14 | Baker Hughes
Copyright 2020 Baker Hughes Company. All rights reserved.
Type 51/52/53 Cylinder Actuators
Connecting Double Acting (Model 51) (Figures 13)
1. Install actuator on the valve body with drive nut.
2. Connect manual loading panel tubing to the Top Plate (17).
3. Apply required air pressure through the manual loading panel
to completely extend the actuator stem.
4. Reconnect manual loading panel tubing from the Top Plate
(17) to the Yoke (1), which is integrated into the bottom plate
connection.
5. Retract the actuator stem either pneumatically or with a
handwheel approximately 1” (2mm) using the visual stroke
scale as shown in Figure 11.
Figure 11
6. Assemble the Split Clamp (22).
Note: If the split clamp does not engage with both
stems, then retract the actuator stem until alignment and
engagement is achieved.
CAUTION
CAUTION
WARNING
DANGER
Make sure the valve is fully extended. Use caution to
keep appendages clear of pinch points.
Figure 12
7. Assemble and tighten Indicator Arm (23), Spring Lock
Washers (25), and Hexagon Bolts (24).
8. Line up the indicator plate (26), with Indicator arm (23) and
check actuator for proper operation.
Connecting Air to Extend (Model 52)
(Figure 14)
1. Install actuator on the valve body with drive nut.
2. Connect manual loading panel tubing to the top plate (17).
3. Apply required air pressure through the manual loading panel
to completely extend the actuator stem.
4. Retract the actuator stem either pneumatically or with a
handwheel approximately .1” (2mm) using the visual stroke
scale as shown in Figure 11.
5. Assemble the Split Clamp (22).
Note: If the split clamp does not engage with both
stems, then retract the actuator stem until alignment and
engagement is achieved.
CAUTION
CAUTION
WARNING
DANGER
Make sure the valve is fully extended. Use caution to
keep appendages clear of pinch points.
6. Assemble and tighten Indicator Arm (23), Spring Lock
Washers (25), and Hexagon Bolts (24).
7. Line up the indicator plate (26), with Indicator arm (23) and
check actuator for proper operation.
Connecting Air to Retract (Model 53)
(Figure 15)
1. Install actuator on the valve body with drive nut.
2. Connect manual loading panel tubing to the yoke (1), which is
integrated into the bottom plate connection.
3. Retract the actuator stem either pneumatically or with a
handwheel approximately .1” (2mm) using the visual stroke
scale as shown in Figure 11.
4. Assemble the Split Clamp (22).
Note: If the split clamp does not engage with both stems,
retract the actuator stem until alignment and engagement
is achieved.
CAUTION
CAUTION
WARNING
DANGER
Make sure the valve is fully retracted. Use caution to
keep appendages clear of pinch points.
5.
Assemble and tighten Indicator Arm (23), Spring Lock
Washers (25), and Hexagon Bolts (24).
6.
Line up the indicator plate (26), with Indicator arm (23) and
check actuator for proper operation.
.1
” (2mm)