1. 

Y237 Operation

 

The Y237 adaptor is a mechanical component designed to be mounted on Dresser Produits 
Industriels S.A.S. electrical instruments 

only

The type Y237 cable entry adaptor allows the installation of 2 (or 3) cable glands of a certified type 
Ex db IIC and Ex tb IIIC on hou

sing that are only equipped with a ½” NPT or ¾” NPT conforms to 

ANSI/ASME B1.20.1. 

This document defines the requirements for safe installation and operation of the Y237 on an 
electrical instrument according to 

ATEX 2014/34/EU directive

The essential health and safety requirements stated into annex II of the 2014/34/EU Directive has 
been satisfied. 

 

 

2. General requirements 

  The 12400 has been built with respect of the following standards:  

  ATEX: EN 60079-0, EN 60079-1, EN 60079-31 

  IECEx: IEC 60079-0, IEC 60079-1, IEC 60079-31 

  Maximum Operating temperature range: -55°C to +85°C. 

 

 

3. Numbering System 

  This adaptor is identified: 

Y237 

  A suffix indicates the type of male and female threading as well as the material used according to 

the variants of the table below: 

Y237 - 

Material 

Male 

Female

1

 

A-

 Aluminum 

S-

 Stainless Steel 

1- 

½’’ NPT 

2- 

¾’’ NPT 

1- 

½’’ NPT 

2- 

¾’’ NPT 

3- 

M20 

 

 

1

The three female inputs are identical on the Y237. 

 

Содержание Masoneilan Y237

Страница 1: ...Baker Hughes Data Classification Public Masoneilan Y237Model Adaptor for Multiple Cable Entries ATEX Instruction Manual Rev B...

Страница 2: ...REQUIREMENTS FOR OPERATION OF OTHER EQUIPMENT AT THE SITE THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN...

Страница 3: ...Adaptor ATEX Instruction Manual 3 Table of Contents 1 Y237 Operation 5 2 General requirements 5 3 Numbering System 5 4 Marking 6 5 Installation and electrical connections 7 6 Maintenance and service 7...

Страница 4: ...Installed put into service and maintained by qualified and competent professionals who have undergone suitable training for instrumentation used in areas with potentially explosive atmosphere Such tr...

Страница 5: ...f the Y237 on an electrical instrument according to ATEX 2014 34 EU directive The essential health and safety requirements stated into annex II of the 2014 34 EU Directive has been satisfied 2 General...

Страница 6: ...Dresser Produits Industriels S A S 14110 CONDE SUR NOIREAU FRANCE Type designation Y237 See numbering system 3 for complete codification Basic marking II 2 G D Complementary marking Ex db IIC Gb et E...

Страница 7: ...minum S Stainless Steel 3 NPT 4 NPT 4 NPT 5 NPT 6 M20 1 The three female inputs are identical on the Y237 If one Y237 input is not used the conduit will be closed by a plug if apparatus certified ATEX...

Страница 8: ...end user with respect to the mounting rules defined in the Annex 7 11 For use in dusty hazardous areas zone 21 22 the user will have to proceed to a cleaning regularly the different sides of the enclo...

Страница 9: ...iciency Cemented with Loctite 5400 low strength thread sealant or equivalent product with similar efficiency This is mandatory to meet an IP67 Tightening torque see Cable Gland instruction manual Chec...

Страница 10: ...erhughes com Copyright 2021 Baker Hughes Company All rights reserved Baker Hughes provides this information on an as is basis for general information purposes Baker Hughes does not make any representa...

Отзывы: