background image

 

Capacitive Proximity Switches BCS R08RRE…

 

12  

 

Ordering information  

Type code

 

Power amplifier  

PS = PNP N.O. 

PO = PNP N.C. 

NS = NPN  N.O. 

NO = NPN N.C. 

PI = IO-Link

 

Technology 

80 = standard technology

FH = SmartLEVEL  technology

Cable length 

2 = 2m 

0,3 = 0.3 m

Plug 

Empty  = cable connection 

GS75 = M8, 4-pin 

GS04 = M12, 4-pin 

 

Available devices 

Type designation 

Ordering code 

Description 

BCS R08RRE-PSM80C-EP02 

BCS012A 

Standard, PNP N.O., 2 m cable with open end 

BCS R08RRE-POM80C-EP02 

BCS012C 

Standard, PNP N.C.,  2 m cable with open end 

BCS R08RRE-NSM80C-EP02 

BCS012E 

Standard, NPN  N.O., 2 m cable with open end 

BCS R08RRE-NOM80C-EP02 

BCS012F 

Standard, NPN  N.C., 2 m cable with open end 

BCS R08RRE-PSM80C-EP00,3-GS75 

BCS012T 

Standard, PNP N.O., 0.3 m cable with M8 plug, 4-pin 

BCS R08RRE-POM80C-EP00,3-GS75 

BCS012U 

Standard, PNP N.C.,  0.3 m cable with M8 plug, 4-pin 

BCS R08RRE-NSM80C-EP00,3-GS75 

BCS012W 

Standard, NPN  N.O., 0.3 m cable with M8 plug, 4-pin 

BCS R08RRE-NOM80C-EP00,3-GS75 

BCS012Y 

Standard, NPN  N.C., 0.3 m cable with M8 plug, 4-pin 

BCS R08RRE-PSMFHC-EP02 

BCS012H

SmartLEVEL,  PNP N.O., 2 m cable with open end

BCS R08RRE-POMFHC-EP02 

BCS012J 

SmartLEVEL,  PNP N.C.,  2 m cable with open end 

BCS R08RRE-NSMFHC-EP02 

BCS012K 

SmartLEVEL,  NPN  N.O., 2 m cable with open end 

BCS R08RRE-NOMFHC-EP02 

BCS012L 

SmartLEVEL,  NPN  N.C., 2 m cable with open end 

BCS R08RRE-PSMFHC-EP00,3-GS75 

BCS012Z 

SmartLEVEL,  PNP N.O., 0.3 m cable with M8 plug, 4-pin 

BCS R08RRE-POMFHC-EP00,3-GS75 

BCS0130 

SmartLEVEL,  PNP N.C.,  0.3 m cable with M8 plug, 4-pin 

BCS R08RRE-NSMFHC-EP00,3-GS75 

BCS0131 

SmartLEVEL,  NPN  N.O., 0.3 m cable with M8 plug, 4-pin 

BCS R08RRE-NOMFHC-EP00,3-GS75 

BCS0132 

SmartLEVEL,  NPN  N.C., 0.3 m cable with M8 plug, 4-pin 

BCS R08RRE-PIM80C-EP00,3-GS04

BCS012N 

Standard, IO-Link, 0.3 m cable with M12 plug, 4-pin 

BCS R08RRE-PIMFHC-EP00,3-GS04

BCS012P 

SmartLEVEL,  IO-Link, 0.3 m cable with M12 plug, 4-pin 

 

BCS R08RRE 

 PS M 80 C-EP0 0,3 - GS75

 

Содержание BCS R08RRE Series

Страница 1: ...Kapazitive N hrungsschalter BCS R08RRE www balluff com 1 Kapazitive N hrungsschalter BCS R08RRE MicroBox Bedienungsanleitung deutsch...

Страница 2: ...age mit Halter 6 Leckage Anwendung 7 Haltermontage am Rohr 7 Montage mit BALLUFF Montage System 7 Bedienung 8 Bedienelemente 8 Anzeige 8 Abgleich 8 Abgleich bei Objekterkennung 8 Abgleich bei F llstan...

Страница 3: ...LLUFF Zubeh rzugesichert dieVerwendunganderer KomponentenbewirktHaftungsausschluss Ver nderungenamSensorodereine nicht bestimmungsgem e Verwendungsindnicht zul ssigundf hrenzumVerlustvon Gew hrleistun...

Страница 4: ...L Bei IO Link Ger tenstehenzus tzlicheParameter zur Verf gungumdas Verhalten einzustellen siehe KapitelBedienungmitIO Link Anwendungen Beispiele f reinige Anwendungsm glichkeiten sind Objekterkennunga...

Страница 5: ...L Versorgung Minus 4 BK C Q Schaltausgang bzw Kommunikation Wenn m glich sollte der Teach Eingang DI mit der Minusleitung L verbunden werden w Bei SmartLEVEL Ger tendarf das Kabel nicht aufgerolltwer...

Страница 6: ...hStandard Montage sind m glich MaximalesAnzugsdrehmoment0 2 Nm Bei RohrenmitkleinemDurchmesserempfiehlt sichdie Montage mit Kabelbindern Montage mit Halter F r eine schnelle Montage desSensorsverf gtd...

Страница 7: ...berwachungverwendetwerden Dazuwerdendie BefestigungslaschenumgeklapptumdenSensormiteinemAbstandvon2mmzumBodenzu montieren Haltermontage am Rohr Montage mit horizontalemKabelaustritt Montage mit vertik...

Страница 8: ...tindemderEingangDI mitL verbundenwird die bernahme der Schaltschwelle erfolgtbeimEntfernendes EingangsDI vonL Die Art desAbgleichswird berdie Dauerfestgelegt derAblauf wird ber die Funktions LEDangeze...

Страница 9: ...tersindauchim SIO Mode wirksam Schaltausgang im SIO Mode Wennbei IO LinkGer tenkeinMaster angeschlossenistwirdautomatischderSIO Mode verwendet d h dasGer tfunktioniertwie ein SensormitkonventionellerS...

Страница 10: ...inem nichtaggressivenReinigerentferntwerden Entsorgung Eine Instandsetzungdes Ger tsist nicht m glich w Das Ger t istgem der Europ ischen Richtlinien2002 96 EG und2003 108 EG Elektro undElektronik Alt...

Страница 11: ...ard Technologie SmartLEVEL 50 Hz 10 Hz Spannungsabfall 1 5 V Mechanische Daten Umgebungstemperatur 25 70 C Abmessungen L x B x H 34 x 16 x 10 mm Geh usewerkstoff PP Schutzart IP67 Anzugsdrehmoment M3...

Страница 12: ...RE NSM80C EP00 3 GS75 BCS012W Standard NPN Schlie er Kabel 0 3m Stecker M8 4 polig BCS R08RRE NOM80C EP00 3 GS75 BCS012Y Standard NPN ffner Kabel 0 3m Stecker M8 4 polig BCS R08RRE PSMFHC EP02 BCS012H...

Страница 13: ...vice Description IODD sowie weitere InformationenzuIO LinkfindenSie unter www balluff com Ohne IO LinkMasterarbeitenIO Link Ger te im SIO Modus Serial Input Output undverhalten sichwie Ger te mitkonve...

Страница 14: ...Diagnosis UINT16 6 R 0x8004 32772 Teach Channel 0x000E 14 PDInput Descriptor Array Beschreibungder Prozessdaten Oct Str T3 1 R 0x010100 65792 Schaltsignal BDC1 Oct Str T3 1 R 0x020C04 134148 Sensorwer...

Страница 15: ...UINT16 1 R W 0 4095 SchaltpunktSP1 SP2 UINT16 2 R W 0 4095 SchaltpunktSP2 wird nicht verwendet und immer als 0 gelesen 0x003D 61 Switch Point Mode Array Logic UINT8 1 R W 0 Normally Open 1 Normally Cl...

Страница 16: ...stellen Ereignisse Events Event dez Typ Modus Device Status Beschreibung 0xFF91 65425 Meldung einmalig Data Storage Upload Request Ger teparameter wurden ge ndert Anforderung an Master die Parameter z...

Страница 17: ...8RRE www balluff com 17 Balluff GmbH Schurwaldstrasse9 73765 Neuhausen a d F Phone 49 0 71 58 1 73 0 Fax 49 0 71 58 50 10 balluff balluff de www balluff com Dok Nr 917888 726 DE 02 120140 G15 nderunge...

