background image

Industry-Leading Technologies Provide Superior  
Protection and Maximum Efficiency

The aerodynamic ChemGARD® design employs fixed air slots 
at maximum safety configuration to alleviate the need for  
cumbersome operator adjustments.

• 

ChemGARD® construction materials are flame resistant.

• 

Top-suspended, 12" wide safety plate glass sash panels 
are easily removed for cleaning.

• 

Unique  internal  baffle  location  minimizes  retained  
vapors in work area.

• 

ChemGARD® fits through standard doorways and, once 
installed, requires only a 2" aisle overhang.

• 

Radius bottom airfoil minimizes turbulence.

ChemGARD® General Purpose Models

• 

Stainless  steel  bolted,  16-gauge,  Type  304  stainless 
steel liner provides long-term durability, easy cleaning and resistance to corrosion (can be epoxy coated as 
an option).

• 

A molded, dished epoxy resin work surface confines spills.

• 

Recessed work surface encourages proper placement of potentially hazardous chemicals.

ChemGARD® RI Radioisotope Models

• 

Formed radii, precision-engineered, 16-gauge, Type 304 stainless steel, coved corners, water-tight   welded 
and polished seams.

• 

Coved corner stainless steel work surface, ¾" deep, continuously welded to interior.

• 

Reinforced work surface accommodates lead shielding, supports maximum 200 lbs/sq.ft., to  work surface 
weight of 1,000 lbs. 

• 

Stainless steel provides long-term durability, easy cleaning and resistance to corrosion.        

PAGE 

2

Learn More!

Scan  the  code  to  the  right  or  visit 
http://hubs.ly/y03_8s0  to  learn  how  
continuous-flow  bypass  technology  
improves  fume  hood  safety  and  
performance.

Содержание ChemGARD FH4

Страница 1: ...Underwriter Laboratories Listed C h e m G A R D ...

Страница 2: ...ces roll effect fluctuations in the airflow that may cause harm to the worker Offers a streamlined unobstructed work area Minimizes lingering concentrations above and behind the viewscreen Reduces contaminant concentrations near the edge of the sash window reducing potential exposure hazard to personnel ChemGARD FumeHoods ...

Страница 3: ...alarm monitor configurations 4 Angled entrance airfoil and radius work surface for undisturbed airflow into work area 5 Color coded service fixtures with convenient remote control valves positioned outside the air stream 6 Counterbalanced vertical sash for smooth single handed operation 7 Recessed work surface confines spills 8 All stainless steel construction for durability and easy cleaning 9 Op...

Страница 4: ...el liner provides long term durability easy cleaning and resistance to corrosion can be epoxy coated as an option A molded dished epoxy resin work surface confines spills Recessed work surface encourages proper placement of potentially hazardous chemicals ChemGARD RI Radioisotope Models Formed radii precision engineered 16 gauge Type 304 stainless steel coved corners water tight welded and polishe...

Страница 5: ...ed controls include flush membrane switches that are easy to operate and easy to clean Independent light and duplex electrical outlet switches are included on the main control panel Remote alarm contacts allow integration with existing laboratory monitoring systems Horizontal VerticalSashOffersAdvantages The ChemGARD incorporates a combination horizontal vertical sash designed for energy savings o...

Страница 6: ...atures include Acid Storage Base Cabinet The acid storage base cabinet has an acid resistant polypropylene drip tray shelf liner and optional vent assembly with flexible polypropylene hose designed to T into the fume hood exhaust plenum Reinforced shelf adjustable on 1 centers Dual panel doors 1 thick secured with 3 wide continuous hinge 3 point latch 18 gauge cold rolled steel bottom pan recessed...

Страница 7: ...ll andtwofrontremovablerearpanelsprovideaccesstothe10 deep chase at the rear to allow for installation of the optional vent package Access panels are located at each end of the chase An optional vent package offers from 10 to 15 air changes per hour depending on cabinet size the vent assembly with flexible hose is designed to T into the fume hood A reinforcedType 304 stainless steel shelf is adjus...

Страница 8: ...x 908 mm 1 524 x 737 x 908 mm 1 829 x 737 x 908 mm Interior Dimensions W x D x H 38 5 8 x 18 x 24 7 16 50 5 8 x 18 x 24 7 16 62 5 8 x 18 x 24 7 16 981 x 470 x 621 mm 1 286 x 470 x 621 mm 1 591 x 470 x 621 mm Useable Work Surface W x D 38 5 8 x 18 50 5 8 x 18 62 5 8 x 18 981 x 470 mm 1 286 x 470 mm 1 591 x 470 mm ExhaustandStaticPressureRequirements CombinationHorizontal VerticalSash Exhaust Airflo...

Страница 9: ......

Страница 10: ...the invoice date The exclusive remedy for any breach or violation of this warranty is as follows The Baker Company Inc will F O B Sanford Maine furnish without charge repairs to or replacement of the parts or equipment that proved defective in material or workmanship No claim may be made for any incidental or consequential damages THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESSE...

Отзывы: