background image

Page 6

54371-03_97_A

Base Model VS500SZ-VS501SZ-VS510SZ

DIP Switches and Jumpers Definitions

DIP Switches and Jumpers Definitions

DIP Switch Key

 

A1  Test Mode (normally OFF)

 A2+A10   

Control amp draw requirements (See Table 1)

 

A3  “ON” position: off-board pump enabled *

 

  “OFF” position: off-board pump disabled

 

A4  Aux Freeze (must be OFF)

  A5+A9  Pump 1 speeds and Circ Modes:

A5

A9

Circ Mode

Pump 1 Speed

OFF

OFF

Non-circ

2-speed

ON

OFF

Circ "acts like Pump 1 low" (filters/polls/ect)

1-speed

OFF

ON

24 hours with 3°F shut-off

1-speed

ON

ON

24 hours with 3°F shut-off

2-speed

 

A6  “ON” position: 50Hz operation

 

  “OFF” position: 60Hz operation

 

A7  “ON” position: J17/26 equipment enabled *

 

  “OFF” position: J17/26 equipment disabled

 

A8  “ON” position: temperature is displayed in degrees Celsius

 

  “OFF” position: temperature is displayed in degrees Fahrenheit

* Panel with button layout 

 is not compatible when both A3 and A7 are ON.

SSID 100 65 51

WARNING:

• 

Setting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components.

• 

Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system.

• 

Contact Balboa if you require additional configuration pages added to this tech sheet.

A3: OFF

A7: OFF

Panel Button Positions

Aux Panel Information

Panel Button Assignments

A3:ON

1=Mode
2=Temp Up
3=Temp Down
4=Light
5=Pump 1

Supports 2-button aux panel

VX20

Supports 4-button aux panel

VX40S

6=Unused
7=Unused
6=Pump 2
7=Unused

A7: ON

6=J17/26
7=Unused
6=Pump 2
7=J17/26

7

5

6

4

1

2

3

7

4

5

5

6

7

4

6

6

5

2

3

1

5

6

4

3

2

1

Table 1 

# of Hi-Speed

  

Pumps/Blower

   

Before Heat Disabled

 A2 

A10 

 OFF 

OFF 

0

 ON 

OFF 

1

 OFF 

ON 

2

 ON 

ON 

3

Jumper Key 

J12 

 

Factory set.  DO NOT MOVE.

 

  Jumper must be on Pins 1 and 2 for VS51xZ/VS5xxSZ/VS5xxDZ software.

 

  Jumper must be on Pins 2 and 3 for VS50xZ software.

J43

    When jumper is placed on 2 pins during power-up, system will reset persistent memory.

 

  Leave on 1 pin only to enable persistent memory feature.

Содержание VSP-VS510SZ-DCAH

Страница 1: ...07 11 2011 Template used 40600_P pdf 01 07 2008 Balboa Instruments System PN 54371 03 System Model VSP VS510SZ DCAH Software Version 51 EPN 3609 Base PCBA PN 54372 03 PCB VS500Z PN 22972 Rev C or D Ba...

Страница 2: ...ry System PN EPN Date Requested By Changes Made 54371 01 1801 08 09 2006 Balboa n a 54371 02 2765 04 14 2008 Balboa Software update to v43 54371 03 3609 07 11 2011 BWG Reduce poll duration from 2 minu...

Страница 3: ...d System Outputs BALBOA INSTRUMENTS INC VS500Z P N 22972 REV D MADE IN U S A COPYRIGHT 2005 J7 J8 J44 J60 J22 U4 FUSE K8 K5 J1A J10 J13 J2A EXT RLY AUX F SEN A SEN B VAC J1 J2 W2 W3 J12 1 2 3 2 SPD EX...

Страница 4: ...system For example if these three numbers are that is a VS511SZ at version 38 s Displayed next is indicating the system is configured for a heater between 3 and 6 kW or indicating the system is confi...

Страница 5: ...figuration and DIP Settings Setup 1 As Manufactured 240V Pump 1 2 Speed 240V Pump 2 1 Speed 240V Blower 120V Ozone 12V Spa Light 120V A V Stereo 240V 5 5kW Heater VL700S VL701S VL702S Main Panel 120V...

Страница 6: ...th A3 and A7 are ON SSID 100 65 51 WARNING Setting DIP switches incorrectly may cause abnormal system behavior and or damage to system components Refer to Switchbank illustration on Wiring Configurati...

Страница 7: ...onnector J29 See the ratings table on the wiring diagram attached to the cover of the enclosure for the configured voltage For 240V output W2 connects to Red AC and for 120V output W2 connects to Whit...

Страница 8: ...r Jets 2 VL702S PN 54652 with Overlay PN 11790 Connects to Main Board terminal J1 only Blower Warm Heat Jets 1 Jets 2 Blower Light Mode Warm Cool Heat VL701S Serial Standard PN 53189 01 with Overlay P...

Отзывы: