background image

1-2 Product Safety Information

MN2417

This symbol is shown throughout the manual to indicate a connection to ground reference point.

 

Symbols

Indicates a potentially hazardous situation which, if not avoided, could result in injury or death.
Indicates a potentially hazardous situation which, if not avoided, could result in injury or death.

Precaution Statements Used In This Manual

There are three classifications of precautionary statements used in this manual.  The most critical

is a 

WARNING

 statement, then the 

Caution

 statement and the least critical is the Note

statement.  The usage of each statement is as follows:

WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in injury or

death.

Caution:

Indicates a potentially hazardous situation which, if not avoided, could result in damage to

property.

Note:

Additional information that is not critical to the installation or operation.

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

 

  

This manual contains important instructions for the generator that

should be followed during installation, operation and maintenance of the generator.

For ease of reading, the Warning statements are divided into four categories: Operation, Burn, Installation,

and Maintenance.

Operation
WARNING: Never allow a person to ride in or on a trailer that is being towed.  All states prohibit

passengers in towed vehicles.  A person can fall off and be struck be another vehicle or run

over by the towed trailer.  Failure to observe this warning can result in death.

WARNING: Before using a tow vehicle with a trailer mounted generator, verify that the vehicle is designed

for the load.  Using a vehicle that is too small is very dangerous.  Be certain that it can handle

the M.G.T.W. (Maximum Gross Trailer Weight) and the tongue weight for safe towing and

braking.

WARNING: For a new trailer, the wheel lug nuts should be tightened to the proper torque specification

before use, after 25 miles of operation and every 100 miles of operation thereafter.  Failure to

check the lug nuts for proper tightness can result in an accident due to a wheel falling from

the trailer.

WARNING: Never operate a trailer or tow vehicle that has a loose, missing or broken lug nut.  The trailer

is designed for safe operation with all lug nuts installed and all at the proper torque rating.

Operating the trailer with one or more broken or missing lug nuts greatly increases the load

on the remaining nuts and can cause failure of the remaining nuts that can result in an

accident due to a wheel falling from the trailer.

WARNING: Never operate this generator in a manner other than as described in this manual.  Operation

in any manner not described in this manual should be considered unsafe and should not be

attempted.  Never start the engine unless you have first verified that the installation and

operation of the generator are as described in this manual.

WARNING: Be sure that you are completely familiar with the safe operation of this equipment.  This

equipment may be connected to other machines that have rotating parts or parts that are

controlled by this equipment.  Improper use can cause serious or fatal injury.

WARNING: Exhaust fumes/gases are extremely dangerous and can cause severe illness or death.  Never

breath exhaust fumes produced by a running engine.  Only run the engine outdoors where

ventilation is plentiful.  Exhaust gases contain carbon monoxide, a colorless, odorless and

extremely dangerous gas that can cause unconsciousness or death.  Symptoms of carbon

monoxide poisoning include: dizziness, nausea, headaches, sleepiness, vomiting or

incoherence.  If you or anyone else experiences these symptoms, get out into fresh air

immediately.  Stop the engine and do not restart the engine until it has been inspected and if

necessary repaired or reinstalled in a well ventilated area.

WARNING: When operating this generator remain alert at all times.  Never operate machinery when

physically or mentally fatigued, or while under the influence of alcohol, drugs or medication.

Continued on next page.

Содержание TS25

Страница 1: ...Tier 2 3 Towable Generators Trailer and Skid Mounted Diesel Liquid Cooled TS25 35 45 60 80 130 175 250 and 400 Installation Operating Manual 8 06 MN2417...

Страница 2: ...hemicals known to the state of California to cause cancer birth defects and other reproductive harm WARNING CALIFORNIA PROPOSITION 65 WARNING Battery posts terminals and related accessories are known...

Страница 3: ...ctions 3 4 Battery Connections 3 7 Recommended Engine Oil and Battery Type 3 9 Post Installation Checks 3 9 Section 4 Operation 4 1 Towing the Generator 4 1 Selecting the Proper Towing Equipment 4 1 S...

Страница 4: ...ii Table of Contents MN2417...

Страница 5: ...e that operates this equipment at all times Keep non qualified personnel at a safe distance from this equipment Only qualified personnel familiar with the safe installation operation and maintenance o...

Страница 6: ...efore use after 25 miles of operation and every 100 miles of operation thereafter Failure to check the lug nuts for proper tightness can result in an accident due to a wheel falling from the trailer W...

Страница 7: ...in water on wet ground or with wet hands feet or shoes or while barefoot WARNING High voltage is present whenever the engine is running Electrical shock can cause serious or fatal injury Always stop...

Страница 8: ...proper grounding of generator systems WARNING Place protective covers over all rotating parts such as drive shaft pulley belt etc Rotating parts cause extremely dangerous situations because they can...

Страница 9: ...wires with damaged insulation immediately Electrical shock can cause serious or fatal injury WARNING Disconnect all electrical wires and load devices from generator power outlets before servicing the...

Страница 10: ...voltage and output frequency Caution Never operate the engine without a muffler The engine is designed to have the correct exhaust components installed and operating without these components can pres...

Страница 11: ...stallation shipment or otherwise Problems with Baldor products can be due to improper maintenance faulty installation non Baldor additions or modifications or other problems not due to defects in Bald...

Страница 12: ...2 2 General Information MN2417...

Страница 13: ...pacity and tires for the terrain to avoid becoming stuck or tipping over If the shipping pallet is intact use a fork lift to move the generator If the shipping pallet has been removed use the Lift Poi...

Страница 14: ...to be opened or removed for service and maintenance 7 Maximum Ambient temperature is 122 F 50 C Figure 3 2 Generator Mounting Skid B1 B A A2 A1 TS130 175 only 4 Holes A2 A1 TS25 45 80 only 3 Holes A1...

Страница 15: ...hat an exhaust rain cap be used whenever it is possible that rain could get into the system This will help to prevent corrosion and damage to the exhaust system and engine Installation The generator i...

Страница 16: ...erator The power output connections are rated and sized according to the KW of the generator Proper lead wire from these points to the automatic transfer switch or load switching device is mandatory S...

Страница 17: ...connections are weather tight Figure 3 3 Receptacle Panel Single Phase Single phase power is always available GOLD X GOLD Y G SILVER W CS6369 125 250V 50A X Y W Test Reset CS6365N GFI Outlet 120V 20A...

Страница 18: ...h may also be used to start the generator Shore Power Use extension cord with appropriately sized conductors to connect the optional Shore Power receptacle to 120VAC 240VAC for TS400 single phase util...

Страница 19: ...nel away from batteries WARNING Do not dispose of battery or batteries in a fire The battery is capable of exploding If the battery explodes electrolyte solution will be released in all directions Bat...

Страница 20: ...battery cables from the battery the negative first then the positive 3 Remove the Battery Hold Down Bar and Rods 4 Remove the old battery and place the correct new battery see Table 3 5 on the tray 5...

Страница 21: ...e generator to the factory for repair and consequent expense and loss of time Note These precautions are especially necessary in locations such as seaboard installations and other high humidity areas...

Страница 22: ...iately and repair the leak before proceeding b Verify there are no coolant or oil leaks If a leak is detected stop the engine set the Master Control in the Stop position immediately and repair the lea...

Страница 23: ...ransport passengers in any trailer S Reduce weight in car trunk and rear seat areas by the amount of tongue weight of your trailer S Any alterations or changes made to the trailer void any express or...

Страница 24: ...nd weather conditions Avoid sudden stops if possible 3 Passing Accelerating and passing should be done slowly to allow extra distance for passing Signal well in advance when passing and returning to t...

Страница 25: ...to drag on ground or roadway 8 Test breakaway system Hydraulic surge brake system normally have a cable or chain connected to the tow vehicle In a break away condition this cable or chain activates t...

Страница 26: ...inflation 13 Check wheel lug nuts for correct tightness see Lug Nut Tightness Wheel nuts bolts should be torqued before the first road use and after each wheel removal Check and re torque after the f...

Страница 27: ...cords or external devices WARNING High voltage is present whenever engine is running Electrical shock can cause serious or fatal injury Never operate electrical equipment while standing in water on w...

Страница 28: ...ctions see Figure 4 4 1 240 120VAC voltage is present at the receptacle panel at all times when generator is running 2 Carefully inspect all Individual load cables for broken insulation or other signs...

Страница 29: ...zer sounds an alarm when operator attention is needed Voltage Select Switch switch Selects 208 120 240 120 or 480 277VAC OFF 1 2 Auto Start Connection for external two wire starting from transfer swit...

Страница 30: ...connected and connections are secure 9 Ensure that an external ground connection is made when required for safety 10 Ensure that the Remote Start wires are properly connected if used 11 Use disconnect...

Страница 31: ...Warning X High Coolant temperature X Low Oil pressure X Low Fuel level X Generator Over Voltage X Generator Over Frequency X Generator Over Current X Generator Overspeed X Coolant temperature High Lo...

Страница 32: ...in Figure 4 7 displays the operating mode and operating parameters such as kW engine RPM etc Figure 4 7 Measurement Menu OFF MAN AUT Ready PF RPM Timer 0 00 0 0 0 kW Control Mode Operating Modes and H...

Страница 33: ...ng RPM 0 or any other shutdown condition READY TO LOAD off FUEL SOLENOID off Shutdown Generator CB Closed Loaded Generator CB Opened Running Loaded RPM 0 or any other shutdown condition FUEL SOLENOID...

Страница 34: ...ut are closed Active or not reset protection disables start Table 4 5 Possible Warnings Events specification Protection type Binary output available Table 4 7 Wrn Oil press WRN YES Sd Oil press SD YES...

Страница 35: ...y energizes the starter motor The relay opens if The firing speed is reached or Maximum time of cranking is exceeded or Request to stop occurs Fuel solenoid relay output Closed output opens the fuel s...

Страница 36: ...is not active and FAULT RESET is pressed Note Treshhold level for D input is 80 supply voltage Vgen failed Output is closed if the generator over under voltage shutdown alarm or voltage asymmetry shu...

Страница 37: ...loses if the generator over under voltage warning alarm activates fgen warning Output closes if the generator over under frequency warning alarm activates Overload wrn Output closes if the generator o...

Страница 38: ...te identification at remote phone or mobile connection Gen set name is max 14 characters long and have to be entered using LiteEdit software Nomin power 3ph Nominal power of the generator in three pha...

Страница 39: ...Step 1s Range 1 60 s CrnkFail pause Pause between crank attempts Step 1s Range 5 60 s Crank attemps Max number of crank attempts Step 1 Range 1 10 Idle time Idle time delay starts when RPM exceeds Sta...

Страница 40: ...etpoint value Eng prot del During the start of the gen set some engine protections have to be blocked e g Oil pressure The protections are unblocked after the Protection del time The time starts after...

Страница 41: ...overvoltage All three phases are checked Maximum out of three is used Step 1 of Nominal voltage Range Gen V Wrn Gen V Gen V Wrn Warning level for generator under voltage All three phases are checked M...

Страница 42: ...3 lev1 The level for IOM ANALOG INPUT 3 alarm detection Step 1 Range 100 to 10000 AnlInIOM3 lev2 The level for IOM ANALOG INPUT 3 alarm detection Step 1 Range 100 to 10000 AnlInIOM3 del Delay for IOM...

Страница 43: ...NOID L1 L2 L3 N Generator C B ANALOG INPUTS BINARY OUTPUTS RPM RPM IN COM BO6 BO3 BO4 BO5 BO1 START BO2 FUEL AI1 OIL AI2 TEMP AI3 FUEL RPM GND POWER 8 36 V DC EXTENSION MODULES GENERATOR CURRENT GENER...

Страница 44: ...er at o r C B PRESTART PE RS 232C Int erface Modem or PC C O NT RO L SI GNALS ALARM RE ADY TO L OA D D CHRG ALT ER NATOR BINARY INP UTS RPM RPM IN COM BO3 BO4 BO5 BO6 BO1 START BO2 FUEL AI1 OIL AI2 T...

Страница 45: ...air filters per the engine manufacturers guidelines 2 Check oil level regularly at least every 5 to 8 operating hours Maintain the proper oil level 3 Change the oil as is recommended in the engine ma...

Страница 46: ...e voltage meter with an accurate voltmeter to verify Check continuity across Breaker Fuse Replace if defective Check wiring including grounds crimps and connection points Repair defects The generator...

Страница 47: ...gher than rear of tow vehicle when additional supports have been removed View and make adjustments while vehicle and trailer are on level surface Seek expert advise Reduce tow vehicle speed and use ca...

Страница 48: ...5 4 Troubleshooting and Maintenance MN2417...

Страница 49: ...tified in the engine manual that was provided with your generator set IMPORTANT Fuses are installed in the control box to protect the engine controller and associated control circuits When replacing f...

Страница 50: ...A 2 Wiring Diagrams MN2417 Figure A 1 TS25 Connection Diagram...

Страница 51: ...Wiring Diagrams A 3 MN2417 Figure A 2 TS25 Connection Diagram...

Страница 52: ...A 4 Wiring Diagrams MN2417 Figure A 3 TS25 Connection Diagram...

