background image

Masoneilan 5A Series Double-Acting Cylinder Actuator Manual 

 |  5

© 2020 Baker Hughes Company. All rights reserved.

2.  Maintenance

Preventive maintenance of double-acting cylinder actuators 

is to check the shaft for damage such as an o-ring and 

prevent premature wear. Replacement o-rings can be 

obtained through our agency or sales office. If problems 

occur during maintenance, please contact our factory.

Also pay utmost attention to the sliding surface damage and 

surface roughness of the cylinder internal diameter.

Pay particular attention to:
•  Burrs and surface roughness of the O-ring groove 
•  Burrs, sliding part damage, 
•  Surface roughness of the piston rod 
•  Damage and deterioration of the O-ring 
•  Sliding part damage of the piston

3.  Reassembly

Follow the procedure below to reassemble after necessary 

maintenance or to change the mounting position of the valve 

and actuator.

A. 

Determine the correct mounting position for 

the valve and actuator. 

B. 

If necessary, change the mounting positions 

of the body stud (28) and packing flange stud 

(13).

C. 

Make sure the grommet (12) and shaft 

bearing (8) are mounted on the yoke. Rotate 

the shaft and seat the plug.

D. 

Insert the yoke and packing flange (14) into 

the shaft (19).

Note:  Insert the packing flange (14) into the 

shaft (19) with the concave side facing  

the packing (17).

E. 

Make sure that the groove on the packing 

flange (14) fits into the packing flange stud 

(13).

F. 

With the packing flange on the shaft, pass the 

shaft through the grommet (12) of the yoke 

(33).

G. 

Put the lever on the shaft so that the boss on 

one side of the shaft hole of the lever (34) 

faces the shaft bearing (8), and engage the 

spline.

H. 

Completely insert the shaft into the shaft 

bearing (8). 

I. 

Install and tighten body stud nut (27). 

J. 

Attach the packing flange stud nut (13A) and 

tighten it with your finger.

K. 

Move the lever (34) on the shaft (19) towards 

the body and tighten the lever cap screw (49)

L. 

Pull the shaft, along with the lever, firmly 

towards the shaft bearing of the yoke to 

engage the shaft shoulder and shaft bearing.

M. 

Loosen the lever cap screw (49), move the 

lever (34) to the position where it hits the shaft 

bearing (8), and tighten the lever cap screw 

again.

N. 

As shown in Figure 2, be sure to install the 

cylinder on the left side of the yoke and fix 

it with the four cap screws (36) and lock 

washers (37).

O. 

Proceed to the next section, Actuator Stem 

Adjustment.

When the yoke is installed, the body stud (28) 

(shorter stud) must be in the opening of the yoke.

CAUTION

When the plug is fully closed, engage the shaft and 

lever so that the lever indicator dot indicates the 

fully closed position. Temporarily attach the front 

cover and check the position of the indicator dot. 

If the fully closed position indicator line on the 

front cover is not aligned with the indicator dot, 

reposition the lever.

CAUTION

Содержание Masoneilan 5A Series

Страница 1: ...Masoneilan 5A Series Double Acting Cylinder Actuator for Rotary Valves Instruction Manual Rev A Baker Hughes Data Classification Public ...

Страница 2: ...EQUIREMENTS FOR OPERATION OF OTHER EQUIPMENT AT THE SITE THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN CONNECTION WITH INSTALLATION OPERATION OR MAINTENANCE SHOULD FURTHER INFORMATION BE DESIRED OR SHOULD PARTICULAR PROBLEMS ARISE WHICH ARE NOT COVERED SUFFICIENTLY FOR THE CUSTOMER OPERATOR S PURPOSES TH...

Страница 3: ... Baker Hughes Company All rights reserved Table of Contents Safety Precautions iv Introduction 1 Description 1 1 Actuator Disassembly 2 4 2 Maintenance 5 3 Reassembly 5 4 Actuator Adjustment 6 5 Actuator Operation Change 7 6 Installing the Handwheel 7 Parts Reference 8 ...

Страница 4: ...t can lead to injury or death Total compliance with all DANGER WARNING and CAUTION notices is required for safe operation CAUTION DANGER WARNING This is the safety alert symbol It alerts you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death Indicates a potentially hazardous situation which if not avoided could result in death or...

Страница 5: ...double acting actuator offered for Globe Rotary Valves It offers high capacity while providing excellent seat leakage performance in both directions The ability to quick removal and replacement of the valve components during maintenance saves valuable plant downtime This manual is a supplementary explanation of the instruction manual regarding the installation removal and maintenance of the Double...

Страница 6: ...or support to the actuator F Loosen the cap screw 36 and lock washer 37 holding the cylinder 71 and remove it G Remove the cylinder 71 from the yoke 33 H Loosen the lever cap screw 49 I Remove the packing flange stud nut 13A J Install the lift or support on the yoke 33 K Loosen the body stud nut 27 L Remove the yoke from the body M Refer to Figure 4 to determine the desired mounting position of th...

Страница 7: ...er Actuator Manual 3 2020 Baker Hughes Company All rights reserved 1 Actuator Disassembly Cont see Figures 1 3 Remove the yoke 33 lever 34 and packing flange 14 together WARNING Figure 1 Figure 2 Travel indicator dot Mark on yoke for assembly ...

Страница 8: ...assembly Cont see Figures 1 3 Figure 3 Note The actuator is always mounted on the left side of the yoke with the valve closed when the actuator stem retracts Installation is limited to the locations shown Mounting positions limited to 2 only Figure 4 F T C F T O Plug Position ...

Страница 9: ... 17 E Make sure that the groove on the packing flange 14 fits into the packing flange stud 13 F With the packing flange on the shaft pass the shaft through the grommet 12 of the yoke 33 G Put the lever on the shaft so that the boss on one side of the shaft hole of the lever 34 faces the shaft bearing 8 and engage the spline H Completely insert the shaft into the shaft bearing 8 I Install and tight...

Страница 10: ...y F Manually move the lever 34 to the fully closed position G The clevis pin hole of the lever 34 and the hole of the clevis 35 should be assembled H Move the lever to the fully open position I Depending on the actuator mode either apply or release air pressure to the actuator move the end bearing lock nut 46 to a position where it can be reached and loosen the lock nut 46 J Rotate the rod end bea...

Страница 11: ...ndwheel on the yoke both the sides higher diameter wheel installed opposite to actuator and lower diameter wheel installed on the actuator side see Figure 2 The handwheels can be easily removed by removing the toruarc ring 50 Also after installing the handwheel return the handwheel until the washer 51 hits the yoke lightly and fix it with the handwheel lock 52 at that position Note When using the ...

Страница 12: ... the registered trademarks or trademarks of their respective owners BHMN 5A Actuator IOM 34584A 0820 08 2020 Parts Reference Ref Part name Ref Part name Ref Part name 1 Body 29 Rear cover 58 Boss cover 2 Seat ring 30 Cover screw 60 Cover Flange 3 Retainer 31 Screw retainer 61 Gasket 4 Plug 32 Front cover 64 Stud 5 Clevis pin plug 33 Yoke 67 Stud 6 indicator dot 34 Lever 68 Nut 7 Clevis pin 35 Clev...

Отзывы: