer overflow
4
Timeout Event
1 – the set time for the
minimum value/maximum
value/average calculation
has elapsed
5
Reserved
–
6
Reserved
–
7
Reserved
–
Tab. 5-7: Statistics Data Output – Status
5.1.5 System Commands
Command Value Device Action
0xA7 (167)
Statistics Reset
– Resets all output
parameters to 0 and all user
settings to the default values.
0xA8 (168)
Statistics Start Min/Max/Avg
–
Starts the statistics of the minimum
value/maximum value/average
calculation.
0xA9 (169)
Statistics Stop
– Stops statistics
operation completely.
0xAC (172)
Statistics Start Moving Average
– Starts the statistics of the moving
average calculation.
Tab. 5-8: Basic statistics – System Commands
For an overview of all System Commands, see section 3.5
on page 17.
5.1.6 Events
Event Code
Event Type
Description
Device Status
0x8D07 (36103)
Warning
The calculation of the basic statistics was stopped
automatically to avoid a buffer overflow.
0 – Device is
operating properly.
0x8D0E (36110)
Notification
The time has elapsed. This event reports the timeout of
the minimum value/maximum value/average calculation.
It does not report a timeout for the calculation of the
moving average because the timer repeats and it does
not indicate the end of the calculation.
0 – Device is
operating properly.
Tab. 5-9: Basic statistics – Events