10
BAE PD-VS-014-05
2.2.3
Safety notes for assembly
1. Increased operating ambient temperature - If the system is installed in an enclosed module, then the operating tem-
perature may be higher than the ambient temperature in the room. Therefore, you have to consider to install the
Balluff SmartVision Controller in an area which is compatible with the maximum ambient temperature specified by
the manufacturer.
2. Reduced airflow - The installation of the Balluff SmartVision Controller should be completed in such a way that the
air flow quantity which is required for equipment operation is not impaired.
3. Mechanical load - The Balluff SmartVision Controller assembly should be carried out in such a way that there are no
hazardous operational conditions in the event of uneven mechanical loads.
4. Circuit overload - The connection of the Balluff SmartVision Controller to the supply current and the effect an over-
load of power circuits has on the overcurrent protection device and supply circuit cabling should be checked and
considered carefully. When dealing with this aspect, please carefully check specifically the load information on the
name plate of the device.
5. Reliable grounding - The Balluff SmartVision Controller has to be earthed reliably. It is specifically important to con-
sider the power connection cables and to a lesser degree the direct connections to the sub-circuits (e.g. by using
adapter strips).
2.2.4
Safety notes for operation
1. Please shut down the operating system before disconnecting the Balluff SmartVision Controller from the power sup-
ply in order to prevent any data loss.
2. Create free space in front of and behind the Balluff SmartVision Controller.
2.2.5
Conformity
The Balluff SmartVision Controller conforms to therelevant safety regulations IEC, VDE, and EN. If you have questions
about the validity of the installation in the planned environment, please contact your service representative.