1.
Y237 Operation
The Y237 adaptor is a mechanical component designed to be mounted on Dresser Produits
Industriels S.A.S. electrical instruments
only
.
The type Y237 cable entry adaptor allows the installation of 2 (or 3) cable glands of a certified type
Ex db IIC and Ex tb IIIC on hou
sing that are only equipped with a ½” NPT or ¾” NPT conforms to
ANSI/ASME B1.20.1.
This document defines the requirements for safe installation and operation of the Y237 on an
electrical instrument according to
ATEX 2014/34/EU directive
.
The essential health and safety requirements stated into annex II of the 2014/34/EU Directive has
been satisfied.
2. General requirements
•
The 12400 has been built with respect of the following standards:
▪
ATEX: EN 60079-0, EN 60079-1, EN 60079-31
▪
IECEx: IEC 60079-0, IEC 60079-1, IEC 60079-31
•
Maximum Operating temperature range: -55°C to +85°C.
3. Numbering System
•
This adaptor is identified:
Y237
•
A suffix indicates the type of male and female threading as well as the material used according to
the variants of the table below:
Y237 -
Material
Male
Female
1
A-
Aluminum
S-
Stainless Steel
1-
½’’ NPT
2-
¾’’ NPT
1-
½’’ NPT
2-
¾’’ NPT
3-
M20
1
The three female inputs are identical on the Y237.