www.balluff.com
11
english
6
IO-Link interface (continued)
6.4
Identification parameters
Index
Parameters
Data format (length)
Access
Contents
Hex. Dec.
0010 16
Vendor name
StringT (7 bytes)
Read only
"BALLUFF"
0011 17
Vendor text
StringT (15 bytes)
Read only
"www.balluff.com"
0012 18
Product name
StringT (21 bytes)
Read only
"BAW M12MI-BLC35C-S04G"
0013 19
Product ID
StringT (7 bytes)
Read only
"BAW004M"
0014 20
Product text
StringT (28 bytes)
Read only
"Inductive Positioning System"
0016 22
Hardware revision
StringT (3 bytes)
Read only
"XX"
0017 23
Firmware revision
StringT (8 bytes)
Read only
"vX.XX.XXX"
0018 24
Application specific tag
StringT (max. 32 bytes)
Read/Write ***
Tab. 6-4: IO-Link identification data
Access to subindex 0 addresses the entire
object of an index. Access of subindices >0
addresses the individual elements of an index.
Device Access Locks
With this standard parameter, it is possible to active or
deactivate certain functions of the IO-Link device. With
BAW M12M_-BLC_ _ _-S04G, there is the option to lock
the function of the parameter manager. To do so, bit 1 of
the 2-byte value must be set to "1" (locked). In order to
unlock the parameter manager, bit 1 is set to "0".
Bit
Function
Lock
Supported
Not
supported
0
Parameter access
X
1
Parameter management
X
2
Local parameterization
X
3
Local user interface
X
4…15 Reserved
Tab. 6-5: Lock parameter data
Profile Characteristic
This parameter indicates which profile is supported by the
IO-Link device.
The inductive linear position sensor
BAW M12M_-BLC_ _ _-S04G supports the Smart Sensor
Profile with a process data variable:
– Subindex 1 ("Profile Identifier -> DeviceProfileID"):
0x0001 ("Smart Sensor Profile")
– Subindex 2 ("Profile Identifier -> FunctionClassID"):
0x8000 ("Device Identification Objects")
– Subindex 3 ("Profile Identifier -> FunctionClassID"):
0x8002 ("ProcessDataVariable")
PD Input Descriptor
This parameter describes the composition of the process
data variables used.
The inductive linear position sensor
BAW M12M_-BLC_ _ _-S04G processes the process data
variables (see Tab. 6-6 on page 12).
Application Specific Tag
The
Application Specific Tag
makes it possible to assign
the IO-Link device an arbitrary, 32-byte string. This can
only be used for application-specific identification and
applied in the parameter manager. The entire object is
accessed via subindex 0.
BAW M12MI-BLC35C-S04G and BAW M12MH-BLC70G-S04G
Inductive Linear Position Sensor
Содержание BAW M12MH-BLC70G-S04G
Страница 1: ...BAW M12MH BLC70G S04G BAW M12MI BLC35C S04G Betriebsanleitung deutsch...
Страница 2: ...www balluff com...
Страница 21: ...BAW M12MH BLC70G S04G BAW M12MI BLC35C S04G User s Guide english...
Страница 22: ...www balluff com...
Страница 41: ...BAW M12MH BLC70G S04G BAW M12MI BLC35C S04G Manual de instrucciones espa ol...
Страница 42: ...www balluff com...
Страница 61: ...BAW M12MH BLC70G S04G BAW M12MI BLC35C S04G Notice d utilisation fran ais...
Страница 62: ...www balluff com...
Страница 81: ...BAW M12MH BLC70G S04G BAW M12MI BLC35C S04G Manuale d uso Italiano...
Страница 82: ...www balluff com...