The 

operator

 is responsible for ensuring that local safety 

regulations are observed.

In particular, the operator must take steps to ensure that a 

defect in the BIP will not result in hazards to persons or 

equipment.
If defects and unresolvable faults occur in the BIP, it should 

be taken out of service and secured against unauthorized 

use.

Construction and function

Dimensions

 

 

16

40.5

33.7 

±

0.5

1.5

0 0.1

4

 

– 0.05

Ø

D

4

19.4

22

30

10.9

2

4.4

18

4

17.3

0

Function

The BIP detects the position of the target and outputs it as 

a voltage or current signal.

The CE Mark verifies that our products  

meet the requirements of the current  

EMC Directive.

File No.

E227256

1

english

Notes to the user

Validity

This guide describes the construction, function, and setup 

options for the BIP inductive positioning system. It applies 

to types BIP AD2-T017-04-BP _ _ and 

BIP CD2-T017-04-BP _ _.
The guide is intended for qualified technical personnel. 

Read this guide before installing and operating the BIP.

Always observe the warnings in these instructions and the 

measures described to avoid hazards.

Scope of delivery

–  BIP

–  User’s guide

More detailed information on the guidelines, 

approvals, and standards is included in the 

declaration of conformity.

Safety

Intended use

The BIP inductive positioning system, together with a 

machine controller (e.g. PLC), comprises a positioning 

system. It is intended to be installed into a machine or 

system and used in the industrial sector. Flawless function 

in accordance with the specifications in the technical data 

is ensured only when using original Balluff accessories. 

Use of any other components will void the warranty.

Non-approved use

The BIP may not be used in applications where personal 

safety depends on proper function of the devices (not 

designed in accordance with EU Machinery Directive).
Opening the BIP or non-approved use are not permitted 

and will result in the loss of warranty and liability claims 

against the manufacturer.

General safety notes

Installation

startup

, and 

maintenance

 may only be 

performed by trained specialists with basic electrical 

knowledge. 

Qualified personnel 

are those who can 

recognize possible hazards and institute the appropriate 

safety measures due to their professional training, 

knowledge, and experience as well as their understanding 

of the relevant regulations pertaining to the work to be 

done.
Repairs may only be performed by the manufacturer or an 

authorized representative.
Do not attempt to make changes to the device or to 

modify it in any way.

Safety (continued)

BIP A/CD2-T017-04-BP _ _

Inductive Positioning System

Содержание BIP AD2-T017-04-BP Series

Страница 1: ...deutsch Betriebsanleitung english User s guide fran ais Notice d utilisation italiano Manuale d uso espa ol Manual de instrucciones BIP AD2 T017 04 BP_ _ BIP CD2 T017 04 BP_ _...

Страница 2: ...Bestimmungsgem e Verwendung Das induktive Positionsmesssystem BIP bildet zusammen mit einer Maschinensteuerung z B SPS ein Wegmess system Es wird zu seiner Verwendung in eine Maschine oder Anlage eing...

Страница 3: ...tig geerdet mit dem Schutzleiter verbunden werden Kabelverlegung Kabel zwischen BIP Steuerung und Stromversorgung nicht in der N he von Starkstromleitungen verlegen induktive Einstreuungen m glich Bes...

Страница 4: ...h blinkt die gr ne LED langsam weiter Nachdem alle 5 Kurvenpunkte auf diese Weise gespeichert wurden wird die Kommunikation beendet und die gr ne LED an der Einstellbox leuchtet wieder dauerhaft Fehle...

Страница 5: ...Verpolungssicher ja Ausgang BIP AD2 T017 04 BP_ _ Ausgangsspannung bei Sl Ausgangsspannung bei Se Lastwiderstand RL 0 V 10 V 5 V 2000 BIP CD2 T017 04 BP_ _ Ausgangsstrom bei Sl Ausgangsstrom bei Se La...

Страница 6: ...d in the declaration of conformity Safety Intended use The BIP inductive positioning system together with a machine controller e g PLC comprises a positioning system It is intended to be installed int...

Страница 7: ...controller side connected with the protective earth conductor Cable routing Do not route the cable between the BIP controller and power supply near high voltage cables inductive stray noise is possib...

Страница 8: ...ng quickly Afterwards the green LED continues to flash slowly After all 5 curve points have been saved in this way communication is stopped and the green LED on the calibration box lights up permanent...

Страница 9: ...otection Yes Protected against miswiring Yes Polarity reversal protected Yes Output BIP AD2 T017 04 BP_ _ Output voltage at Sl Output voltage at Se Load resistance RL 0 V 10 V 5 V 2000 BIP CD2 T017 04...

Страница 10: ...nforme aux prescriptions Coupl une commande de machine p ex API le syst me de mesure de position inductif BIP constitue un syst me de mesure de d placement Il est mont dans une machine ou une installa...

Страница 11: ...es Ne pas poser le c ble reliant le BIP la commande et l alimentation proximit de c bles de puissance risques de perturbations inductives Les perturbations inductives cr es par des ondes harmoniques p...

Страница 12: ...D verte continue de clignoter lentement Apr s que tous les 5 points de courbe aient t enregistr s de cette mani re la communication est coup e et la LED verte du bo tier de r glage est de nouveau allu...

Страница 13: ...D2 T017 04 BP_ _ Tension de sortie Sl Tension de sortie Se R sistance de charge RL 0 V 10 V 5 V 2000 BIP CD2 T017 04 BP_ _ Courant de sortie Sl Courant de sortie Se R sistance de charge RL 4 mA 20 mA...

