24
Continuation „
Preselection 1 Menu
“:
START UP DELAY 1 (S)
Start-up suppression for the switching condition of preselection 1. Time to start the monitoring
function.
This adjustment is only valid for the switching condition |RESULT|<=|PRES| or RESULT<=PRES
and only for MODE „FREQUENCY“ – Channel A or
MODE: „START/STOP“ + OPERATIONAL MODE:
„SPEED“.
START UP DELAY is set to this parameter, when the frequency is detected as 0 Hz (or at a
velocity of 0 m/s). The monitoring function remains deactivated until the set time has elapsed.
With a setting "60.000", the automatic start override is activated. The monitoring function
remains deactivated until the preset value / switching point is exceeded for the first time.
0.000
No start-up suppression
…
59.999
Start-up suppression in seconds
60.000
Automatic start-up suppression