12
english
Name
Index
Subindex Access
Length
Data Type
Data
Storage
Default
RFID parameters
RFID parameter
0x0040
(64)
0
R/W
6 bytes
Record
Yes
–
CRC yes/no
1
R/W
1 byte
UINT8
–
0
Dynamic operation
2
R/W
1 byte
UINT8
–
0
Action at
Tag Present
3
R/W
1 byte
UINT8
–
1
Start address lowbyte
for autoread
4
R/W
1 byte
UINT8
–
0
Start address highbyte
for autoread
5
R/W
1 byte
UINT8
–
0
Data carrier type used
6
R/W
1 byte
UINT8
–
0
RFID Parameter
extended
0x0080
(128)
0
R/W
7 bytes
Record
Yes
–
CRC yes/no
1
R/W
1 byte
UINT8
–
0
Dynamic operation
2
R/W
1 byte
UINT8
–
0
Action at
Tag Present
3
R/W
1 byte
UINT8
–
1
Start address lowbyte
for autoread
4
R/W
1 byte
UINT8
–
0
Start address highbyte
for autoread
5
R/W
1 byte
UINT8
–
0
Data carrier type used
6
R/W
1 byte
UINT8
–
0
Readback
7
R/W
1 byte
UINT8
–
0
RFID information
RFID information
0x007F
(127)
0
R
1 byte
Record
n.a.
–
RSSI
1
R
1 byte
UINT8
n.a.
–
Signal quality
Low Signal Quality
Threshold
0x00CE
(206)
0
R/W
1 byte
UINT8
Yes
0
Signal Quality
0x00CF
(207)
0
R
2 bytes
–
n/a
–
Current Signal Quality
1
R
1 byte
UINT8
n/a
–
Signal Quality Bad
2
R
1 Bit
BOOL
n/a
–
3
Overview of IO-Link Data and Functions (continued)