www.balluff.com
55
Interpretation of the measurement result during angle measurement:
The default setting ("CIRCUMFERENCE (mm) = 100.000" and "ROUND LOOP VALUE =
360", as well as "FACTOR = 1", "DIVIDER = 1" and "ADDITIVE VALUE = 0") corresponds to
an angle output or position output of "0...360" (e.g.: degrees) every 100.000 mm.
Continuation “
Operating modes / OP modes of the Start/Stop interface
”
•
SPEED
(speed measurement)
The speed is recorded and can be converted again into another unit using existing scaling
parameters (Factor, Divider and Additive Value), if desired.
Interpretation of the measurement result during speed measurement:
The default setting ("FACTOR = 1", "DIVIDER = 1" and "ADDITIVE VALUE = 0") corresponds
to a velocity output in meters per second [m/s].
The analog output, the setpoints of the transistor outputs and the
linearization function always refer to the scaled measuring result of the
selected operational mode!