5.8. Command Menu
INPUT 1 ACTION
(function Input 1)
This para
meter defines the function of the input “Ctrl. In 1”.
0
NO
No function
1
RESET/SET
VALUE
Transfer of the current SSI position to the SSI offset parameter
(d) (s)
2
FREEZE
Freeze actual display value
(s)
3
KEY LOCK
disable touch screen
(s)
4
LOCK RELEASE
Loosen locking of all outputs / relay
(d)
5
RESET MIN/MAX
Reset of the min. / max. values
(d) (s)
6
SERIAL PRINT
Sending of serial data, see parameter SERIAL VALUE
(d)
7
TEACH PRESEL. 1
Current display value is stored as PRESELECTION 1
(d)
8
TEACH PRESEL. 2
Current display value is stored as PRESELECTION 2
(d)
9
TEACH PRESEL. 3
Current display value is stored as PRESELECTION 3
(d)
10
TEACH PRESEL. 4
Current display value is stored as PRESELECTION 4
(d)
11
SCROLL DISPLAY
Display switching (see display in operation mode)
(d)
12
CLEAR LOOP
TIME
Release all latched switching conditions
13
START
PRESELECT
N.A.
14
ACTIVATE DATA
N.A.
15
STORE DATA
N.A.
16
TESTPROGRAM
N.A.
17
SET RED COLOR
The display lights up red. The color can be changed by the
event-dependent color switching in the PRESELECTION 1... 4
(d)
18
SET GREEN
COLOR
The display lights up green. The color can be changed by the
event-dependent color switching in the PRESELECTION 1... 4
(d)
19
SET YELLOW
COLOR
The display lights up yellow The color can be changed by the
event-dependent color switching in the PRESELECTION 1... 4
(d)
(s) = static switching (level evaluation)
INPUT CONFIG must be set to active LOW / HIGH
(d) = dynamic switching (edge evaluation)
INPUT CONFIG must be set to RISING/FALLING EDGE