Operating instructions (safety aspects, ATEX Annex II)
Information on safe use in potentially explosive atmospheres
Function and features
• Use in
potentially explosive atmospheres
according to the classification
(Group II, category 1G/2G, use in
potentially explosive atmo-
spheres
according to the classification).
This device is subject to the standards IEC 60079-0:2011,
EN 60079-11:2012 and EN 60079-26:2007.
• Use in
potentially explosive atmospheres
according to the classification (Group II,
category 1D, apparatus for explosive atmospheres caused by dust).
This device meets the requirements of the standards
IEC 60079-0:2011, EN 60079-11:2012.
• EC type test certificate
• Marking
Installation/commissioning
The units should only be installed, connected and commissioned by qualified
personnel who must be familiar with the protection classes, regulations and
provisions for systems intended for use in potentially explosive atmospheres.
Please ensure that the classification (see "Classification" above and the
labels on the unit) are appropriate for the intended application.
4
IRL
GB
ENGLISH
II 1G / 2G
II 1D
BVS 05 ATEX E 162 X
II 1G Ex ia IIC T6 Ga
II 1D Ex ia IIIC T90°C Da
Ta: –20°C ... +70°C
II 2G Ex ia IIC T6 Gb
II 1G Ex ia IIB T6 Ga
BES M12ME-GNX40B-S04G-EEX
BES M18ME1-GNX80B-S04G-EEX
BES M30ME1-GNX15B-S04G-EEX
BES Q40KFU-GNX20B-S92G-EEX
BES Q40KFU-GNX35F-S92G-EEX
II 2G Ex ia IIB T6 Gb
II 1D Ex ia IIIC T90°C Da
Ta: –20°C ... +70°C
II 1D Ex ia IIIC T90°C Da
Ta: –20°C ... +70°C