Страница 18: ...Capacitive Proximity Switches BCS R08RRE www balluff com english 1 Capacitive Proximity Switches BCS R08RRE MicroBox User s Guide english...

Страница 19: ...et 6 Leakage application 7 Bracket installation on a tube 7 Installation with BALLUFF installation system 7 Operation 8 Operating elements 8 Display 8 Calibration 8 Calibration for object recognition...

Страница 20: ...tionsinthe technical dataisensured only whenusingoriginal BALLUFFaccessories Use of any othercomponentswill voidthe warranty Modificationstothe sensorornon approveduse are notpermittedandwill resultin...

Страница 21: ...tyreversal Approvals CE UL For IO Linkdevices additional parametersare available forsettingbehavior see section OperationwithIO Link Applications Some example applicationsare Objectdetection Stackingh...

Страница 22: ...Supply negative 4 BK C Q Switchingoutput or communication If possible theteach inputDI should be connected to the negativesupply L w For SmartLEVEL devices the cable mustnot be rolledup If possible s...

Страница 23: ...erse installationandstandardinstallationare possible Maximumtighteningtorque 0 2 Nm For tubeswithsmall diameters we recommend installationusingcable ties Installation with bracket The enclosedbracketf...

Страница 24: ...all the sensorwith adistance of 2 mm fromthe floorfoldthe distance flaps underthe bracketuntil theyclickintothe lockedposition Bracket installation on a tube Installationwith horizontal cableexit Inst...

Страница 25: ...L the switchingthresholdisadoptedwhen removingthe DIinputfromL The type of calibrationisdeterminedbasedonthe duration the processis displayedviathe functionLED see Displayduringcalibration w Full cali...

Страница 26: ...ut in SIO mode If no masteris connectedtoIO Linkdevices they automaticallyuse the SIOmode i e the device functionsasa sensorwitha conventional switchingpoweramplifier Viathe SIOOutput Mode parameter t...

Страница 27: ...E 10 w The device mustbe disposedof inaccordance withthe EuropeanDirectives2002 96 EC and 2003 108 EC Waste Electrical andElectronic Equipment Olddevicesmaynotbe disposed of withhouseholdwaste w Obser...

Страница 28: ...technology SmartLEVEL 50 Hz 10 Hz Voltage drop 1 5 V Mechanical data Ambient temperature 25 to 70 C Dimensions L x W x H 34 x 16 x 10 mm Housingmaterial PP Degree of protection IP67 Tightening torque...

Страница 29: ...RE NSM80C EP00 3 GS75 BCS012W Standard NPN N O 0 3 m cablewith M8 plug 4 pin BCS R08RRE NOM80C EP00 3 GS75 BCS012Y Standard NPN N C 0 3 m cablewith M8 plug 4 pin BCS R08RRE PSMFHC EP02 BCS012H SmartLE...

Страница 30: ...yforconfigurationas well asfurtherinformationat www balluff com Withoutan IO Linkmaster IO Linkdevices operate inthe SIO mode Serial Input Output and behave like deviceswithaconventionaloutput Profile...

Страница 31: ...x8004 32772 Teach Channel 0x000E 14 PDInput Descriptor Array Structure of Process Data Oct Str T3 1 R 0x010100 65792 Switch signal BDC1 Oct Str T3 1 R 0x020C04 134148 Sensor ValuePDV1 0x0010 16 Vendor...

Страница 32: ...6 1 R W 0 4095 SwitchpointSP1 SP2 UINT16 2 R W 0 4095 SwitchpointSP2 is not used and is always read as 0 0x003D 61 Switch Point Mode Array Logic UINT8 1 R W 0 Normally Open 1 Normally Closed default 0...

Страница 33: ...ttings for switchpoint BDC Events Event Type Mode Device Status Description 0xFF91 65425 Notification once Data Storage Upload Request Device Parameters have been changed request master to upload para...

Страница 34: ...8RRE www balluff com 17 Balluff GmbH Schurwaldstrasse9 73765 Neuhausen a d F Phone 49 0 71 58 1 73 0 Fax 49 0 71 58 50 10 balluff balluff de www balluff com Doc no 917888 726 EN 02 120140 G15 Subject...

Отзывы: