background image

XX & CH CHARBROILER OPERATION MANUAL

2

INSTALLATION INSTRUCTIONS

Gas Connection:

The gas pressure regulator supplied must be installed 
at the gas inlet of each broiler. Each regulator is 
adjusted to yield a manifold pressure of 5 in. water 
column for natural gas or 10 in. water column for 
propane gas. No pressure regulator is required for 
propane gas in Canada.

Recommended minimum gas supply lines are listed below

All XX Models

CH-4 thru CH-8

CH-10 thru CH-16

3/4”

1”

1 1/2”

General:

The instructions in this manual apply to all XX series and 
CH series Broilers.

The XX series may include the following options:

Ceramic briquettes designated by a GS Suffix on the 
model number.

Installation:

(a)  In USA, INSTALLATION of this broiler must 

conform with the latest edition of the National Fuel 
Gas Code, ANSI Z223.1 and/or local codes.

(b)  In CANADA, INSTALLATION must conform with 

the latest edition of the National Gas Installation 
Code, CAN/CGA-B149.1 or the Propane 
Installation Code, CAN/CGA-B149.2, as applicable 
and/or local codes.

(c)  In MASSACHUSETTS, All gas products must be 

installed by a “Massachusetts” licensed plumber 
or gas fitter. Ventilation hoods must be installed in 
accordance with NFPA-96, current edition, with 
interlocks as described in that standard.

Acceptable Clearances:

Due to intense heat generated by radiation, these 
broilers should be installed in non-combustible locations 
only including above the grate level.

Minimum Clearance From Non-Combustible 
Construction.

Series

Right

Left

Back

XX

0”

0”

0”

CH

0”

0”

0”

For units using propane gas, supply lines less than 
1/2” inside diameter should not be used, even for a 
small unit.

On the XX and CH series, the gas connection is located 
on the right rear of the unit.

Be sure to cap whichever side is not connected.

CAUTION

When making gas pipe connections, pipe joint 
compound resistant to the action of liquefied petroleum 
gases should be used.

The broiler and its individual shutoff valve must be 
disconnected from the gas supply piping system during 
any pressure testing of that system at test pressures in 
excess of 1/2 psig (3.45 kPa).

The broiler must be isolated from the gas supply piping 
system by closing its individual manual shutoff valve 
during any pressure testing of the gas supply piping 
system at test pressures equal to or less than 1/2 psig 
(3.45 kPa).

Burners:

Check to see that AIR MIXER CAPS on the front of 
all burners are tightened and adjusted, allowing half 
the opening to show. Install the burners and deflector 
shields first following the steps below.

(a)  Install all burners with deflector shield assemblies 

attached.

(B) Place the front of the burner into the valve 

assembly by fitting the center hole of the mixer 
cap over the brass orifice.

(c)  Drop the rear end of the burner over the burner 

support pin on the back of the unit.

A shut-off valve in a readily accessible location 
must be mounted on the gas supply line before 
the unit.

NOTICE

Содержание Dante CH-14

Страница 1: ...BUILT BY CRAFTSMEN TESTED BY TIME SERIES XX CH OPERATION MANUAL DANTE SERIES GAS CHARBROILERS ...

Страница 2: ... installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING Instructions must be posted in a prominent location All safety precautions must be taken in the event the user smells gas Safety information can be obtained from your local ...

Страница 3: ...TION GUIDE 7 TROUBLESHOOTING GUIDE 7 BURNER FLAME ADJUSTMENT 7 PILOT FLAME ADJUSTMENT 7 LACK OF HEAT 7 ONE BURNER FAILS TO LIGHT 8 TROUBLESHOOTING CHART 8 VALVE ASSEMBLY VIEWS 9 PARTS LISTS EXPLODED VIEWS 10 MODELS XX 4 6 8 10 12 PARTS LISTS EXPLODED VIEWS 10 MODELS CH 6 8 10 12 14 PARTS LIST EXPLODED VIEW 13 WARRANTY 15 SAFETY PRECAUTIONS This symbol warns of imminent hazard which will result in ...

Страница 4: ...d in non combustible locations only including above the grate level Minimum Clearance From Non Combustible Construction Series Right Left Back XX 0 0 0 CH 0 0 0 For units using propane gas supply lines less than 1 2 inside diameter should not be used even for a small unit On the XX and CH series the gas connection is located on the right rear of the unit Be sure to cap whichever side is not connec...

Страница 5: ...ler has a standing pilot burner that must be lit before the burners can be lit To light the pilot burners a Turn all broiler valves to the off position b Remove each top grate and radiant c Open main gas SHUT OFF valve supplied by customer d Allow air to bleed from the gas line through the pilot burners e Light the pilot burners using a lit taper f Turn the burner control valves ON to light the bu...

Страница 6: ...ce that complies with the latest edition of the Standard for Quick Disconnect Devices for use with gas fuel ANSI Z21 41 in USA CAN 1 6 7 in Canada and adequate means must be provided to limit the movement of the appliance without depending upon the connector and any quick disconnect device or its associated piping to limit the appliance movement c The restraint should be attached to the legs on wh...

Страница 7: ...before broiling will compensate for the shrinkage Broil a hamburger as you would broil a steak 1 Be sure that the charbroiler has had adequate pre heating time so that the hamburger does not stick to the broiler grate 2 Place the hamburger on the grate and allow it to cook until release is attained 3 Once the hamburger releases from the grate turn it over and allow it to cook for 1 minute then tur...

Страница 8: ...ce flare up trimming excess fat for a longer broil time without burning e Keep the unit clean Food caught between the grates will not allow hot air to rise around the product This will result in uneven heating and increase cook time Maintenance a Service Shut off the main gas supply before attempting any maintenance on the unit If required contact your Dealer the Factory or a local Service Company...

Страница 9: ... air into the burner until the flame turns blue Tighten the screw Pilot Flame Adjustment The pilot flame can be adjusted by turning the appropriate adjusting screw using a screwdriver or a 3 16 wrench see fig 2 counter clockwise to increase clockwise to decrease and close The pliot flame should be about 1 2 inch long Lack Of Heat Check to see if the pilot flames are on If they are on but the burne...

Страница 10: ...ough to clear the burner orifice fig 3 or 4 Using a thin wire or pin check to see that the orifice is clear taking care not to enlarge the hole Replace the burner radiant and grate and attempt to light it again If the burner will not light the burner valve could be defective Contact your dealer the factory or a local service company For additional information contact Bakers Pride Oven Co Inc 914 5...

Страница 11: ...XX CH CHARBROILER OPERATION MANUAL 9 VALVE ASSEMBLY VIEWS Valve Assembly Views Figure 2 Air Mixer Cap And Pilot Burners Figure 3 Side View CH Series A Cap Hold Down Screw Figure 3 Side View XX Series ...

Страница 12: ...er Only C I 24 w Mixer Cap XX O S 18 R3022X Air Mixer Cap w Screw C I Burner only 19 H1008X Grease Guard Only C I Burner 20 T1007A Radiant Cast Iron 23 Optional Shown 21 T1155T Radiant S S 23 Standard 22 M1009X Pressure Regulator 3 4 10 WC 23 M1008X Pressure Regulator 3 4 5 WC 24 R3043X Orifice Hood 47 Nat XX 25 R3044X Orifice Hood 55 LP XX 26 R3023X Orifice Hood Blank 27 T5041T Grate Lifter Cast ...

Страница 13: ...XX CH CHARBROILER OPERATION MANUAL 11 PARTS LISTS AND EXPLODED VIEWS EXPLODED VIEW XX 4 6 8 10 12 Exterior Grates Note When ordering ALWAYS specify Part Model Serial Voltage Phase and Gas Type ...

Страница 14: ...EXPLODED VIEWS Item Part No Description 11 G1081X Splash Guard S S XX 4 Optional G1082X Splash Guard S S XX 6 Optional G1083X Splash Guard S S XX 8 Optional G1084X Splash Guard S S XX 10 Optional G1237U Splash Guard S S XX 12 Optional 12 T3033T Grease Pan XX 4 12 20 3 8 1 used T3034T Grease Pan XX 6 XX 10 30 7 8 1 used T3035T Grease Pan XX 8 19 5 8 2 used or XX 12 1 used T3036T Grease Pan XX 10 19...

Страница 15: ...XX CH CHARBROILER OPERATION MANUAL 13 PARTS LISTS AND EXPLODED VIEWS EXPLODED VIEW CH 6 8 10 12 14 Note When ordering ALWAYS specify Part Model Serial Voltage Phase and Gas Type ...

Страница 16: ... 3 CH 16 44 T3124X Grease Pan set 3 CH 18 45 T3125X Grease Pan set 4 CH 20 46 T3126X Grease Pan set 4 CH 22 47 T3078V S S Heat Shield w Handle CH 4 48 T3079V S S Heat Shield w Handle CH 6 49 T3080V S S Heat Shield w Handle CH 8 50 T3081X S S Heat Shield w Handle set 2 CH 10 51 T3082X S S Heat Shield w Handle set 2 CH 12 52 T3083X S S Heat Shield w Handle set 3 CH 14 53 T3084X S S Heat Shield w Han...

Страница 17: ...iants Stones and Valves are covered for a period of SIX MONTHS All Ceramic Baking Decks are covered for a period of THREE MONTHS The installation of these replacement decks is the responsibility of the purchaser The extended Cyclone door warranty years 3 through 5 is a parts only warranty and does not include labor travel mileage or any other charges EXCLUSIONS Negligence or acts of God Failures c...

Страница 18: ...t offering a wealth of refrigeration and cooking expertise Products include walk in coolers and freezers hot and cold display cabinets cases and storage systems commercial ovens rotisseries and cooking equipment and rotary vane pumps Ask your sales representative about how the power of all Standex brands can work for you www standex com segments food service Food Service Equipment Group ...

Отзывы: