background image

Page 3

54371-03_97_A

Additional Options

•  Full Feature Dolphin Remote

and Spa-only Dolphin Remote

•  IR Receiver Module

Connects to terminal J1 or J2

• MoodEFX Lighting

Connects to Spa Light terminal J20

• FiberEFX Lighting

Connects to Spa Light terminal J20

Power Requirements

•  240VAC, 60Hz, 40A, Class A GFCI-protected service (Circuit Breaker rating = 50A max.)
•  4 wires [hot, hot, neutral, ground]

System Outputs

BALBOA INSTRUMENTS, INC.

VS500Z
P/N  22972 REV D

MADE IN U.S.A

COPYRIGHT 2005

J7

J8

J44

J60

J22

U4

FUSE

K8

K5

J1A

J10

J13

J2A

EXT.

RLY

AUX. F

SEN. A

SEN. B

VAC

J1

J2

W2

W3

J12

1

2 3

2-SPD 

EXT RLY

J18

Basic System Features and Functions

Basic System Features and Functions

Setup 1 (As Manufactured)

•  240V Pump 1, 2-Speed
•  240V Pump 2, 1-Speed
• 240V 

Blower

•  120V Ozone *
•  12V Spa Light
•  120V AV (Stereo)
•  240V 5.5kW Heater **

Optional Devices

•  120V Circ Pump *

*  Ozone and Circ Pump must be same voltage.
**  Heater wattage is rated at 240V.  When running 120V to heater, output is approximately 25%.

Содержание VSP-VS510SZ-DCAH

Страница 1: ...07 11 2011 Template used 40600_P pdf 01 07 2008 Balboa Instruments System PN 54371 03 System Model VSP VS510SZ DCAH Software Version 51 EPN 3609 Base PCBA PN 54372 03 PCB VS500Z PN 22972 Rev C or D Ba...

Страница 2: ...ry System PN EPN Date Requested By Changes Made 54371 01 1801 08 09 2006 Balboa n a 54371 02 2765 04 14 2008 Balboa Software update to v43 54371 03 3609 07 11 2011 BWG Reduce poll duration from 2 minu...

Страница 3: ...d System Outputs BALBOA INSTRUMENTS INC VS500Z P N 22972 REV D MADE IN U S A COPYRIGHT 2005 J7 J8 J44 J60 J22 U4 FUSE K8 K5 J1A J10 J13 J2A EXT RLY AUX F SEN A SEN B VAC J1 J2 W2 W3 J12 1 2 3 2 SPD EX...

Страница 4: ...system For example if these three numbers are that is a VS511SZ at version 38 s Displayed next is indicating the system is configured for a heater between 3 and 6 kW or indicating the system is confi...

Страница 5: ...figuration and DIP Settings Setup 1 As Manufactured 240V Pump 1 2 Speed 240V Pump 2 1 Speed 240V Blower 120V Ozone 12V Spa Light 120V A V Stereo 240V 5 5kW Heater VL700S VL701S VL702S Main Panel 120V...

Страница 6: ...th A3 and A7 are ON SSID 100 65 51 WARNING Setting DIP switches incorrectly may cause abnormal system behavior and or damage to system components Refer to Switchbank illustration on Wiring Configurati...

Страница 7: ...onnector J29 See the ratings table on the wiring diagram attached to the cover of the enclosure for the configured voltage For 240V output W2 connects to Red AC and for 120V output W2 connects to Whit...

Страница 8: ...r Jets 2 VL702S PN 54652 with Overlay PN 11790 Connects to Main Board terminal J1 only Blower Warm Heat Jets 1 Jets 2 Blower Light Mode Warm Cool Heat VL701S Serial Standard PN 53189 01 with Overlay P...

Отзывы: