![Balluff BAE SC-TL-F03 Скачать руководство пользователя страница 80](http://html1.mh-extra.com/html/balluff/bae-sc-tl-f03/bae-sc-tl-f03_user-manual_3609618080.webp)
www.balluff.com
20
Continuation „
Mode Start/Stop
“:
CIRCUMFERENCE (mm)
Setting the reference size (in "mm") for an angle measurement.
The distance covered (e.g. circumference) at which the subsequent output value (ROUND LOOP
VALUE) is to be generated must be set here.
(Note: Only for OPERATIONAL MODE: "ANGLE")
00000.001
Smallest value
01000.000
Default value
99999.999
Highest value
ROUND LOOP VALUE
Setting of the desired measured value to be generated when the previous reference value
("CIRCUMFERENCE") is reached.
(Note: Only for OPERATIONAL MODE: "ANGLE")
1
Smallest value
360
Default value
99999999
Highest value
AVERAGE FILTER
–
POSITION
(filter for average value)
The average value can be switched to avoid position fluctuations.
0
No average value
1
Flowing mean value with 2 cycles
2
Flowing average value with 4 cycles
3
Flowing average value with 8 cycles
4
Flowing mean value with 16 cycles
STANDSTILL TIME (s)
This parameter defines the time for standstill definition. If standstill is detected, standstill is
signalled after xx,xx seconds and the start-up suppression is reactivated.
A standstill monitoring can be set in the PRESELECTION MENU.
0,01
Shortest delay time in seconds
…
99,99
Longest delay time in seconds
AVERAGE FILTER
–
SPEED
(filter for average value)
The average value can be switched to avoid velocity fluctuations.
0
No average value
1
Flowing mean value with 2 cycles
2
Flowing average value with 4 cycles
3
Flowing average value with 8 cycles
4
Flowing mean value with 16 cycles