background image

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

BIC IO-Link unidirectional  

500 mA, IP67 

User´s Guide 

English  

 

Содержание BIC 1I0-I2A50-M30MI3-SM4A4A

Страница 1: ...BIC IO Link unidirectional 500 mA IP67 User s Guide English...

Страница 2: ...and diagnosis 5 4 1 Base indicators 5 4 2 Remote indicators 5 5 Installation and Connection 6 5 1 Mutual Interference 6 5 2 Installation in metal 6 5 3 Angular offset 7 5 4 Connection 7 5 5 Series co...

Страница 3: ...ollowing typographical conventions are used in this guide Enumerations Enumerations are shown as a list with an en dash Entry 1 Entry 2 Syntax Numbers Decimal numbers are shown without additional indi...

Страница 4: ...ed the device must be taken out of operation and protected against unauthorized use 2 5 Meaning of the warning notes The warning notices in this guide and the measures described for avoiding dangers m...

Страница 5: ...ansmitted from the remote to the base The energy available for the IO Link device is dependent on the distance and on the offset between base and remote and is therefore limited For this reason the to...

Страница 6: ...nk communication between master and base is OK Red flashing No remote detected Red off Remote present IO Link communication OK Red static Remote present no IO Link communication to connected device 4...

Страница 7: ...SM4A4A 100 BIC 2I0 I2A50 M30MI3 SM4A5A 100 5 2 Installation in metal Caution Device damage due to induction effects Metallic objects on the coil cap cause the objects to be heated Install the compone...

Страница 8: ...g are used To satisfy the EMC requirements the cables must not be longer than 20 meters 5 5 Series connection Two BIC systems can be connected in series Caution This cuts the power in half from 500 mA...

Страница 9: ...orque 70 Nm 6 3 Operating conditions Transmission distance 1 to 5 mm Operating temperature Ta 0 C to 55 C Storage temperature range 25 C to 75 C EMC EN 61000 4 2 3 4 5 6 EN 55011 Severity 4 3 4B 2 3 S...

Страница 10: ...160 g Tightening torque 70 Nm 7 3 Operating conditions Transmission distance 1 to 5 mm Operating temperature Ta 0 C to 55 C Storage temperature range 25 C to 75 C EMC EN 61000 4 2 3 4 5 6 EN 55011 Se...

Страница 11: ...it 2 PD Byte 0 Bit 1 PD Byte 0 Bit 0 Byte 1 7 6 5 4 3 2 1 0 PD Byte 1 Bit 7 PD Byte 1 Bit 6 PD Byte 1 Bit 5 PD Byte 1 Bit 4 PD Byte 1 Bit 3 PD Byte 1 Bit 2 PD Byte 1 Bit 1 PD Byte 1 Bit 0 Byte 2 7 6 5...

Страница 12: ...x 0B 0 x 10 0 Vendor name 7 bytes BALLUFF 0 x 11 0 Vendor text 15 bytes www balluff com 0 x 12 0 Product name 37 bytes BIC 1I0 I2A50 M30MI3 SM4A4A 0 x 13 0 Product ID 7 bytes BIC000C 0 x 14 0 Product...

Страница 13: ...mper BCC M415 M414 3A 304 PX0434 xxx XXX cable length PUR for remote open cable end BCC M415 0000 1A 003 PX0434 xxx XXX cable length 9 2 Installation accessories Description Description Fig BES 30 0 B...

Страница 14: ...uff Inductive Coupler Base 1 Remote 2 Technology PNP variant 24 V power class 500 mA I2 4 bytes Housing shape M30x1 5 Housing material M brass and length SM4A5A Connector M12 axial Number of pins and...

Страница 15: ...E Edition L14 Replaces Edition C12 Subject to modification Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de www balluff com www ballu...

Отзывы: