26
26
Nozzles obstructed.
Clean nozzles with weak acid
solution, such as white vinegar.
Inspect water system and hoses
for impurities and blockages.
Use clean water.
Leak in water system.
Locate source of leak, replace
seals.
Water pump defective.
Inspect and replace if needed.
Cooling switch defective.
Inspect and replace if needed.
Poor atomization of
water, large droplets or
nozzles streaming water.
Insufficient startup power
provided to air compressor.
Turn fan on first and allow it to
reach full speed, then turn on
Cooling.
Diminished air flow.
Run only fan for a short time,
then turn on Cooling switch.
Clogged air filter.
Clean out air filter.
Nozzles or air hoses obstructed.
Clean nozzles with weak acid
solution, such as white vinegar.
Inspect air system and hoses for
blockages. Use clean water.
Cooling used for extended
periods of time, air compressor
overheats.
Allow to cool, then restart.
Unstable power source, causing
compressor to shut off while fan
and water remain running.
Use stable power source.
*IMPORTANT: Some remedies may require a qualified electrician.