Initial Start-up

When your spa is first actuated, it will go into Priming mode, indicated by “

.”

Please see the M-7 Installation Instruction 

Manual for complete instructions on Power-up and Pump Priming

.

The Priming mode will last for less than 5 minutes and 

then the spa will begin to heat the spa and maintain the water temperature in the Standard mode.

Temp/Set (80°F - 104°F / 26°C - 40°C)

The start-up temperature is set at 100F°/37°C. The 
last measured temperature is constantly displayed on 
the LCD.

Note that the last measured spa temperature displayed is 

current only when the pump has been running for at least 

2 minutes.

To display the set temperature, press the “Temp” or “Set” 
pad once.
To change the set temperature, press the pad a second 
time before the LCD stops flashing. Each press of the 
“Temp” or “Set” pad will continue to either raise or 
lower the set temperature.
If the opposite direction is desired, release the pad and 
let the display revert to the current water temperature. 
Press the pad to display the set temperature, and again 
to make the temperature change in the desired direction.
After three seconds, the LCD will stop flashing and 
display the current spa temperature.

Jets

Touch the “Jets” button once to activate the low speed 
of the pump and again for the high speed. Press the 
“Jets” button again to turn off the pump. If left running, 
the low speed of the pump will automatically turn off 
after 4 hours, and the high speed will automatically 
turn off after 15 minutes. The low speed of the pump 
runs when the blower is on. It may also activate for 
at least 2 minutes every 30 minutes to detect the spa 
temperature and then to heat to the set temperature if 
needed, depending upon mode. When the low speed 
turns on automatically, it cannot be deactivated from the 
panel; however, the high speed may be started.

Jets 2

This button is used to turn pump 2 on and off. If left on, 
the pump automatically turns off after 15 minutes.

Light

Press the “Light” button to turn the light on and off. If 
left on, the light automatically turns off after 4 hours.

Mode

Mode is changed by pressing the “Temp” or “Set” button, 
then pressing the “Light” button.

Standard Mode

 is programmed to maintain the desired 

temperature. Note that the last measured spa temperature 
displayed is current only when the pump has been 
running for at least 2 minutes. “

” will be displayed 

momentarily when you switch into Standard Mode.

Economy Mode

 heats the spa to the set temperature 

only during filter cycles. “

” will display solid when 

temperature is not current, and will alternate with 
temperature when temperature is current.

Sleep Mode 

heats the spa to within 20°F of the set 

temperature only during filter cycles. “

” will display 

solid when temperature is not current, and will alternate 
with temperature when temperature is current.

Preset Filter Cycles

The first filter cycle begins 6 minutes after the spa is 
energized. The second filter cycle begins 12 hours later. 
Filter duration is programmable for 2, 4, 6, 8 hours or for 
continuous filtration (indicated by “

”). The default filter 

time is 2 hours.
To program, press “Temp” or “Set,” then “Jets.” 
Press “Temp” or “Set” to adjust. Press “Jets” to 
exit programming.
The blower purges for 30 seconds at the beginning of 
each filter cycle. The low speed of the pump runs during 
filtration and the ozone generator (if installed) will 
be enabled.

Freeze Protection

If the temperature sensors detect a drop to below 
45°F within the heater, the pump and blower will 
automatically activate to provide freeze protection. The 
equipment stays on until 4 minutes after the sensors 
detect that the spa temperature has risen to 45°F or 
higher. In colder climates, an optional additional freeze 
sensor may be added to protect against freeze conditions 
that may not be sensed by the standard sensors. Aux 
freeze sensor protection acts similarly except with the 
temperature thresholds determined by the switch and 
without a 4-minute delay in turnoff. See your dealer 
for details.