16
Continuation
„
General Menu
“:
AVERAGE FILTER
(filter for average value)
The average value can be switched to avoid display fluctuations.
0
No average value
1
Flowing mean value with 2 cycles
2
Flowing average value with 4 cycles
3
Flowing average value with 8 cycles
4
Flowing mean value with 16 cycles
LINEARIZATION MODE
This parameter defines the linearization function. See chapter 6.3.
0
OFF
No linearization
1
1
QUADRANT
Linearization in the 1. quadrant
2
4
QUADRANT
Linearization in all 4 quadrants
PIN PRESELECTION
This parameter defines the PIN-code to lock the quick start of the menu PRESELECTION VALUE for entering
the preselection values
.
(Master PIN 6079).
This Lock function is only useful in conjunction with active lock function in PIN PARAMETER.
0000
No lock
…
9999
Access after entering PIN-Code 9999
PIN PARAMETER
This parameter defines the PIN-code for lock function of all parameters (master PIN 6079).
0000
No lock
…
9999
Parameterization of the unit after entering PIN-code 9999
FACTORY SETTINGS
0
NO
No default values are loaded
1
YES
Load default values of all parameters (grey marked default values)