Controller inputs function on a short to ground basis.. Any mechanical button (not a switch) will 

activate the controller after a short press. One end of the button should be connected to the controller 

input, and the other should be grounded  ((-) of 12V). All the above diagrams show this solution.

You can also run the controller with other elements or devices, including motion sensors. Motion 

sensors can be found in two versions: a voltage of 230V voltage and a voltage of 5 or 12V. Do not 

connect the sensor directly to the input of the controller, because, especially in the case of 230V 

sensors, it will cause (at best) incorrect performance of the controller, and at worst the controller can 

be completely damaged.

Before mounting the sensors, set their parameters. The most important is the length of the 

impulse (the time for the sensor to start), which should be set to a minimum and should not exceed 

15 seconds (preferable time about 1-5 seconds — this should be checked before purchase). The 

second parameter which can be set on the sensor is the sensitivity and range of the sensor. This 

parameter should be set experimentally in order to enable a steady connection at the proper time.

In some sensors you can choose between various modes of operation. The  triggering mode should 

be turned off, because in this mode the sensor provides the impulse continuously when someone is 

within its range - and the impulse becomes too long in respect to the  requirements of the controller.

Sensors operating at 230V network require the use of relays to separate the 230V circuit from 

the controller inputs. Low voltage sensors will almost certainly need a special adapter, matching the 

sensor signal to requirements of the controller. The following diagrams and descriptions explain how 

to connect the most common types of sensors. If you need to use a different type of sensor, please 

contact the manufacturer to establish how to connect the sensor.

We recommend that buttons (such as door bell ones) are installed on the top and bottom of the 

stairs, besides motion sensors,. 

Motion sensors with a voltage of 230 V

A typical motion sensor (230V) is 

a standard size module and is con-

nected to the installation box. It has 

regulatory elements (time, sensitivity, 

etc.) and usually three contacts for 

wires. Two are plugged into a 230V 

network, and the third wire is used to 

power the receiver (the lamp) and is 

marked with an appropriate symbol. 

Before installing the sensor, carefully 

read the instructions. 

The relays used to separate 

230V circuit from the controller may 

Motion sensor  for 110-230V - CRN 5491

Some motion sensors have a built-in additional twilight sensor. Depending on the sensitivity 

settings it can be inactive in strong light. Thus, illumination of the stairs does not turn on during the 

day. However, this may cause problems - if it rains, the twilight sensor will lighten the stairs. By ad-

justing the sensitivity, you can try to prevent this. We can recommend our 230V sensor CRN-5491, 

modified to work with our controller:

The next diagram is one of a typical motion sensor (230V) connected to the controller. Relays 

must be used! Relay coil voltage must be set at 230V, because this voltage is supplied from the 

motion sensor. Connect input 1 or 2 and (-) of 12V to the contacts of the relay NO (normally open) 

and CO (common),. We recommend the assembly to be done very carefully. If the connections are 

made erroneously, the controller will be damaged.

Содержание RGB STX-1796

Страница 1: ...n eg at the bottom of the stairs illumina tion lights up step by step from bottom to top During the animation the color of the stairs changes according to the selected program scheme RGB After lighting up the entire staircase the light is stable for a short period and then lighting of the staircase goes from the lower to the upper level sequentially step by step In case when another person steps o...

Страница 2: ...width of 8 modules Output capacity up to 5A Running by shorting the input to ground negative power supply Functions buttons and LED control Description of buttons on the body TOP button starts the animation towards the top BOT button starts the animation towards the bottom CON continuous light PRG button to change RGB programs OPT button for changing options of RGB programs LED LED indicator SET s...

Страница 3: ...Speed adjustable 17 Colour burst with full spectrum colours Speed adjustable 18 Cyan marker 19 Colour plasma lightning Speed adjustable 20 White plasma lightning Speed adjustable 21 Colour strobe Speed adjustable 22 Windswept flame effect 3 independent Speed adjustable 23 Subtle flame effect 3 independent Speed adjustable 24 Rainbow trail Fast cycle of primary colours to create a colourful trailin...

Страница 4: ...the LED lighting is connected should be checked carefully Similarly the animation after the button BOT is pressed should be checked in this case the stairs lighting should take place downwards It is recommended to adjust the sensor response to movements without connecting them to the inputs of the controller The sensor pulse time TIME must first be set to extreme minimum and it should not be chang...

Страница 5: ... and the output 22 to the left handrail running down Points R G and B LED strip should be connected properly to each other ie all the points of R together all the points of G together and all points B together Then just set up collection points should be connected to the respective outputs RGB controller If the staircase is smaller and there is no illuminated handrails for example you can use exit...

Страница 6: ...troller and LED points please include your current flowing in the circuit and select the appropriate type of wiring Plus supply line for 12V LED strips or LED lights should have a much larger cross section than the cables between the controller and the LED strips ATTENTION You cannot connect the AC to 5V plus and minus outputs These con tacts are used for low voltage power sensors Installation mus...

Страница 7: ...age sensors will almost certainly need a special adapter matching the sensor signal to requirements of the controller The following diagrams and descriptions explain how to connect the most common types of sensors If you need to use a different type of sensor please contact the manufacturer to establish how to connect the sensor We recommend that buttons such as door bell ones are installed on the...

Страница 8: ...ion sensors connected to the controller Photo to the left shows our product STP 4811 a set of two relays in a single rail case T 35 This set makes it possible to separate 230 V voltage coming simultaneously from two motion sensors Set of two relays STP 4811 ...

Страница 9: ...ust be set to the minimum position Installation of motion sen sors in order to work properly is extremely difficult The visu alization presented here may be helpful We recommend the sensor to be tilted down so it sees only a portion of the first step The top of the Fresnel lens sho uld be covered with an opaque material The motion sensor mounted on the wall ...

Страница 10: ...ut It is important that the sensor the adapter and the driver have been combined in the right way according to the following pictures and diagrams Miniature motion sensor On the back of the sensor is a connector for connecting wires leading to the controller To facilitate assembly to each sensor is added the connector to soldering wires You should keep the correct order of wires according to the d...

Страница 11: ...ts of adapters with sensors should be mounted in their appropriate place by the side of the first and the last step The controller can handle additional input located on the mezzanine In such a case an additional motion sensor or an additional push button should be placed so as to detect the entrance a person to the staircase mezzanine but so it does not react to people walking up the stairs After...

Страница 12: ...down the stairs that it does not re activate the fading lighting of the stairs The best way is to cover the sensor hemispheres respectively Of course the arrangement of the sensors is also very important usually they are placed on the right side of the stairs looking in the direction of movement right hand traffic Some sensors have an additional adjustable parameter the so called dead time It is t...

Страница 13: ...ing two proximity sensors 5V CRN 5483 to the controller Remote control Controller programs can be set remotely by the transmitter SRF 4884 For the example shown above A button activates the animation upward B button turns on continuous light C button changes the programs and D button changes options for the selected program ...

Страница 14: ...troller will return to normal operation Rotation programs can be enabled by changing the parameters of the controller see the next chapter point Flicker 4 Automatic switching programs RGB Adjusting the controller Setting the parameters should be performed only when strictly necessary after reading the following description carefully For your greater safety changing these parameters is blocked by t...

Страница 15: ...r parameters To set another parameter use of the SET button again Description of parameters Flickering 1 Count of stairs The controller is factory set for 15 steps This can be changed with this parameter The range is from 5 to 23 steps To change the number of steps press and hold the SET button during the first flickering You should release the button after the right number of flicks Eg to set 18 ...

Страница 16: ...utton after the first pulse turns the program 1 Wave the second pulse turns on program 2 Cascade and releasing the button after the third pulse switches permanently to program No 3 Elevator To return to the cycle animation function the button should be let go immediately after the end of the flickering Flickering 5 Lighting of the steps You can set the time of a slow lighting of the steps This giv...

Страница 17: ...ontroller will not respond to further impulses Blockade time is pre set for 2 seconds which corresponds to 2 impulses 1 impulse 1 second Flickering 10 Sensors lock This is an important parameter when installing motion sensors In some cases motion sensors cannot be placed in an ideal direction This happens when a person starts going down the stairs and turns on all the lights as if another person w...

Страница 18: ...ET button during the twelfth flickering and releasing it immediately after the fifth slow impulse A successful reset is confirmed by five pulses of the LED Turn on stairs on permanently To turn the light of the stairs on permanently press a CON button or push button connected to the Input No 4 To turn off the permanent light press again the same push buttons The controller then switches to normal ...

Отзывы: