32
32
TABLE ELEVATION LIMIT SCREW
The table movement is limited by upper and lower limit switch. When the table position reaches
the limit screws on table contact with limit switch, table movement stops.
Table position upper and lower hight limit:
Upper hight limit = 6mm
Lower hight limit = 300mm
If the digital control works prepoerly. When the LED
readout shows the hight limit, but table can still move,
the table elevation limit screw need to be adjusted.
1. UNPLUG OR DISCONNECT PLANER FROM
POWER SOURCE AND LOCK OUT POWER.
2. Use digital control to move the table to the upper
limit and stop the movement when LED shows
6mm.
3. Adjusting the height of screw by wrench. Use the
same way to adjust lower limit screw Figure 19.