background image

COUNTERTOP GAS DECK OVEN OPERATION MANUAL

5

INSTALLATION INSTRUCTIONS

(i)     A separate shut-off valve for each oven must be 

provided. It should be as close as possible to the 
place where the gas supply line goes into the 
oven. It must be located such that it is easily 
accessible.

(j)    When stacking with another oven, two shut-off 

valves, one for each of the two ovens, must be 
provided.

After the Gas Supply has been connected, it is 
extremely important to check all the piping for 
leaks. Use a soap and water solution or a product 
expressly made for this purpose.  Do not use 
matches, candles or a flame etc. to check leaks 
since these methods are extremely dangerous

CAUTION

Flue Diverter 
(For use w/
Collection 
Hood)

Figure 1

Draft Hood 
(For use 
w/Direct  
Venting)

Figure 2

Figure 3

Flue Connection - Ventilation:
Installation Under Ventilation Hood (Standard):

If the oven is not vented directly and is installed under 
a collection hood, use the flue diverter (fig.1) supplied. 
Local inspectors and ventilation and environmental 
specialists should be consulted so that the design 
and the installation of the hood conforms to the local / 
municipal codes (See fig.3).

Direct Venting (Optional)  

Not Available For European Community Countries: 

If direct venting, it is necessary to install a draft hood 
(fig.2). The flue pipe from the draft hood must not run 
downwards at any point from the oven to the final outlet. 
It should always slant slightly upwards. For best results 
it should rise straight up.

Do not put a damper in the flue and do not 
connect a blower directly to the flue.  If the flue 
runs directly to the free air outside the building, 
use a wind deflector or a UL listed vent cap at 
the end of the flue pipe. Termination of the vent 
must be at least 2 feet above the highest part 
of the roof within 10 feet (Ref: American Gas 
Association Catalog No. Xh0474)

NOTICE

Main Burner Safety Pilot Operation:

The purpose of the safety pilot system is to lock the gas 
supply to the main burner at the combination valve, if 
for any reason the pilot burner is not lit. Oven should be 
relighted by following the steps given below. However, 
in normal service, the pilot flame stays lit indefinitely, 
day and night or weekends. This prolongs the life of the 
safety valve.

The safety pilot valve is in effect a two-stage control. 
After initial lighting, the pilot burner stays on without the 
gas cock dial being held pressed in. After 1-2 minutes, 
the valve opens fully to let the gas flow past the safety 
pilot valve into the burner system.

Содержание GP-54

Страница 1: ...BUILT BY CRAFTSMEN TESTED BY TIME SERIES GP OPERATION MANUAL HEARTHBAKE SERIES COUNTERTOP GAS OVENS...

Страница 2: ...nent location in the kitchen area This information shall be obtained from the local gas supplier NOTICE BAKERS PRIDE OVEN COMPANY LLC 1307 N Watters Rd Suite 180 Allen TX 75013 Phone 800 527 2100 Fax...

Страница 3: ...t 8 Oven Interior 8 Baking Chamber 8 Baking Decks 9 Burner Compartment 9 Troubleshooting Chart 9 EXPLODED VIEWS PARTS LISTS GP 51 Parts List w Exploded Views 10 GP 61 Parts List w Exploded Views 13 WA...

Страница 4: ...on Minimum Clearance from Left Side 2 51mm 2 51mm Minimum Clearance from Right Side 1 25mm 0 Minimum Clearance from Rear 5 127mm 2 51mm Set Up Your oven is packed in a carton and strapped to a skid Re...

Страница 5: ...the Standard for Connectors for Movable Gas Appliances ANSI Z21 69 in the USA CAN CGA 6 16 in Canada and a quick disconnect device that complies with the latest edition of the Standard for Quick Disco...

Страница 6: ...tion in compliance with EN 60335 1 and or local codes c The ovens should not be installed on the same line with space heaters boilers or other gas equipment with high intermittent demand d Use a pipe...

Страница 7: ...ct Venting Optional Not Available For European Community Countries If direct venting it is necessary to install a draft hood fig 2 The flue pipe from the draft hood must not run downwards at any point...

Страница 8: ...That indicates a good mixture of gas and air When using LP gas the flame will have a blue yellow appearance Should the Burner fail to light check to see if there is a problem with the gas supply If t...

Страница 9: ...pan When you determine the combination of method ingredients and temperature that gives the right bake for your crust sauce and cheese combination and your customer s taste mark and keep it Deck baki...

Страница 10: ...ent solutions and cleaners that meet the national and or local codes Baking Chamber Clean the ceiling and the walls of the baking chamber with a mild soap and water solution Do not use oven cleaners c...

Страница 11: ...ot light Gas valve feeding oven may be in the closed position Turn gas valve on Relight pilot Thermopile may not be positioned in pilot flame Ensure that the tip of thermopile is in pilot flame Thermo...

Страница 12: ...COUNTERTOP GAS DECK OVEN OPERATION MANUAL 10 EXPLODED VIEWS PARTS LISTS Figure A GP 51 Exterior Deck Burner Compartment Rod Door Interior Trim...

Страница 13: ...ASTERS W LOCKS Burner Compartment ITEM PART DESCRIPTION 35 A5258X UPPER BREATHER PAN 36 A5321K FLUE DEFLECTOR SET LEFT RIGHT 37 A5237X SLIDE OUT FLAME DIVERTER 38 A5341K INSULATION PAN SET TOP BOTTOM...

Страница 14: ...LANK SPUD 2 FOR 2 INSPIRATOR 69 M1296X THERMOCOUPLE T 46 USED W BGOR Figure B GP 51 Burner Figure C GP 51 Plumbing Control ITEM PART DESCRIPTION 70 M1392X CONTROL ASSY TO UNION N G BGOR 71 M1393X CONT...

Страница 15: ...COUNTERTOP GAS DECK OVEN OPERATION MANUAL 13 EXPLODED VIEWS PARTS LISTS Figure A2 GP 61 Exterior Deck Burner Compartment Rod Door Interior Trim...

Страница 16: ...VERTER 38 A5259X INSULATION PAN SET TOP BOTTOM 39 A5251X COMBUSTION CHAMBER FRONT CENTER O S 40 A5252X BURNER ACCESS COVER O S 41 A5301K COMBUSTION CHAMBER FRONT CENTER 42 A5302K BURNER ACCESS COVER 4...

Страница 17: ...GP 61 Burner Figure C2 GP 61 Plumbing Control ITEM PART DESCRIPTION 76 M1392X CONTROL ASSY TO UNION N G BGOR 77 M1393X CONTROL ASSY TO UNION L P BGOR 78 M1290X CONTROL ASSY TO UNION N G BMVR O S 79 M1...

Страница 18: ...diants Stones and Valves are covered for a period of SIX MONTHS All Ceramic Baking Decks are covered for a period of THREE MONTHS The installation of these replacement decks is the responsibility of t...

Страница 19: ...ANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment For Warranty Service and or Parts this information is required Model Number Serial Number...

Страница 20: ...18 NOTES...

Страница 21: ...19 NOTES...

Страница 22: ...offering a wealth of refrigeration and cooking expertise Products include walk in coolers and freezers hot and cold display cabinets cases and storage systems commercial ovens rotisseries and cooking...