background image

Page 5

55370_97_A

G

C

G

C

G

C

G

C

RED AC

WHT AC

T

BLK AC

J32

J61

T1

SWITCHBANK A

J11

J66 J65

J15

J16

J25

J63 J64

J33 J34

J36

J37

J35

BALBOA INSTRUMENTS, INC.

VS500Z
P/N  22972 REV D

MADE IN U.S.A

COPYRIGHT 2005

S1

J6

J7

J8

J44

J60

J22

U4

HTR2

HTR1

J101

J100

TB1

FUSE .3A 250V

FUSE 20A 250

FUSE 3A 250V

E

.GN

D

CLASS G   FUSE 30A

F5

F4

K6

K1

K8

K9

K5

J23

J74

J73

J46J46

F1

J29

J47

J50

F7

J17

/26

J20

J1A

J10

J13

J2A

EXT.

RLY

TST

AUX. F

SEN. A

SEN. B

VAC

W1

W7

W10

J1

J2

W2

W3

G

C

W4

K4

K2

K3

Balboa

F2

J12

1

2 3

J43

2-SPD 

EXT RLY

J1

8

TORQUE
RANGE 
FOR TB1:
27-30 IN. LBS.

H

OT

BLA

C

K

N

EUTRA

L

WHITE

H

OT

RED

G

C

VS5xxS mode

1-Spd P2

4.0 kW

Heater rated @ 240V
(Approx. 1kW @ 120V)

Audio VisualAudio Visual

Circ.Pump

Ozone

Ozone and Circ Pump must be same voltage.
DIP switch A9 must be ON if Circ Pump is installed.
Do not remove Fuse F7 (20A)

12V 

Light

2-Spd P1

PCBA Rev D & E only.
Black jumper required.
Do not remove.

Wiring Configuration and DIP Settings

Setup 1 (As Manufactured)

s 60UMP3PEED
s 60UMP3PEED
s 6/ZONE

s 63PA,IGHT
s 6!<6

(Stereo)

s 6K7(EATER

s 6,3-AIN0ANEL
s 6#IRC0UMP/PTIONAL 

A1, Test Mode OFF

A2, See Table 1
A3, J17/26 Pump Disabled

A5, N/A when A9 is OFF

A10, See Table 1

A7, Exp Board Equip Disabled

Panel Button Assignments

1=Mode
2=Temp Up
3=Temp Down
4=Light

5=Pump 1
6=Unused
7=Unused

Panel Button Positions

4

5

6

7

1

2

3

4

7

6

5

2

3

1

100

93
39

SSID #

VS51x/VS5xxS/VS5xxD

Compatible

J12

1

2

3

Memory
Reset

J43

A3, J17/26 Pump Enabled

5=Pump 1
6=J17/26
7=Unused

5=Pump 1
6=Pump 2
7=Unused

120 Volt Connections

240 Volt Connections

Black AC Jumpers 

12 Volt Connections

Relay Control Wires

Wiring Color Key

Typically Line voltage

Typically Line voltage for 2-speed pumps

Neutral (Common)

Ground

Note flat sides in connector

Board Connector Key

1

2

3

4

WARNING: 

Main Power to system should be turned OFF BEFORE adjusting DIP switches.

WARNING: 

Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page)

Содержание VS504SZ

Страница 1: ...A pdf 01 15 2008 Template used 40600_N pdf 11 12 2007 Balboa Instruments System PN 55370 System Model VSP VS504SZ DCAJ Software Version 39 EPN 2684 Base PCBA PN 54638 PCB VS500Z PN 22972 Rev C or D Ba...

Страница 2: ...Page 2 55370_97_A System Revision History System PN EPN Date Requested By Changes Made 55370 2684 01 15 2008 Balboa New system...

Страница 3: ...OT NEUTRAL GROUND System Outputs BALBOA INSTRUMENTS INC VS500Z P N 22972 REV D MADE IN U S A COPYRIGHT 2005 J7 J8 J44 J60 J22 U4 FUSE K8 K5 J1A J10 J13 J2A EXT RLY AUX F SEN A SEN B VAC J1 J2 W2 W3 J1...

Страница 4: ...at is a VS511SZ at version 38 s Displayed next is indicating the system is configured for a heater between 3 and 6 kW or indicating the system is configured for a heater effectively between 1 and 3 kW...

Страница 5: ...uired Do not remove Wiring Configuration and DIP Settings Setup 1 As Manufactured s 6 0UMP 3PEED s 6 0UMP 3PEED s 6 ZONE s 6 3PA IGHT s 6 6 Stereo s 6 K7 EATER s 6 3 AIN 0ANEL s 6 IRC 0UMP PTIONAL A1...

Страница 6: ...ing filter cycles only Panel with button layout is not compatible SSID 100 93 39 41 WARNING sSetting DIP switches incorrectly may cause abnormal system behavior and or damage to system components sRef...

Страница 7: ...9 See the ratings table on the wiring diagram attached to the cover of the enclosure for the configured voltage For 240V output W2 connects to Red AC and for 120V output W2 connects to White AC The vo...

Страница 8: ...d 7 Digital System Jets 1 Jets 2 Light Mode Warm Cool Heat VL701S Serial Standard PN 52298 01 with No Overlay Example shown s Connects to Main Board terminal J1 only Panels with back lighting bulbs in...

Отзывы: