66
66
Installation:
Must be away from inductive and capacitive interference source as conductor, relays,
1.
engines, switch power pack clocked controllers, etc..
Must be wired separately from heavy-duty current wires.
2.
Must be kept a distance to interference sources.
3.
Ensure to apply tape on clean, dry and plain surface.
4.
For the best adhesion, please apply the tape with ambient temperature: 70-100°F.
5.
We recommend to make a chamfer on the machine to install the tape.
6.
Recommend Gap between tape and sensor: 1mm.
< +/- 5
< +/- 5
Magnetic tape
< +/- 1,5
Gap
2,5 mm max.
+/- 3
mm
4
17
4
3.5
25
10
11.2
6
15
Gap (sensor
– tape)