Страница 14: ...o BIP costituisce insieme a un comando macchina p es PLC un sistema di misura della corsa Per poter essere utilizzato il sistema deve essere montato su una macchina o su un impianto ed destinato all i...

Страница 15: ...terra sul lato unit di comando collegata con il conduttore di protezione Posa dei cavi Non posare i cavi fra BIP unit di controllo e alimentazione elettrica in prossimit di linee ad alta tensione sono...

Страница 16: ...lentamente Dopo aver salvato analogamente tutti i 5 punti di curva la comunicazione termina e il LED verde sulla scatola di regolazione torna ad accendersi in modo continuo Errore Se il BIP non compa...

Страница 17: ...Uscita BIP AD2 T017 04 BP_ _ Tensione in uscita a Sl Tensione in uscita a Se Resistenza di carico RL 0 V 10 V 5 V 2000 BIP CD2 T017 04 BP_ _ Corrente in uscita a Sl Corrente in uscita a Se Resistenza...

Страница 18: ...tivo BIP de medici n de posici n forma un sistema de medici n de desplazamiento junto con un control de m quina por ejemplo PLC Para utilizarlo se monta en una m quina o instalaci n y est previsto par...

Страница 19: ...unidad de control conexi n al conductor protector Tendido de cables No tender cables entre el BIP el control y la alimentaci n de corriente cerca de l neas de alta tensi n posibilidad de perturbacion...

Страница 20: ...nuaci n el LED verde sigue parpadeando lentamente Despu s de guardar los 5 puntos de curva de este modo la comunicaci n finaliza y el LED verde de la caja de ajuste se vuelve a iluminar constantemente...

Страница 21: ...AD2 T017 04 BP_ _ Tensi n de salida con Sl Tensi n de salida con Se Resistencia de carga RL 0 V 10 V 5 V 2000 BIP CD2 T017 04 BP_ _ Corriente de salida con Sl Corriente de salida con Se Resistencia de...

Страница 22: ...P BIP 16 40 5 33 7 0 5 1 5 0 0 1 4 0 05 D 4 19 4 22 30 10 9 2 4 4 18 4 17 3 0 BIP CE EMC E227256 1 BIP BIP AD2 T017 04 BP_ _ BIP CD2 T017 04 BP_ _ BIP BIP BIP PLC BALLUFF BIP BIP BIP A CD2 T017 04 BP_...

Страница 23: ...uff com 2 BIP 1 mm BIP 2 D 0 5 1 3 mm D 1 0 0 25 mm 17 5 4 D BAM TG XE 020 2 DIN EN ISO 4762 M4 x 10 BIP 0 5 Nm EMC BIP BN BK BU R L BAE PD XE 005 BAE00T3 BIP 17 mm BIP BIP LED BIP LED BIP A CD2 T017...

Страница 24: ...LED LED 3 4 LED LED LED 5 LED BIP LED LED LED BIP 2 8 s BIP 10V 20mA 0V 4mA 0mm 17mm Ua Ia S BIP AD2 0 10 9 5 2 1 0 17 P2 P3 P5 mm Ua S P1 P4 7 V BIP CD2 4 20 18 4 12 7 2 5 6 0 17 P2 P3 P5 mm Ia S P1...

Страница 25: ...30 g 11 ms EN 60068 2 6 55 Hz 1 mm 3 30 3 UB 2 15 30 V DC Ue 24 V DC Io Ue 20 mA Ue 10 UI 75 V DC BIP AD2 T017 04 BP_ _ Sl Se RL 0 V 10 V 5 V 2000 BIP CD2 T017 04 BP_ _ Sl Se RL 4 mA 20 mA 12 mA 500 9...

Страница 26: ...BIP 16 40 5 33 7 0 5 1 5 0 0 1 4 0 05 D 4 19 4 22 30 10 9 2 4 4 18 4 17 3 0 BIP CE EMC E227256 1 BIP BIP AD2 T017 04 BP_ _ BIP CD2 T017 04 BP_ _ BIP BIP BIP PLC Balluff BIP EU BIP BIP A CD2 T017 04 B...

Страница 27: ...ff com 2 BIP 1 mm BIP 2 D 0 5 1 3 mm D 1 0 0 25 mm 17 5 4 D BAM TG XE 020 BIP DIN EN ISO 4762 M4 x 10 2 0 5 Nm EMC BIP BN BK BU R L BAE PD XE 005 BAE00T3 BIP 17 mm 5 BIP BIP LED BIP LED BIP A CD2 T017...

Страница 28: ...LED 3 2 4 LED LED LED 5 LED BIP LED LED LED BIP 2 8 BIP 10V 20mA 0V 4mA 0mm 17mm Ua Ia S BIP AD2 0 10 9 5 2 1 0 17 P2 P3 P5 mm Ua S P1 P4 7 V BIP CD2 4 20 18 4 12 7 2 5 6 0 17 P2 P3 P5 mm Ia S P1 P4...

Страница 29: ...ms EN 60068 2 6 55 Hz 1 mm 3 30 min 3 UB 2 15 30 V DC Ue 24 V DC Io Ue 20 mA Ue 10 UI 75 V DC BIP AD2 T017 04 BP_ _ Sl Se RL 0 V 10 V 5 V 2000 BIP CD2 T017 04 BP_ _ Sl Se RL 4 mA 20 mA 12 mA 500 No 9...

Страница 30: ...e KY 41042 Phone 859 727 2200 Toll free 1 800 543 8390 Fax 859 727 4823 technicalsupport balluff com CN Service Center China Balluff Shanghai trading Co ltd Room 1006 Pujian Rd 145 Shanghai 200127 P R...

Отзывы: