Baldor PG 6000 Скачать руководство пользователя страница 7

Product Safety Information 1‐3

MN2418

Operation Warning Statements

  Continued

WARNING: Be sure that you understand how to stop the engine quickly in case of an emergency situation.

Become familiar with the controls and safety systems provided with this generator set.

WARNING: Always wear safety glasses with side shields and hearing protection when working near the

generator.

WARNING: Improper operation may cause violent motion of connected equipment.  Be certain that

unexpected movement will not cause injury to personnel or damage to equipment.

WARNING: Never operate the generator set indoors or in a poorly ventilated area such as a tunnel or

cave.  Exhaust fumes are extremely dangerous to all personnel that are in or in contact with
that area.

WARNING: Never permit anyone to operate the generator without proper instructions.  Be sure to keep a

copy of this manual with the generator so that all users can be properly informed of its safe
operation.

WARNING: Never allow children or pets to be in the area where the generator is running.  The generator

and the equipment being powered by the generator may cause injury or death.

WARNING: Never operate the generator unless all guards, covers, shields and other safety items are

properly installed.

WARNING: Do not put hands, feet, tools clothing or other objects near rotating parts such as drive shaft,

pulley, belt etc.  Rotating parts cause extremely dangerous situations because they can catch
loose clothing or extremities and cause serious or fatal injury.

WARNING: When operating this generator remain alert at all times.  Never operate machinery when

physically or mentally fatigued, or while under the influence of alcohol, drugs or medication.

WARNING: Never operate the engine when the air cleaner is removed.  An engine backfire can cause

serious burns.

WARNING: High voltage is present whenever engine is running.  Electrical shock can cause serious or

fatal injury.  Never operate electrical equipment while standing in water, on wet ground or with
wet hands, feet or shoes or while barefoot.

WARNING: High voltage is present whenever the engine is running.  Electrical shock can cause serious

or fatal injury.  Always stop engine before connecting or disconnecting power cords or
external devices.

WARNING: Do not smoke near generator during operation or while refueling.  Gasoline and diesel fuel are

flammable and can cause fire, explosions, injury or death.

WARNING: Stop engine and allow engine to cool before refueling.  Gasoline and diesel fuel are flammable

and can cause fire, explosions, injury or death.

WARNING: Never store the generator with fuel in the tank.  Never store the generator indoors or in an

enclosed area or in a poorly ventilated enclosure where fumes may reach an open flame,
electrical spark or pilot light as on a furnace, water heater, clothes dryer, etc.  Gasoline and
diesel fuel are flammable and can cause fire, explosions, injury or death.

WARNING: Allow generator to cool before transporting it or storing it.  Always drain fuel from tank after

generator has cooled.

WARNING: When transporting the generator (especially over rough roads) always drain the fuel tank to

prevent leakage or spillage of fuel.  Gasoline and diesel fuel are flammable and can cause fire,
explosions, injury or death.

WARNING: Operate the generator only on a level surface.  If the generator is tilted during operation, fuel

spillage may result.  Gasoline and diesel fuel are flammable and can cause fire, explosions,
injury or death.

WARNING: Keep generator at least three feet away from buildings and other structures.
WARNING: Keep generator away from flammable or hazardous materials (trash, rags, lubricants,

explosives, paints etc.) and grass or leaf build up.

WARNING: Keep a fire extinguisher near the generator while generator is in use.  An extinguisher rated

“ABC” by the National Fire Protection Association is appropriate.

Continued on next page.

Содержание PG 6000

Страница 1: ...PG 6000 Generator Installation Operating Manual 8 06 MN2418...

Страница 2: ...hemicals known to the state of California to cause cancer birth defects and other reproductive harm WARNING CALIFORNIA PROPOSITION 65 WARNING Battery posts terminals and related accessories are known...

Страница 3: ...3 1 Storage 3 1 Physical Location 3 2 Installation 3 2 Electrical Connections 3 2 Frame Ground Connection 3 3 Engine Oil 3 4 Recommended Engine Oil 3 4 Use of Electric Motor Loads 3 4 Optional Wheel K...

Страница 4: ...ii Table of Contents MN2418...

Страница 5: ...uipment at all times Keep non qualified personnel at a safe distance from this equipment Only qualified personnel familiar with the safe installation operation and maintenance of this device should at...

Страница 6: ...should not be attempted Never start the engine unless you have first verified that the installation and operation of the generator are as described in this manual WARNING Be sure that you are complete...

Страница 7: ...t whenever engine is running Electrical shock can cause serious or fatal injury Never operate electrical equipment while standing in water on wet ground or with wet hands feet or shoes or while barefo...

Страница 8: ...extremities and cause serious or fatal injury WARNING Unauthorized modification of a generator set may make the unit unsafe for operation or may impair the operation of the unit Never start a generato...

Страница 9: ...nk indoors or in an enclosed poorly ventilated area where gasoline fumes could reach an ignition source and cause an explosion Caution Statements Caution The brass connecting tab on some 120VAC duplex...

Страница 10: ...1 6 Product Safety Information MN2418...

Страница 11: ...nstallation shipment or otherwise Problems with Baldor products can be due to improper maintenance faulty installation non Baldor additions or modifications or other problems not due to defects in Bal...

Страница 12: ...2 2 General Information MN2418...

Страница 13: ...ad the following guidelines prior to storing the unit 1 Remove all fuel from the engine s fuel tank 2 Start the generator set and allow it to run out of fuel 3 Close all the fuel valves Note An altern...

Страница 14: ...se severe illness or death Never breath exhaust fumes produced by a running engine Only run the engine outdoors where ventilation is plentiful Exhaust gases contain carbon monoxide a colorless odorles...

Страница 15: ...he generator to the load The gauge of the wire will depend on the distance to the load the permissible voltage drop at the load and the current required by the load If you are not sure of the gauge wi...

Страница 16: ...ch more current amperes to start them than to keep them running Some motors particularly split phase motors are very difficult to start and require 5 to 7 times more current to start them Repulsion in...

Страница 17: ...censed electrician has installed an approved transfer switch Multiple receptacles may be used at the same time provided the total electrical load does not exceed the generators rated output 120Volts P...

Страница 18: ...rope to snap back into the recoil housing Note If the engine does not start after several attempts smell for fuel near the air cleaner If there is a significant gasoline smell coming from the air clea...

Страница 19: ...er s manual 4 Replace the spark plug s as is recommended by the engine manufacturer 5 Clean the cooling fins on the engine to keep the engine s heat dissipation potential at it s maximum 6 Inspect and...

Страница 20: ...orque of terminals Replace worn bearing Low output voltage Low engine speed Excessive load High resistance connections connections will be warm or hot Shorted field Low power factor Check that the Aut...

Страница 21: ...replacing a receptacle inspect the brass tab that normally links both receptacles If it is removed be sure to remove the brass tab from the replacement receptacle before it is installed Failure to re...

Страница 22: ...A 2 PowerchiefR Series MN2418 Figure A 2 PG6000 Wiring Diagram...

Страница 23: ...arranty on EVAP emission related parts is as follows Any warranted part that is not scheduled for replacement as required maintenance in the written instructions supplied is warranted for the warranty...

Страница 24: ...this product contains chemicals known to the state of California to cause cancer birth defects and other reproductive harm WARNING CALIFORNIA PROPOSITION 65 WARNING Battery posts terminals and related...

Страница 25: ...Baldor District Offices...

Страница 26: ...he state of California to cause cancer birth defects and other reproductive harm WARNING CALIFORNIA PROPOSITION 65 WARNING Battery posts terminals and related accessories are known to the state of Cal...

Отзывы: