INSTALLATION INSTRUCTIONS
(i) A separate shut-off valve for each oven must be
provided. It should be as close as possible to the
place where the gas supply line goes into the
oven. It must be located such that it is easily
accessible.
(j) When stacking with another oven, two shut-off
valves, one for each of the two ovens, must be
provided.
After the Gas Supply has been connected, it is
extremely important to check all the piping for
leaks. Use a soap and water solution or a product
expressly made for this purpose. Do not use
matches, candles or a flame etc. to check leaks
since these methods are extremely dangerous
CAUTION
Flue Diverter
(For use w/
Collection
Hood)
Figure 1
Draft Hood
(For use
w/Direct
Venting)
Figure 2
Figure 3
Flue Connection - Ventilation:
Installation Under Ventilation Hood (Standard):
If the oven is not vented directly and is installed under
a collection hood, use the flue diverter (fig.1) supplied.
Local inspectors and ventilation and environmental
specialists should be consulted so that the design
and the installation of the hood conforms to the local /
municipal codes (See fig.3).
Direct Venting (Optional)
Not Available For European Community Countries:
If direct venting, it is necessary to install a draft hood
(fig.2). The flue pipe from the draft hood must not run
downwards at any point from the oven to the final outlet.
It should always slant slightly upwards. For best results
it should rise straight up.
Do not put a damper in the flue and do not
connect a blower directly to the flue. If the flue
runs directly to the free air outside the building,
use a wind deflector or a UL listed vent cap at
the end of the flue pipe. Termination of the vent
must be at least 2 feet above the highest part
of the roof within 10 feet (Ref: American Gas
Association Catalog No. Xh0474)
NOTICE
Main Burner Safety Pilot Operation:
The purpose of the safety pilot system is to lock the gas
supply to the main burner at the combination valve, if
for any reason the pilot burner is not lit. Oven should be
relighted by following the steps given below. However,
in normal service, the pilot flame stays lit indefinitely,
day and night or weekends. This prolongs the life of the
safety valve.
The safety pilot valve is in effect a two-stage control.
After initial lighting, the pilot burner stays on without the
gas cock dial being held pressed in. After 1-2 minutes,
the valve opens fully to let the gas flow past the safety
pilot valve into the burner system.