20
Continuation
„
SSI Properties
“:
ERROR BIT
Defines the encoder monitoring and the error bit
0
No error bit available.
Review on connected sensor is turned off.
…
32
Position of the error bits to be evaluated
Review on connected sensor is turned on.
ERROR POLARITY
Defined the polarity of the error bit in the case of an error
0
Bit is low in the case of an error
1
Bit is high in the case of an error
ENCODER SUPPLY
This parameter defines the output voltage of the auxiliary output (aux out)
0 24VDC SUPPLY
24 VDC encoder supply
1 5VDC SUPPLY
5 VDC encoder supply