ELECTRONIC CONTROL BOX, 4 FUNCTIONS 20-0244 

 

Specifications 

Rated voltage: 

230 V, 50/60 Hz, single phase 

Rated power: 

3680 W  

Rated current: 

16 A 

The outlets A, B, C and D can individually be loaded with up to max 3680W @ 16A each. However the total sum 
of the loads must not exceed the rated power and current.  
 

Dimensions & temperature 

Weight:  

0.5 kg  

 

 

 

 

Length: 

180 mm 

 

Width: 

105 mm 

Depth: 

75 mm 

Operating temperature:  0 to 50°C 
Storage temperature: 

-20 to 50°C 

 

Important 

This control box is not suitable for medical use. Follow the directions for installation and connection. We reserve 
the right to change the product and the specification without notice.  
 

Safety rules 

A. 

Locate the box in a dry area with good ventilation. 

B. 

The box must be situated at least 3 cm above the ground floor. 

C. 

Before cleaning, servicing, exchanging of parts or accessories or checking up on various disturbances, the 
mains have to be cut off. 

D. 

Make sure that there are no unconnected wires and cables inside the box. 

E. 

Cables and wires must be as short as possible inside and outside the box. 

F. 

The  box  is  protection  Class  I.  It  has  to  be  connected  with  cables  according  to  the  instructions  from  EN 
60335-1 and EN 60335-2-60. It is recommended that you consult a state registered electrician. The supply 
cable has to be minimum type H05VV-F; 3G1.5 mm

2

G. 

Keep at all time minimum 20 mm distance between high and low power cables. 

H. 

In order to separate the box from the mains you must install a suitable ground fault circuit interrupter with at 
least 3 mm break distance on each terminal in the present electrical installation. 

I. 

The mounting is to be made in such a way that it is not possible to touch the electric parts. 

J. 

The electric parts have to be mounted in such a way that they cannot fall into the bathtub. 

K. 

Instruments of Class I must be connected to a permanent installation. 

L. 

Be aware that some countries have requirements about power indication. 

M. 

Tighten all cable glands sufficient by means of a tool to ensure that the Ingres protection is IPX5 and to 
ensure that the cables are fixed in position and protected for physical traction and pressure. 

N. 

If not all cable outlets are used, the cable gland(s) in question has to be changed to dummy plug(s) of the 
same dimension to ensure that the Ingres Protection still is IPX5. 

O. 

This appliance is not intended for use by persons, including children with reduced physical, sensory or 
mental capabilities or lack of experience and knowledge, unless they have been given supervision or in-
struction concerning use of the appliance by a responsible for their safety. 

P. 

Children should be supervised to ensure that they do not play with the appliance.  

 

How to mount cable onto cable gland 

1. Pull the cable through A. 
2. Pull the cable through B and C (B is    
    normally placed inside C). 
3. Tighten A sufficient onto C by means of a  
    tool. 
4. Mount the spade- and eye shoes onto  
    wire ends where this is necessary. 
 
 

 

49-20-0244, 

www.hydroair.dk

, March 2009 

 

1/8 

Содержание Hydro Air 20-0244

Страница 1: ...ables H In order to separate the box from the mains you must install a suitable ground fault circuit interrupter with at least 3 mm break distance on each terminal in the present electrical installation I The mounting is to be made in such a way that it is not possible to touch the electric parts J The electric parts have to be mounted in such a way that they cannot fall into the bathtub K Instrum...

Страница 2: ...ing program active X2 Water level output C Correct water level is re quired for activation Operation independent of water level X3 Timer C 30 minutes timer 30 minutes timer do not run continuously X4 Output D dependency of output A Output A pump must be active before output can be activated Output D can be controlled independently of output A Functional description The bathtub is filled with water...

Страница 3: ... der Stromzufuhr zu trennen ist ein entsprechender FI Schalter zu installieren der mindestens 3 mm Abstand zu jedem Anschlusselement der bestehenden Elektroinstallation hat I Die Montage muss so erfolgen dass es nicht möglich ist mit elektrischen Bauteilen in Berührung zu kommen J Die Elektronischen Bauteile müssen so montiert werden dass sie keinesfalls in die Wanne fallen können K Geräte der Kla...

Страница 4: ... die Aktivierung ist die richtige Wasserstandshöhe erforderlich Funktionsfähig unabhängig vom Wasser stand X3 Zeitschaltuhr C 30 Minuten Zeitschaltuhr 30 Minuten Zeitschaltuhr X4 Ausgang D in Abhän gigkeit von Ausgang A Ausgang A Pumpe muss in Be trieb sein bevor dieser Ausgang genutzt werden kann Ausgang D kann unabhängig von Aus gang A betrieben werden Funktionsbeschreibung Die Bedienung ist nur...

Страница 5: ...ntation haute et basse tension H Pour séparer le boîtier du secteur vous devez installer un disjoncteur de fuite à la terre approprié avec une distance disruptive minimale de 3 mm sur chaque borne dans l installation électrique actuelle I Le montage doit être effectué de manière à éviter tout contact avec les composants électriques J Les composants électriques doivent être montés de manière à ce q...

Страница 6: ...t est requis pour l activation Fonctionnement indépendant du niveau d eau X3 Minuterie sortie C Minuterie de 30 minutes Minuterie de 30 minutes X4 Sortie D dépendante de la sortie A La sortie A pompe doit être active avant de pouvoir activer la sortie La sortie D peut être contrôlée indépendamment de la sortie A Description fonctionnelle La baignoire est remplie d eau jusqu à couvrir au moins la m...

Страница 7: ...elinstallatør Tilslut ningskablet skal som minimum være type H05VV F 3G1 5 mm 2 G Der skal være en afstand på mindst 20 mm mellem stærk og svagstrømskabler H Boksen skal adskilles fra nettet af en kontakt med en brydeafstand på min 3 mm på hver pol I Installeringen skal foretages således at det ikke er muligt for brugeren at berøre elførende dele J Alle elektriske dele skal være således monteret a...

Страница 8: ...X2 Niveau udgang C Aktivering er betinget af korrekt vand niveau Kan betjenes uafhængigt af vandni veauet X3 Timer C 30 min timer 30 min timer X4 Udgang D betinget af A Udgang A pumpe skal være aktiv før udgang D kan benyttes anvendes ved varme eller ozonator Udgang D kan betjenes uafhængigt af udgang A Funktionsbeskrivelse Karret fyldes således at vandniveauet mindst dækker halvdelen af sensorens...

Отзывы: