www.balluff.com
13
english
Name
Index
Subindex Access
Length
Data Type
Data
Storage
Default
Basic Statistics
Statistics Data
Configuration
0x0426
(1062)
0
R/W
8 bytes
–
Yes
–
Input Signal
1
R/W
2 bytes
UINT16(ENUM)
No
0
Time Period Unit
2
R/W
1 byte
UINT8(ENUM)
No
Seconds
Time Period Value
3
R/W
2 bytes
UINT16
No
1
Moving Average
Window Unit
4
R/W
1 byte
UINT8(ENUM)
No
Measurement values
Moving Average
Window Value
5
R/W
2 bytes
UINT16
No
100
Statistics Data Output
0x0427
(1063)
0
R
21 bytes
–
n/a
–
Minimum
1
R
4 bytes
FLOAT32
n/a
–
Maximum
2
R
4 bytes
FLOAT32
n/a
–
Average
3
R
4 bytes
FLOAT32
n/a
–
Moving Average
4
R
4 bytes
FLOAT32
n/a
–
Number Of Samples
5
R
4 bytes
UINT32
n/a
–
Status
6
R
1 byte
UINT8
n/a
–
Operating Hours Counters
Operating Hours
Counter
0x0057
(87)
0
R
12 bytes
–
n/a
–
Current Operating
Hours
1
R
4 bytes
UINT32
n/a
–
Total Operating Hours
2
R
4 bytes
UINT32
n/a
–
Custom Operating
Hours
3
R
4 bytes
UINT32
n/a
–
Operating Hours
Saving Mode
0x0074
(116)
0
R/W
1 byte
UINT8(ENUM)
Yes
0
Boot Cycle Counter
Boot Cycle Counter
0x0058
(88)
0
R
8 bytes
–
n/a
–
Boot Cycle Counter
1
R
4 bytes
UINT32
n/a
–
Custom Boot Cycle
Counter
2
R
4 bytes
UINT32
n/a
–
3
Overview of IO-Link Data and Functions (continued)
BIS M-4 _ _ -082-401-07-…
Industrial RFID-System BIS M
Содержание BIS M-408-082-401-07-S4
Страница 2: ...www balluff com...
Страница 4: ...www balluff com...
Страница 66: ...www balluff com...
Страница 127: ......