INPUT 1 ACTION
(function Input 1)
This parameter defines the function of the input “Ctrl. In 1”.
0
NO
No function
1
RESET/SET VALUE
Power fail-safe stored transfer of the current position to the
parameter "offset". Example Application: non-volatile setting of the
machine zero point.
(d) (s)
2
FREEZE
Freeze actual display value
(s)
3
KEY LOCK
disable touch screen
(s)
4
LOCK RELEASE
Loosen locking of all outputs / relay
(d)
5
RESET MIN/MAX
Reset of the min. / max. values
(d) (s)
6
SERIAL PRINT
Sending of serial data, see parameter SERIAL VALUE
(d)
7
TEACH PRESEL. 1
Current display value is stored as PRESELECTION 1
(d)
8
TEACH PRESEL. 2
Current display value is stored as PRESELECTION 2
(d)
9
TEACH PRESEL. 3
Current display value is stored as PRESELECTION 3
(d)
10
TEACH PRESEL. 4
Current display value is stored as PRESELECTION 4
(d)
11
SCROLL DISPLAY
Display switching (see display in operation mode)
(d)
12
CLEAR LOOP TIME
N.A.
13
START
PRESELECT
N.A.
14
ACTIVATE DATA
N.A.
15
STORE DATA
N.A.
16
TESTPROGRAM
N.A.
17
SET RED COLOR
The display lights up red. The color can be changed by the event-
dependent color switching in the PRESELECTION 1... 4
(d)
18
SET GREEN
COLOR
The display lights up green. The color can be changed by the event-
dependent color switching in the PRESELECTION 1... 4
(d)
19
SET YELLOW
COLOR
The display lights up yellow The color can be changed by the event-
dependent color switching in the PRESELECTION 1... 4
(d)
20
SET TO REL. ZERO
Measurement is set to 0. The position of the switching points is not
changed. After switched on or by the command STOP SET TO
ZERO, the zero point stored in the offset parameter is valid again.
Sample Application: Relative measurements
(d) (s)
21
SET TO ABS. ZERO
Measurement is set to 0. The position of the switching points is
accordingly moved. After switching on or by the command STOP
SET TO ZERO, the machine zero point stored in the offset parameter
is valid again.
Example Application: setting a reference point
(d) (s)
22
STOP SET TO
ZERO
Any previous zero set (by commands: SET TO REL. ZERO or SET
TO ABS. ZERO) is canceled.
The machine zero point stored in the offset parameter is valid again.
Example application: switch back to absolute measurement after a
relative measurement
(d) (s)
(s) = static switching (level evaluation)
INPUT CONFIG must be set to active LOW / HIGH
(d) = dynamic switching (edge evaluation)
INPUT CONFIG must be set to RISING/FALLING EDGE