Страница 53: ...Wiring Diagrams A 5 MN2417 Figure A 4 TS25 Connection Diagram...

Страница 54: ...A 6 Wiring Diagrams MN2417 Figure A 5 TS25 Connection Diagram...

Страница 55: ...Wiring Diagrams A 7 MN2417 Figure A 6 TS25 Connection Diagram...

Страница 56: ...A 8 Wiring Diagrams MN2417 Figure A 7 TS35 Connection Diagram...

Страница 57: ...Wiring Diagrams A 9 MN2417 Figure A 8 TS35 Connection Diagram...

Страница 58: ...A 10 Wiring Diagrams MN2417 Figure A 9 TS35 Connection Diagram...

Страница 59: ...Wiring Diagrams A 11 MN2417 Figure A 10 TS35 Connection Diagram...

Страница 60: ...A 12 Wiring Diagrams MN2417 Figure A 11 TS35 Connection Diagram...

Страница 61: ...Wiring Diagrams A 13 MN2417 Figure A 12 TS35 Connection Diagram...

Страница 62: ...A 14 Wiring Diagrams MN2417 Figure A 13 TS35 Power Connection Diagram...

Страница 63: ...Wiring Diagrams A 15 MN2417 Figure A 14 TS60 Connection Diagram...

Страница 64: ...A 16 Wiring Diagrams MN2417 Figure A 15 TS60 Connection Diagram...

Страница 65: ...Wiring Diagrams A 17 MN2417 Figure A 16 TS60 Connection Diagram...

Страница 66: ...A 18 Wiring Diagrams MN2417 Figure A 17 TS60 Connection Diagram...

Страница 67: ...Wiring Diagrams A 19 MN2417 Figure A 18 TS60 Connection Diagram...

Страница 68: ...A 20 Wiring Diagrams MN2417 Figure A 19 TS60 Connection Diagram...

Страница 69: ...Wiring Diagrams A 21 MN2417 Figure A 20 TS60 Connection Diagram...

Страница 70: ...A 22 Wiring Diagrams MN2417 Figure A 21 TS80 Connection Diagram...

Страница 71: ...Wiring Diagrams A 23 MN2417 Figure A 22 TS80 Connection Diagram...

Страница 72: ...A 24 Wiring Diagrams MN2417 Figure A 23 TS80 Connection Diagram...

Страница 73: ...Wiring Diagrams A 25 MN2417 Figure A 24 TS80 Connection Diagram...

Страница 74: ...A 26 Wiring Diagrams MN2417 Figure A 25 TS80 Connection Diagram...

Страница 75: ...Wiring Diagrams A 27 MN2417 Figure A 26 TS80 Connection Diagram...

Страница 76: ...A 28 Wiring Diagrams MN2417 Figure A 27 TS80 Connection Diagram...

Страница 77: ...Wiring Diagrams A 29 MN2417 Figure A 28 TS80 Connection Diagram...

Страница 78: ...A 30 Wiring Diagrams MN2417 Figure A 29 TS80 Connection Diagram...

Страница 79: ...Wiring Diagrams A 31 MN2417 Figure A 30 TS80 Connection Diagram...

Страница 80: ...A 32 Wiring Diagrams MN2417 Figure A 31 TS400 Connection Diagram...

Страница 81: ...Wiring Diagrams A 33 MN2417 Figure A 32 TS400 Connection Diagram...

Страница 82: ...A 34 Wiring Diagrams MN2417 Figure A 33 TS400 Connection Diagram...

Страница 83: ...Wiring Diagrams A 35 MN2417 Figure A 34 TS400 Connection Diagram...

Страница 84: ...A 36 Wiring Diagrams MN2417 Figure A 35 TS400 Connection Diagram...

Страница 85: ...Wiring Diagrams A 37 MN2417 Figure A 36 TS400 Connection Diagram...

Страница 86: ...A 38 Wiring Diagrams MN2417 Figure A 37 TS400 Connection Diagram...

Страница 87: ...Wiring Diagrams A 39 MN2417 Figure A 38 TS400 Connection Diagram...

Страница 88: ...A 40 Wiring Diagrams MN2417 Figure A 39 TS400 Connection Diagram...

Страница 89: ...Baldor District Offices...

Страница 90: ...e of California to cause cancer birth defects and other reproductive harm WARNING CALIFORNIA PROPOSITION 65 WARNING Battery posts terminals and related accessories are known to the state of California...

Отзывы: