45
45
Feed the workpiece all the way through the blade while maintaining firm pressure on the
9.
workpiece against the table and fence, and keeping hands and fingers out of the blade path
and away from the blade.
Stops the saw immediately after the cut is complete.
10.
OPERATIONAL SAFETY CHECK
IMPORTANT:
Perform these
safety checks at least twice every week to ensure
proper and secure emergency and interlock switch function.
Emergency Stop Switch Check
Connect to power, start the main saw blade and the scoring saw to make the machine run.
1.
Push each emergency stop of machine and check if the saw blade and the scoring saw
2.
completely stop within 7 seconds.
With the emergency stop switch depressed, operate the machine to see if it starts.
3.
If the machine does not start the system is operating normally.
If the machine starts, the emergency stop is not operating properly, immediately stop
operation. Have someone trained in electrical circuits inspect and test the system and
possibly replace the emergency stop switch.
Safety Connection Switch Check
Connect to power to the saw. Open the safety door (i.e. saw blade's guard and service door)
1.
at the back of the machine.
Operate the machine. The machine should not operate.
2.
Close the safety door and operate the machine again. The machine should operate.
3.
If machine works as described, the safety connection switch is normal.
If machine does not work as described, the safety connection switch or wiring has failed
and need immediate repair or replacement.
Brake Check
While the saw blade and the scoring saw are running, push the saw stop switch or the
1.
emergency stop switch.
The saw blade and the scoring saw should completely stop within 7 seconds.
2.
If the brake time exceeds 7 seconds, immediately stop operating the machine and repair the
3.
blade brake system.
Содержание STS-14120DRO
Страница 55: ...51 51...
Страница 56: ...52 52 Load Datum Values Only In ABS Mode A Description...
Страница 57: ...53 53...
Страница 58: ...54 54 B Load Datum...
Страница 59: ...55 55 C Troubleshooting...
Страница 60: ...56 56 Select Counting Direction...
Страница 61: ...57 57...
Страница 62: ...58 58 Set Device Resolution...
Страница 63: ...59 59...
Страница 64: ...60 60 Enable and Disable Specified Parameter...
Страница 65: ...61 61...
Страница 66: ...62 62...
Страница 68: ...64 64 Parameter Setting...
Страница 71: ...67 67 External Dimension Mounting Installation 10...
Страница 73: ...69 69...
Страница 74: ...70 70 B Troubleshooting...
Страница 75: ...71 71...
Страница 115: ...111 111 NOTES...