SAFETY INSTRUCTIONS 

Baker  and/or  Ruskinn  do  not  take  any  responsibility  for  damages  caused  by  using  the 
equipment for other purposes than described in this user manual. 

 

The mains appliance coupler and plug are the AC  mains supply isolation  device and must be 
easily accessible when installed. 

 

In case of emergency disconnect the InvivO

2

 from the AC Mains Outlet. 

 

Ensure that the  connecting cable is not  squeezed or bent when the unit is being installed  or 
moved. 

 

All installation work and  adjustments to the unit  must  be carried out  by  qualified  personnel. 
Work  performed  by  persons  with  insufficient  technical  knowledge  may  adversely  affect  the 
performance of the unit or cause physical injury or damage to the equipment. 

 

All  servicing  and  repairs  must  be  carried  out  by  a  qualified  customer  service  engineer.  Only 
genuine spare parts must be used. 

 

In case of damage to the InvivO

2

 disconnect the workstation from the mains outlet and contact 

your local distributor. 

 

All covers and lids must only to be removed by a qualified service engineer. 

 

Nothing should be placed on the top of the workstation. 

 

A power cord supplied with the workstation and should be used to connect to the mains outlet. 
If a replacement is required it must be adequately rated for the application. 

 

All cables and pipes should be routed to ensure that they do not pose a trip hazard. 

 

Mains supply Voltage fluctuation must not exceed ±10% of the nominal Voltage. 

 

Gas regulators must be used for each gas supply. A 2 stage regulator is recommended with a 
maximum supply pressure of 4 Bar. Over pressure could damage the workstation. 

 

Only the gases specified in this user manual may be used. 

 

All gas bottles must be adequately secured before connection to the workstation. 

 

The maximum power rating of the internal sockets must not be exceeded. 

 

The end user is responsible for all materials and equipment places inside the workstation. 

 

Before connecting any equipment to the internal mains sockets ensure that the equipment has 
or is connected to a  protective earth. If in doubt please contact the equipment manufacturer.  

 

The workstation must not be operated at an ambient temperature over 30°C. 

 

The cooling fan covers and cooling vents must not be covered or blocked. 

 

The weight limit for the workstation internal floor is 30kg and must be evenly distributed. 

 

The weight limit for the interlock tray is 5kg and must be evenly distributed. 

 

There should be no naked flames close to the workstation. 

 

The use of radioactive materials if strictly prohibited. 

 

CAUTION: Asphyxiation Risk 

The  InvivO

2

 uses Nitrogen (N

2

) and Carbon  Dioxide (CO

2

) as  part of normal use with the 

volume released externally is inconsequential. In the event of a leak or malfunction this 
gas release may become excessive. DO NOT OPERATE this unit in a SMALL ENCLOSURE 
such as a small room or walk-in closet. An accidental release of Nitrogen or Carbon Dioxide 
could create an asphyxiating atmosphere in a small space. 

If  the  equipment  is  not  use  in  a  manor  specified  by  the  manufacture,  the  protection 
provided by the equipment may be impaired. 

Failure to adhere to these safety instructions could cause serious injury and will invalidate 
the workstation warranty. Ruskinn technology limited accepts no responsibility for any 
accident, injury or loss caused by unsafe operation of the workstation. 

 

Содержание InvivO2 400

Страница 1: ...Affix Serial Number Sticker Here UserManual UM 037 InvivO2 Physiological Oxygen Workstations InvivO2 400 InvivO2 500...

Страница 2: ...LING OF THE INVIVO2 WORKSTATION 6 ENVIRONMENTAL OPERATING CONDITIONS 6 SERVICE REQUIREMENTS 7 ELECTRICAL SUPPLY REQUIREMENTS 7 GAS SUPPLY REQUIREMENTS 8 INVIVO2 OVERVIEW 9 FRONT VIEW 9 FRONT INTERIOR...

Страница 3: ...TION 40 HELP SETTINGS 41 WARNINGS 42 USB TREND LOG 47 CLEANING AND SERVICE REQUIREMENTS 48 SERVICE AND CLEANING OVERVIEW 48 CLEANING PROCEDURE DURING AND AFTER EACH USE 49 CLEANING PROCEDURE DEEP CLEA...

Страница 4: ...zee Sleeve before vacuum 20 Figure 16 Ezee Sleeve after vacuum 20 Figure 17 Glove port cap 21 Figure 18 Glove port cap stowage and locator 21 Figure 19 Glove port cap storage location inside workstati...

Страница 5: ...uous Cycle Off 38 Screen 13 Hypoxic Cycle Temperature and Humidity Settings 39 Screen 14 Oxygen Sensor Calibration 40 Screen 15 Help Settings Menu 41 Screen 16 Temperature Alarm Screen 42 Screen 17 Wa...

Страница 6: ...on Dioxide CO2 and Compressed Air O2 or 25 Oxygen in Nitrogen to achieve the desired atmosphere The user can select the Oxygen concentration from 0 1 to 20 9 and Carbon Dioxide concentrations from 0 1...

Страница 7: ...r Over pressure could damage the workstation Only the gases specified in this user manual may be used All gas bottles must be adequately secured before connection to the workstation The maximum power...

Страница 8: ...ls on standards tested refer to the DoC Certificate WEEE This equipment must be disposed of in accordance with the Waste from Electrical and Electronic Equipment WEEE Directive This product must not b...

Страница 9: ...ference in which case the user will be required to correct the interference at his own expense Precautions The InvivO2 has been tested and approved to EN61010 1 61326 1 and 61326 2 6 This means that t...

Страница 10: ...r to this manual in all cases where this symbol appears in order to find out the nature of the Potential Hazard and actions to be taken in order to avoid the Hazard Warning this equipment contains hig...

Страница 11: ...elocated by a qualified engineer To arrange installation or relocation please contact your local distributor The mains appliance coupler and plug are the AC mains supply isolation device and must be e...

Страница 12: ...voltage and frequency for InvivO2 workstations are Voltage Range Frequency Nominal Power Rated Current Rated Power 220 to 240 Vac 50 60Hz 360W 8 1A 1830W 110 to 120 Vac 50 60Hz 360W 14 3A 1600W 100 V...

Страница 13: ...aximum of 25 Oxygen in Nitrogen Industrial or medical Air For oxygen levels between 17 and 23 42 to 49psi 3 to 3 5 bar Table 5 Additional gases for specific operating modes Figure 2 Gas Connection Gra...

Страница 14: ...ure 3 and Figure 4 respectively Figure 3 Standard InvivO2 Workstation with SPES Option Figure 4 Large InvivO2 Workstation 1 Ezeeyin Glove Ports 2 Single Plate Entry System SPES Optional Accessory 3 Re...

Страница 15: ...gure 6 Left Side Internal View 1 Internal Light 2 Temperature and Humidity Sensor Housing 3 Internal interlock door 4 Internal sockets 5 Humidity Outlet Optional 6 Condensate plate 7 Universal Port Op...

Страница 16: ...View Figure 7 Left Side End Panel with Ultrasonic Humidity Option 1 Lid Service access only 2 Humidity water tank optional 3 Side Panel Service access only 4 Cooling vent Do not obstruct 5 Universal...

Страница 17: ...Page 12 of 59 Right Side View Figure 8 Right Side End Panel 1 Cooling vent Do not obstruct 2 Side Panel Service access only 1 2...

Страница 18: ...ly Connections Figure 10 Gas and Electrical Connections 1 Safety Label 2 Rear panel Service access only 3 Ethernet Port For use with Remote Monitoring Option Only See Service Requirements section for...

Страница 19: ...nterlock Overview The interlock consists of 4 main components Interlock outer door Interlock inner door Interlock chamber Interlock floor tray The interlock is accessed by opening either the outer or...

Страница 20: ...d closed as often as required to transfer material providing the outer door has not been opened Transferring material into the workstation chamber via the interlock To transfer material into the works...

Страница 21: ...interlock purge cycle has completed indicated by the touchscreen and the inner door push button illumination press the inner door button Slide the interlock inner door backwards to open the interlock...

Страница 22: ...al from the workstation chamber into the interlock chamber Close the interlock inner door by sliding the interlock inner door forwards Exit the workstation chamber via the Ezeeyin glove ports Open the...

Страница 23: ...is provided via the Ezeeyin glove ports and Ezee Sleeve The Ezee Sleeve consists of a gloveless gas tight sleeve and a cuff The Ezee Sleeve attaches to the glove port via two O rings Note The worksta...

Страница 24: ...zee Sleeve before inserting the hand and arm as shown in Figure 12 Figure 12 Compressed Ezee Sleeve for Entry Hold the desired Ezee Sleeve cuff with the opposite hand Support the Ezee Cuff push the ha...

Страница 25: ...ion should be continued until the maximum amount of external atmosphere has been removed from the Ezee Sleeve and the Ezee Sleeve exerts some pressure on the arm hand Figure 15 Ezee Sleeve before vacu...

Страница 26: ...Cap can require a reasonable amount of force This can be made easier by pushing the uppermost part of the Handle to first break the vacuum at the upper edge of the Cap seal Figure 17 Glove port cap T...

Страница 27: ...Page 22 of 59 Figure 19 Glove port cap storage location inside workstation Repeat the procedure for the other hand if both hands are entering the workstation chamber...

Страница 28: ...the Glove Port replace the cap using the location posts and graphic to orient the Cap correctly on the Glove Port Note Care should be taken to ensure that the Ezee Sleeve material does not become caug...

Страница 29: ...nto the workstation atmosphere The workstation allows the humidity to rise to a user defined maximum at which point it will start to strip the excess humidity away at a control accuracy of 6 One sache...

Страница 30: ...from the tank is then passed through a filter to ensure that there is no contamination of the water supply to ultrasonic nebuliser Water Tank The water tank is included as part of the ultrasonic humi...

Страница 31: ...crews holding the water tank in place Figure 25 Water Tank Thumb Screw Once these are removed the water tank can be lowered in the end panel to expose the top of the tank then tilting the top forward...

Страница 32: ...Page 27 of 59 Figure 27 Water Tank tilted forward partially removed Figure 28 Water Tank top tube removal...

Страница 33: ...Page 28 of 59 Figure 29 Water Tank electrical connector Figure 30 Water Tank bottom lifted out...

Страница 34: ...s below the tube connector to avoid spillage as the tube is removed Figure 31 Water Tank bottom tube disconnection Re installation is carried out reversing the removal procedure Once the humidity syst...

Страница 35: ...below the dew point to allow for the humidity to condense on the plate Figure 32 Condensate Plate As this forms droplets these are then collected into a small reservoir in the end panel that will the...

Страница 36: ...EENS Main screen When the unit is first powered on a Ruskinn Logo screen will appear and will be replaced by Screen 3 Screen 3 Main Menu From this menu you will be able to access all of the features o...

Страница 37: ...nts High Alarm Levels Low Alarm Levels Table 6 Settings screen column functions Rows 2 3 and 4 can be changed by the user by pressing on the value and a pop up will appear for the new setting to be se...

Страница 38: ...ity option fitted then the humidity set point is can be adjusted in increments of 5 using the arrows The software will then allow the humidity to rise to this value and limit the maximum internal humi...

Страница 39: ...use to monitor the current workstation conditions and gain access to all of the in use functions Screen 7 Environment Control Overview Pressing the home icon on the bottom right will bring up Screen 8...

Страница 40: ...own at the top of the box The red horizontal lines show the current Alarm levels from the settings screen to easily see if there have been any deviations outside of the required operating parameters P...

Страница 41: ...e left turns the light on off and the bar will adjust the brightness of the lights in the main work area This bar can either be slid into position or tapping on the setting required Icon 3 Internal Li...

Страница 42: ...een the steps that is not able to be set as it is dependent on the difference between the set points within the gas control software Pressing on any of the values will bring up a dialogue box to enter...

Страница 43: ...continuous cycle you are able to select up to 3 different set points with a time to remain at each and if you only want 2 set points to can set step 3 to 0 minutes and copy the set points from step 2...

Страница 44: ...perature and Humidity Settings Within the Hypoxic Mixing cycles the workstation will maintain the temperature and humidity settings These settings are accessed from the button on Screen 11 or Screen 1...

Страница 45: ...ation point and the ambient atmosphere for the high operation point The Atmospheric Oxygen level is set to 20 9 as default but this can be changed if required Once this setting is entered to the corre...

Страница 46: ...nterlock door when the button is pressed for 3 seconds Icon 2 Internal Lights This will open a separate pop up shown in Icon 3 The icon on the left turns the light on off and the bar will adjust the b...

Страница 47: ...ing the initial turn in or if the set point has been changed by more than 0 2 C The alarm can be dismissed by pressing the return arrow at the bottom right of the screen If the workstation still has n...

Страница 48: ...This can be dismissed by pressing the back arrow at the bottom right but it will appear again if the water level is still too low after 20 minutes If the water tank is re filled then the alarm will au...

Страница 49: ...ved for longer than 5 minutes as a reminder to replace it after the log files have been copied to a computer for analysis This alarm can be dismissed by pressing the back arrow at the bottom right of...

Страница 50: ...workstation to avoid excessive gas usage as it indicates an issue with the gas tightness of the workstation Screen 19 Gas Mix Time Limit Warning Screen The alarm can be dismissed by pressing the back...

Страница 51: ...e refer to the section for common problems and solutions Screen 20 Input Gas Pressure Alarm Alarm Purpose Alarm Buzzer Sound Temperature Alarm 1 second Pulse On Off Input Gas Pressure Alarm Continuous...

Страница 52: ...t point CH9 Chamber Temp Actual Chamber Temperature Measurement in C CH10 Water Tank Level For workstations with Ultrasonic Humidity this is the water level remaining in the Water Tank CH11 Interlock...

Страница 53: ...waste port bag Weekly End User Fill humidifier tanks Weekly End User Calibrate oxygen sensors Monthly End User Deep clean workstation 3 6 months End User Replace detox sachets Annually End User Qualif...

Страница 54: ...e permitted The use of UV light is prohibited in the workstation as it will cause permanent damage The use of UV Light within the Workstation will invalidate the warranty Cleaning procedure during and...

Страница 55: ...ble alarm in all screens other than the main menu The following screen will appear to ensure that the glove port pneumatic connector is disconnected before the screen is removed Figure 34 Front Screen...

Страница 56: ...the workstation o Interlock side walls o Interlock ceiling o Interlock floor trays o Interlock outer door For all workstation components wipe with a paper towel soaked in an appropriate cleaning agent...

Страница 57: ...ation chamber Close the outer interlock doors Plug the workstation back in at the mains Switch the workstation on Go into the setting menu reinstall the front screen activate the seal and connect the...

Страница 58: ...leeves Service Instructions Follow the Deep Cleaning Preparation stage Unscrew the 2 thumb screws retaining the ceiling panel in the workstation Figure 35 Ceiling Panel Thumb Screws Pull down the ceil...

Страница 59: ...humbscrews Remove the used sleeves from the front screen and dispose of them Figure 38 Gloveport Sleeves Follow the Deep Cleaning Cleaning instructions using the appropriate cleaning material in the s...

Страница 60: ...station to identify low input gas pressures The gas input pressure is set to low o Check the gas supply bottle pressure is set to the recommended levels defined in the Gas Supply Requirements section...

Страница 61: ...n If the problem persists after the above have been carried out then please contact your distributor to assist in identifying the issue or to arrange a service engineer visit Internal Equipment not po...

Страница 62: ...ARTICULAR PURPOSE THE IMPLIED WARRANTY OF MERCHANTABILITY OR ANY IMPLIED WARRANTY ARISING OUT OF A COURSE OF DEALING OR OF PERFORMANCE CUSTOM OR USAGE OF TRADE Ruskinn Technology Limited DOES NOT WARR...

Страница 63: ...household waste site Instead it should be taken to the appropriate collection point for the recycling of electrical and electronic equipment Alternatively please contact your local distributor for dis...

Страница 64: ...rt ruskinn com General enquiries ruskinnoffice ruskinn com Website www bakerruskinn com YouTube channel http www youtube com ruskinntechnology Ruskinn Technology Limited is a registered company in Uni...

Отзывы: