Bake Max TCO6G Скачать руководство пользователя страница 77

1

10

10

10

3

5

9

9

9

2

11

12

13

14

15

10

8

13

12

6

4

5

12

12

4

6

12

10

10

12

7

Item

Description

Model

Code

1

COOLER

ALL

4.02.12.00028290

2

WIRE PASS

ALL

2.80.57.02021151

3

SAFETY THERMOSTAT MANUAL RESET

ALL

2.80.49.00000355

4

BTWP TERMINAL 6/10T-AZ

ALL

4.02.12.00006120

5

BTWP TERMINAL 6/10T-CZ

ALL

4.02.12.00006121

6

BTWP TERMINAL 6/10T-VD/AM

ALL

4.02.12.00006119

7

COMPENSATOR

ALL

3.97.01.10000889

8

THREE PHASE WIRING 240V

TRIF 240V

2.80.11.07013222

9

CONTACTOR/BREAKER FIXING RAIL

ALL

4.02.08.00004454

10

WIRE PASS

ALL

2.80.57.01000173

TCO 6/7

8.02.13.00000164

TCO 10/12

8.02.13.12000045

12

END POST

ALL

4.02.12.10289060

13

CIRCUIT BREAKER

ALL

2.80.13.00050101

CONTACTOR CWMC32-10-30V 15

TCO 6/7 TRIF 240V

4.02.12.56485999

CONTACTOR CWM50-11 127V 50/60HZ

TCO 10/12 TRIF 240V

4.13.01.35502385

15

FREQUENCY INVERTOR

ALL

2.80.02.00047767

ELECTRIC PANEL TCOE

11

14

CONTROL PANEL SUPPORT

Содержание TCO6G

Страница 1: ...Combi Oven Touch TCO6G MODELS TCO6E TCO7G TCO7E...

Страница 2: ...rating or servicing this equipment NOTICE Instructions must be posted in a prominent location that will provide the user of this equipment with procedures in the event he she smells and or detects gas...

Страница 3: ...forms best please read this manual carefully and follow the instructions correctly If you have any doubts and or suggestions call Ven ncio qualified professionals will be at your disposal RECEIPT We r...

Страница 4: ...y and power are in accordance with the points installed This equipment is a convertible voltage DO NOT ATTEMPT TO CHANGE THE VOLTAGE as it may be severely damaged and is not covered under warranty If...

Страница 5: ...ible to touch Model TCO6G TCO7G TCO6E TCO7E TCO10G TCO12G TCO10E TCO12E No of Meals Approx 350 Approx 350 Approx 500 600 Approx 500 600 Gas 0 8 1 2 Three phase voltage V 220 380 440 220 380 440 Single...

Страница 6: ...y case to connect other devices in the same socket outlet Doing so may cause overloading of the electrical installation and or poor contact Overloads can cause harmful heating to the insulation connec...

Страница 7: ...er and fuse see table of circuit breakers according to the type of equipment Electric power socket outlet see power grid Socket outlet see power grid Point for drainage of water drain or sewage Refer...

Страница 8: ...tions regarding the proper installation and or operation of this oven please contact your local distributor Quali ed installation personnel are individuals a rm or a company which either in person or...

Страница 9: ...ENANCE SERVICE REPAIRS OR INSTALLATION Contact your dealer or the factory for your local Factory Authorized ServiceAgency The gas pressure regulator provided with the equipment must be installed when...

Страница 10: ...g gas ori ces when gas pressure is applied Compounds used on threaded joints of this appliance piping must be resistant to the action of NG and LP gas and provide a gas tight seal to prevent leaks Whe...

Страница 11: ...e unit during power failure Before lighting check all joints in the gas supply line for leaks Do not use an open ameto check for leaks 1 Turn pilot valves to OFF position by turning adjustment screws...

Страница 12: ...pe dope on the threads of the valve DO NOT APPLY PIPE DOPE INTO ORIFICE HOOD 5 Attach the supplied propane burner ori ce hoods with a 1 2 wrench 6 Convert the pressure regulator from Natural to Propan...

Страница 13: ...y other than certi ed licensed personnel will void the warranty and will result in damage to the oven and or injury to the operator To avoid burning do not use any liquid or containers loaded with pro...

Страница 14: ...the turbine is for both sides in order to guarantee the best cooking only in eletric model OVEN LEVELING The oven has adjustable feet for easy leveling INSTALLATION EXAMPLE OF THE COMBI OVEN TOUCH AND...

Страница 15: ......

Страница 16: ...oven Eg meats potatoes Maximum capacity TCO6 30 kG 2 Pre heating It is extremely important that the oven is preheated especially for foods where the cooking time is less than 30 minutes This function...

Страница 17: ...C Loin poultry etc Between 170 C to 180 C 6 Containers Grills For whole chickens grilled fried roasted and base for common baking trays Flat GNs Use up to 65mm deep to cook rice and foods in which th...

Страница 18: ...Enamel Coated Stainless Steel GN 20mm high GN to fry eggs and hamburger GASTRONORM LINE ACCESSORIES GN for 06 Whole Chickens...

Страница 19: ...Perforated GN 65 mm Deep perforated GN 65 mm deep Flat GN 65 mm Deep...

Страница 20: ...GN to Fry French Fries Metal rgica Ven ncio manufactures all the accessories used by the Combi oven Flat Beaded Aluminum GN...

Страница 21: ...ent carefully before installation and before using the device and follow all warnings Please keep this document with your device for future reference Important Use the device only in the ways describe...

Страница 22: ...screen TFT graphic display and guarantees an IP65 degree of protection for agile cleaning DIMENSIONS AND INSTALLATION User Interface Dimensions The following drawing illustrates the dimensions of the...

Страница 23: ...allation of the control module The following drawing illustrates the dimensions of the device s control module the dimensions are expressed in mm in The installation is planned on a flat surface with...

Страница 24: ...touching the reference area Control panel fan The technical compartment fan is switched on until the operating temperature of the control module reaches the set temperature with parameter F6 and is s...

Страница 25: ...escription of the washing typology There are 3 management relays dedicated to Relay K10 solenoid valve for introducing water from condenser water network Relay K11 pump with recirculating water system...

Страница 26: ...our washing typologies Cycle selection and start In case a RINSEN cycle is selected and started the cycle will be immediately placed in the pre wash phase If on the other hand one of the other 3 types...

Страница 27: ...temperature constant After the time has elapsed the operation of the washing system will vary according to the type of cycle defined RINSEN i e WASHING cycle Phase 2A RINSEN After the pre wash phase i...

Страница 28: ...ashing cycle During the entire washing phase if enabled via parameter P3 and if the value of the Water Drain probe is higher than the maximum water flow set point 70 C the controller will activate the...

Страница 29: ...p immediately If the cycle is manually stopped during phase 3B the cycle will go to phase 4B and then to phase 4B once it is completed If the cycle is otherwise manually stopped during phase 4B the cy...

Страница 30: ...e with the alarm buzzer ON by informing in the controller screen PF If a power interruption occurs during a cooking cycle and the duration of the interruption is less than the time set at 240 minutes...

Страница 31: ...of the cooking cycle Set point of operation during the first phase of the cooking cycle set point of operation during the preheating During the preheating the fan is turned on at full speed When the...

Страница 32: ...s enabled i e if the parameter P2 is set to 1 the phase lasts until the temperature detected by the needle probe reaches the set point inside and the operating set point is an absolute value the set p...

Страница 33: ...and 6 To set the phase duration operate as follows 11 Touch the option 12 Repeat steps 5 and 6 To set the set point of the inner core probe operate as follows 13 Touch the option 14 Repeat points 5 an...

Страница 34: ...Setting the cooking cycle Setting the cooking type Setting the operating set point...

Страница 35: ...ows 23 From any component phase the cycle 24 Touch the Finish recipe option Once the program definition is complete the controller will display a summary screen of the defined cycle Through this scree...

Страница 36: ...Cycle setting screen Defined cycle summary screen...

Страница 37: ...paragraph 8 2 Setting the cooking cycle to open close the vent not used in this version to switch on off the ambient light to display the value of process variables and machine status At the conclusi...

Страница 38: ...Start of cooking cycle and Preheating End or interruption of the cooking cycle Extension of the cooking cycle...

Страница 39: ...e operating as follows 1 Set the cooking cycle see Setting the cooking cycle 2 Touch SAVE Go to My recipes screen from where you can select the recipe to be saved 3 Touch or to go through the pages wi...

Страница 40: ...Cycle summary screen to access My recipes My recipes screen Recipe replacement screen...

Страница 41: ...Ensure that the device is activated and no procedure is in progress 2 Touch the recipes option 3 Touch or to select the recipe 4 Touch the display next to the recipe of interest 5 Touch The recipe wil...

Страница 42: ...Access a recipe Cancellation of a recipe To cancel a recipe operate as follows 1 From point 4 Starting a recipe touch delete to cancel the reference recipe...

Страница 43: ...following table shows the factory settings of the regeneration cycle inside The following table shows the factory settings of the regeneration cycle in time DEFINITION DEFAULT MINIMUM MAXIMUM Operatin...

Страница 44: ...Operating set point 30 C parameter r11 0 500 C fan speed Minimum without reversing direction of travel if provided vent opening at the beginning of the cycle during the whole duration start of a speci...

Страница 45: ...Access to a special cycle Start of a special cycle...

Страница 46: ...Setting the cooking cycle in this case the last cycle can be started recipes from My recipes function operating cycles of the Special Cycles function Start of a preferred cycle To start a preferred cy...

Страница 47: ...FUNCTION Setting the Weekly Scheduled Activation function To access the procedure operate as follows 1 Ensure that at least one recipe is stored that the device is activated and there is no procedure...

Страница 48: ...set the minutes touch the display near the center touch or within 15 sec to decrease or increase the value of interest 9 Touch the option to confirm the value entered To set the recipe to start from...

Страница 49: ...s set that the device is activated and there is no procedure in progress 2 Touch for 1 sec To select an activation operate as follows 3 Touch or To change an activation operate as follows 4 Repeat ste...

Страница 50: ...Access to the activation procedure of the Weekly scheduled activation function Selecting an activation and activating the Weekly scheduled activation function...

Страница 51: ...iables and machine status To access the procedure operate as follows 1 Ensure that the device is activated and no procedure is in progress 2 Touch 3 Touch INTERNAL VALUES Setting the language used on...

Страница 52: ...and no procedure is in progress 2 Touch To select a value operate as follows 3 Touch the repeat until the green rectangle indicates the desired value To set a value operate as follows 5 Touch or to c...

Страница 53: ...4 Touch or to set the password 19 5 Touch to confirm To select a parameter operate as follows 6 Touch or to select the desired parameter To set a parameter operate as follows 7 Touch the desired para...

Страница 54: ...0 Needle probe offset CA3 25 50 25 50 C F 2 0 Steam reduction probe offset PARAMETER MINIMUM MAIN REGULATOR r0 1 99 C F 2 5 Operating set point differential referred to the temperature detected by th...

Страница 55: ...perature detected by the ambient sensor r12 0 240 min 240 Duration of a power interruption occurring during the cooking cycle causing the interruption 3 c0 1 120 s 10 duration of the buzzer activation...

Страница 56: ...n only if F0 1 2 or 3 0 SI F4 0 F5 0 Minimum fan speed included as percentage of maximum speed only if F0 3 F5 F4 100 100 Maximum fan speed included as percentage of maximum speed only if F0 3 F6 20 6...

Страница 57: ...injection t6 t7 999 s 60 Cycle time for the injection of steam generated with an external humidifier t7 0 t6 s 30 Duration of steam injection generated with an external humidifier corresponding to max...

Страница 58: ...ion is enabled t17 1 500 C F 2 95 Operating temperature of the boiler steam t18 1 500 C F 2 70 Boiler steam maintenance temperature t19 1 99 C F 2 2 Hysteresis by t17 t18 t20 0 240 s 2 Boiler water lo...

Страница 59: ...1 normally closed active input with open contact i1 0 1 0 Fan thermal protection input type 0 normally open active input with closed contact 1 normally closed active input with open contact i2 0 1 0...

Страница 60: ...MAXIMUM MEASUREMENT UNIT DEFINITION SERIAL NETWORK LA 1 247 247 Device address Lb 0 3 2 Baud rate 0 2 400 baud 1 4 800 baud 2 9 600 baud 3 19 200 baud LP 0 2 2 Parity 0 none 1 odd 2 even PARAMETER MIN...

Страница 61: ...t wash Short rinse time Operating set point in the drying liquid phase Operating set point for washing preparation in tablet wash Introduction time of drying liquid Activation time of the water pump a...

Страница 62: ...ngs contained in the programs To upload the settings contained in the programs operate as follows 1 Ensure that the device is deactivated and no procedure is in progress 2 Insert a USB key containing...

Страница 63: ...ined in the configuration parameters To download the settings contained in the programs operate as follows 1 Ensure that the device is deactivated and no procedure is in progress 2 Insert a USB key in...

Страница 64: ...meter r12 when the power is restored the cycle will be resumed from the beginning of the phase during which the interruption will have been triggered If vice versa the duration of the interruption is...

Страница 65: ...a cooking cycle the cycle will be interrupted the vent will open the fan of the technical compartment will be turned on and the permanent outputs will be deactivated Micro port input alarm Resources c...

Страница 66: ...oid Steam production is not started or is insufficient The oven switches itself off Fuse blown Replace fuse Alarm lack of water Tap or valve of place closed Open the valve or wait for a new supply Cha...

Страница 67: ...s for the analog inputs digital inputs and analog output should be less than 10 m 32 808 ft The maximum length of user interface control module connection cables should be less than 10 m 32 808 ft Ope...

Страница 68: ...1 F Protection none Digital Inputs 5 inputs 2 micro port and rotor stand end time set via the normally open normally closed configuration parameter clean contact 5 VCC 0 5 mA 3 thermal protection fan...

Страница 69: ...ement 1 1A output res 250 VCA di SPST type K10 configurable for plant setting for washing water valve management 1 1A output res 250 VCA di SPST type K11 configurable for plant setting for washing liq...

Страница 70: ......

Страница 71: ...P FLANGE ALL 8 02 13 00000167 22 LAMP GLASS ALL 2 80 09 00020155 23 LAMP SILICON SEAL ALL 2 80 60 03000528 24 LAMP ALL 2 80 26 00056422 25 LAMP SOCKET 12V 50W ALL 4 02 12 00000008 26 NOZZLE BODY NUT A...

Страница 72: ...02 13 12002500 TCO 6 7 8 02 13 07005100 TCO 10 12 8 02 13 12002600 49 EXTERNAL CHUTE ALL 8 02 13 00003800 50 FRONTAL OUTER LOWER CLOSING ALL 8 02 13 07000031 TCO 6 7 GAS TCO 10 12 GAS TCO 6 7 ELET TC...

Страница 73: ...T CZ ALL 4 02 12 00006121 6 BTWP TERMINAL 6 10T VD AM ALL 4 02 12 00006119 7 GAS WIRING TCOG 2 80 11 07001222 8 COMPENSATOR ALL 3 97 01 10000889 9 CONTACTOR BREAKER FIXING RAIL ALL 4 02 08 00004454 10...

Страница 74: ...TCO 10 12 2 90 03 00150817 TCO 6 7 8 02 13 07000080 TCO 10 12 8 02 13 12000044 3 TOUCH SCREEN BOARD 338L ALL 2 80 11 00020671 4 SENSOR SUPPORT ALL 8 02 13 07000082 5 MAGNETIC SWITCH ALL 2 80 25 000230...

Страница 75: ...8160 ORIFICE HOOD N 56 LPG 8 27 05 02588115 TCO 6 7 8 02 13 07006400 TCO 10 12 8 02 13 12002900 7 MANIFOLD FASTENER ALL 8 02 13 07000085 8 UNIVERSAL IGNITOR ALL 4 02 12 00050842 9 FLAME SENSOR ALL 2 8...

Страница 76: ...UPPORT RUBBER ALL 2 80 60 00006049 TCO 6 7 8 02 13 07006600 TCO 10 12 8 02 13 12002200 6 HANDLE ALL 8 97 01 84179000 7 BESEL ALL 8 02 13 00000241 8 INNER GLASS LOCK ALL 8 02 13 03010014 9 DOOR SHUTE O...

Страница 77: ...ALL 4 02 12 00006119 7 COMPENSATOR ALL 3 97 01 10000889 8 THREE PHASE WIRING 240V TRIF 240V 2 80 11 07013222 9 CONTACTOR BREAKER FIXING RAIL ALL 4 02 08 00004454 10 WIRE PASS ALL 2 80 57 01000173 TCO...

Страница 78: ...1 2 4 3 5 6 7 8 9 12 23 11 19 22 19 24 9 9 13 15 14 17 15 18 16 20 20 10 12 6 21 6 25 26 27 28 29 31 30...

Страница 79: ...80 60 03000531 13 SMALLER BOX ASSY ALL 8 02 13 00002900 14 HOSE 1 1 2 ALL 2 80 27 01000288 15 CLAMP 14 32 44 ALL 2 80 01 09020805 16 SMALLER BOX ASSY ALL 8 02 13 00002800 17 HOSE 1 1 4 ALL 2 80 27 01...

Страница 80: ......

Страница 81: ...7000057 19 WATER PRESSURE REGULATOR ALL 4 02 12 05170681 20 HOSE 10x4 2x1250mm ALL 2 80 27 37015010 21 CONNECTOR 1 2 NPT x 5 8 NPS ALL 8 02 13 00000254 22 SMALL BOX ASSY ALL 8 02 13 00002900 23 HOSE 3...

Страница 82: ...y inversor 12V input Interface Module Standard not applied ground wire USB port Control Module RS 485 MODBUS input breaker Washing Water injection Safety Thermal Switch motor protection Reserved Drain...

Страница 83: ...4 13 12 11 10 09 08 07 M INV1 Frequency Inverter A12 GND GND D14 D15 D16 A0 D0 R13 R14 R24 4 5 13 14 15 16 18 20 22 26 1 2 3 6 8 9 10 25 24 10V AI1 GND 24V GND DI1 DI2 DI3 A B R2 R22 07 Common 08 PTC...

Страница 84: ...eam out then open the entire door Do not spray water from the spray head on the door glass or lights unless the temperature is below 90 C The glass can break Every time before starting the device make...

Страница 85: ...after manual cleaning to wash cleaning products Failure to do so may result in damage to the surface of the cooking chamber and its discoloration during the following use at high temperatures Such dam...

Страница 86: ...e leads and the heating elements After cleaning the cooking chamber of the device start cleaning Under no circumstances should the temperature exceed 70 C Repeat the process if necessary Rinse the doo...

Страница 87: ...tenance instructions helps to significantly extend the life of the device and ensures its smooth operation Annual Maintenance Perform quarterly maintenance It is also necessary to check the installati...

Страница 88: ...y 12 months of operation This verification must be carried out by the technicians of a service company authorized by BAKEMAX The customer is required to produce a record of such service events Strict...

Страница 89: ...glass light bulbs resistors contactors fuses relays solenoids digital controllersandthermostats arenotcoveredbythiswarranty In the case of its electric motors being manufactured by a third party when...

Страница 90: ...______________________ State ______________ _____________________________________ Signature Buyer Cut out 2nd COP OF THE BUYER COMPLETE ALL FIELDS WITH A LEGIBLE CAPITAL LETTER Owner _________________...

Страница 91: ......

Страница 92: ...170 Millennium Blvd Moncton NB E1E2G8 3601 Pinnacle Point Dr Dallas TX 75211 Toll Free 1 800 565 BAKE 2253 Telephone 1 506 858 8990 Fax 1 506 859 6929 E mail sales bakemax com Web site www bakemax com...

Отзывы: