Bugbox M User Manual 

 

Service requirements 

To  maintain  the  best  performance  from  the  Bugbox  M  workstation,  it  must  be  serviced  at  regular 
intervals. Figure 29 lists the servicing requirements, intervals and persons capable of performing the 
service; 

Figure 29: Bugbox M servicing requirements 

Action 

Frequency 

By 

Clean workstation 

After each use 

End User 

Fill humidifier tank 

Weekly 

End User 

Deep clean workstation 

3-6 months depending on usage 

End User 

Replace detox sachets 

Annually 

End User 

Replace catalyst sachet (if used)  Annually 

End User 

Annual service 

Annually 

Qualified service engineer 

Biennial service 

Biennially (2 yearly) 

Qualified service engineer 

To arrange an annual or biennial service, contact your local distributor. Note that the biennial service 
includes an annual service. Note The annual service includes the replacement of the detox and the 
catalyst sachet. 

Service contracts are available for all Ruskinn Technology Limited workstations. Please contact your 
local distributor for more information. 

 

Spare parts and accessories 

A range of spare parts and accessories are available for the Bugbox M workstation. Note: Only Ruskinn 
Technology Limited spare parts should be used. The use of unapproved spare parts will invalidate the 
warranty of your workstation and may cause damage to your workstation. 

 

Overview 

To order spare parts and accessories, please contact your local distributor for the latest pricing and 
availability. 

 

Spare parts and cleaning agents 

Figure 30 lists the spare parts and cleaning agents available for the Bugbox M workstation. To order 
spare parts, please contact your local distributor for the latest pricing and availability. All items are 
sold individually except where stated. 

Содержание Bugbox M UM-020

Страница 1: ...UM 020 Bugbox M User Manual Affix Serial Number Sticker Here...

Страница 2: ...s very affordable and maintenance costs are the lowest in the product class Features and Benefits Compact size Your personal workstation Quick and easy direct access with the gloveless cuffed Ezee Sle...

Страница 3: ...upply requirements 10 Voltage and frequency requirements 10 Power consumption 10 Powering the workstation 11 Workstation overview 12 Workstation layout 12 Component layout 12 Front view 12 Rear view 1...

Страница 4: ...Ezee Sleeves 23 Exiting the workstation chamber using the Ezee Sleeves 24 Arm gas displacement volume and pressure changes 24 Single Plate Entry System SPES 25 SPES overview 25 Using the SPES 26 Inter...

Страница 5: ...mains fuses 38 Service requirements 39 Spare parts and accessories 39 Overview 39 Spare parts and cleaning agents 39 Accessories 40 Workstation malfunction 41 Common problems and solutions 42 Worksta...

Страница 6: ...ator should be used for a bottled gas supply The maximum supply pressure permissible is 4 bar gauge The maximum permissible concentration of Hydrogen in the anaerobic mixed gas is 5 5 Hydrogen The mai...

Страница 7: ...the symbols found on the Bugbox M Figure 1 Bugbox M symbols Symbol Meaning Refer to user manual Alternating current O Off I On Primary earth connection This product complies with the essential EEA re...

Страница 8: ...osed of at a household waste site Instead it should be taken to the appropriate collection point for the recycling of electrical and electronic equipment Date of manufacture in format YYYY MM Installa...

Страница 9: ...60 mm Workstation chamber internal width 500 mm Workstation chamber internal height 420 mm Workstation chamber internal depth 460 mm Interlock internal width 100 mm Interlock internal height 200 mm In...

Страница 10: ...ge internal components of the workstation and will invalidate the warranty Electrical supply requirements The workstation must be connected to a mains power supply A power cord is supplied to connect...

Страница 11: ...re 12 To switch the workstation off press the power switch item 2 in Figure 12 Note A glove port should be left open when the workstation is switched off as the pressure inside the workstation will de...

Страница 12: ...love ports and the interlock The interlock consists of the interlock chamber with an inner and an outer door The Bugbox M workstation is controlled via the control panel Component layout Please famili...

Страница 13: ...Bugbox M UM 20 R4 0 Page 13 of 47 Bugbox M User Manual Rear view Figure 5 shows the rear view of the Bugbox M workstation Figure 5 Bugbox M workstation rear view...

Страница 14: ...ugbox M workstation left side view 1 Pressure relief tank cover pressure relief tank bung 2 Pressure relief tank 3 Pressure relief tank cover 4 Pressure relief tank overflow pipe 5 Vacuum port optiona...

Страница 15: ...ure 7 shows the right side view of the Bugbox M workstation Figure 7 Bugbox M right side view 1 Interlock outer door knob 2 Interlock outer door 3 Power entry panel 4 Serial number label 5 PAT test la...

Страница 16: ...on 2 Chamber light switch 3 Gas Alarm switch Press to switch the gas alarm on off 4 Humidistat Controls the level of humidity inside the workstation chamber 5 Lock active indicator LED Flashes to ind...

Страница 17: ...ure 0 1 C increments or humidity 5 Increase temperature 0 1 C increments or humidity For temperature control the white value PV Process Value is the actual temperature The green value SV Set Value is...

Страница 18: ...rge control Figure 11 Foot switch control panel 1 VAC for glove port vacuum control 2 LOCK for interlock purge control 3 SPOT for spotlight operation Power entry panel Figure 12 shows the power entry...

Страница 19: ...nnot be added after manufacture of the workstation Note Any equipment installed in the workstation chamber must be compatible with the humidity level inside the workstation chamber If in doubt consult...

Страница 20: ...To close the interlock outer door push the interlock outer door down The door latch will click to indicate that the door is closed Note Do not open the interlock outer door if the interlock inner door...

Страница 21: ...Ezee Sleeves see section 6 2 2 for more details Open the interlock inner door see section 6 1 3 for more details Remove the Petri dish holder from the interlock Close the interlock inner door see sect...

Страница 22: ...to the workstation chamber via the SPES and unloading the interlock Right hand glove port only for unloading the interlock For each method of entry the glove port selector knob Figure 10 must be set i...

Страница 23: ...Ezee Sleeves Repeat the procedure for the other hand if both hands are to enter the workstation chamber Press and hold the vacuum pedal with your foot item 1 in Figure 11 until the internal gas volum...

Страница 24: ...ort bar inside the glove port so that it is vertical Tighten the glove port cover knob Do not over tighten the glove port cover knob Supporting the Ezee Sleeve cuff with your opposite hand pull your h...

Страница 25: ...also known as the mailbox SPES overview The SPES consists of an external hinged flap and an internal hinged flap The external flap is held in place by a thumb screw when not in use The internal flap i...

Страница 26: ...Push materials through the SPES internal flap into the workstation chamber This should be done as quickly as possible to minimise gas loss from the workstation chamber When all materials have been add...

Страница 27: ...after each use Rear shelf The Bugbox M workstation has a rear shelf for additional storage within the workstation chamber The weight limit for the shelf is 5 5kg The weight on the shelf must be evenly...

Страница 28: ...nd Turn the grey collar anti clockwise counter clockwise to loosen the cable gland Remove the red plug Push the cable through the cable gland Tighten the grey collar by turning clockwise until tight D...

Страница 29: ...m Petri dishes The vacuum port is located on the left hand side of the workstation item 3 in Figure 6 To use the vacuum port Connect the vacuum source to the external part of the vacuum port by pushin...

Страница 30: ...UM 20 R4 0 Page 30 of 47 Bugbox M User Manual Online video user guides Further information and demonstrations can be found at Ruskinn Technology Limited s YouTube channel http www youtube com ruskinnt...

Страница 31: ...or Tristel Duo Foamer Tristel Fuse Sachets and Duo Foamer are available from Ruskinn Technology Limited see section 7 4 2 for details Ruskinn Technology Limited anti static cleaner Distilled water No...

Страница 32: ...terlock inner door o The glove port covers o The inside of the SPES For all workstation components wipe with a paper towel soaked in an appropriate cleaning agent Take care not to get cleaning agents...

Страница 33: ...mation Either open the SPES see section 0 or open one of the glove port covers see section 6 2 2 to equalise the pressure between the workstation chamber and the external environment Remove the pressu...

Страница 34: ...ws the O ring removal Figure 25 O ring removal Remove the Ezee Sleeve To install an Ezee Sleeve Place the new Ezee Sleeve onto the glove port ensuring that the O ring grooves are completely covered an...

Страница 35: ...leeves see section 7 2 2 for more information Undo the glove port covers and place on the rear shelf Lift the floor tray at the front to expose the detox sachets Figure 26 shows the location of the sa...

Страница 36: ...facility Return the ICO2N2IC to the main menu Switch off Bugbox M and disconnect from the mains power supply Remove the Ezee Sleeves see section 7 2 2 for more information Undo the glove port covers...

Страница 37: ...s power supply Remove the plug from the mains socket Using a small flat bladed screw driver remove the fuse cover from the mains plug Figure 27 shows the fuse removal Figure 27 Mains plug fuse removal...

Страница 38: ...val of the mains fuse holder Figure 28 Mains fuse holder removal Replace the mains fuses The fuse ratings are o 240V 50Hz F3 15A H250V o 220V 60Hz F3 15A H250V o 110V 60Hz F5A H250V o 100V 50 60Hz F5A...

Страница 39: ...the biennial service includes an annual service Note The annual service includes the replacement of the detox and the catalyst sachet Service contracts are available for all Ruskinn Technology Limited...

Страница 40: ...gbox M workstation Figure 31 is the list of accessories for the Bugbox M workstation Please contact your local distributor for the latest pricing and availability Figure 31 Bugbox M accessories Item D...

Страница 41: ...lease contact your local distributor quoting the serial number of your workstation If the problem is related to the ICO2N2IC please download the event log to a USB device see UM 011 ICO2N2IC user manu...

Страница 42: ...fuse has blown Contact your local distributor Devices plugged into the internal socket are not powering up The power switch on the device is not switched on The plug for the device is not fully insert...

Страница 43: ...he workstation chamber In normal operation the gas demand indicator should not illuminate more than once every 20 minutes when the workstation is at rest At rest is defined as the gasses are within de...

Страница 44: ...details Contact your local distributor The gas mixer alarm is sounding A gas cylinder is empty Check the ICO2N2IC gas mixer screen to see which gas cylinder is empty An empty cylinder will be indicat...

Страница 45: ...F FITNESS FOR A PARTICULAR PURPOSE THE IMPLIED WARRANTY OF MERCHANTABILITY OR ANY IMPLIED WARRANTY ARISING OUT OF A COURSE OF DEALING OR OF PERFORMANCE CUSTOM OR USAGE OF TRADE Ruskinn Technology Limi...

Страница 46: ...be disposed of at a household waste site Instead it should be taken to the appropriate collection point for the recycling of electrical and electronic equipment Alternatively please contact your local...

Страница 47: ...ales ruskinn com Technical support techsupport ruskinn com General enquiries ruskinnoffice ruskinn com Website www ruskinn com YouTube channel http www youtube com ruskinntechnology Ruskinn Technology...

Отзывы: