P20 / P32 OPERATIONS MANUAL
Page | 17
TROUBLESHOOTING
TROUBLE
POSSIBLE CAUSE
ACTION
Machine will not start.
1. No electric supply
2. Motor protection tripped
3. Switch broken
4. Low supply voltage
Check fuses and supply cable connections.
Reset. If tripped again, check motor and pump condition.
Check the voltage up to the motor.
Check the voltage.
Motor runs but no
piston movement.
1. Wrong rotation direction
2. Low oil level
3.Fuses/rectifier/ transformer out of order
4.Dial broken (MS)
5. Valve out of order
6.Pump or coupling broken
Interchange two phases in the supply disconnecting device.
Check, refill.
Check, replace.
Check, replace.
Check movability of valve steam. Check the solenoids.
Check, replace
Insufficient crimping force.
1. Insufficient lubrication
2. Low oil level
3. Pressure relief valve stuck
Pilot check valve leaking
4. Leaking pump/pressure pipe
5. Coupling between motor and pump
slipping
Lubricate the dies.
Check, refill.
Check, clean.
Replace if broken.
Check, tighten, replace
Check, replace.
Crimping diameter varies
1. Insufficient lubrication
2. Set value changed
3. Dial knob loose (MS)
4. Dial loose or broken (MS)
5. Valve sticking
Lubricate the dies
Check.
Check, calibrate, tighten
Check, tighten, replace
Check, clean.