![Badger Meter RF-OMS Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/badger-meter/rf-oms/rf-oms_installation-and-operation-manual_3760315005.webp)
5
2. Pull the trigger to begin the flow.
3. When the desired amount has been pumped,
release the trigger to stop the flow. Press
to
reset counter display to zero.
Programming the Preset Batch Function when RF
Communications are Unavailable
1. To enter the batch-programming mode, press the
button. The following screen will appear:
QT
.
.
AUTO
-->
:
QT
.
..
AUTO
-->
:
-->-->
:
Auto Mode
2. The meter is now ready to be programmed. Change the
batch size by pressing the
,
and
buttons.
a.
Pressing the 10 button will increase the
batching amount in increments of 10 units.
b.
Pressing the 1 button will increase the batching
amount in increments of 1 unit.
c.
Pressing the 0.1 button will increase the
batching amount in increments of 0.1 units.
QT
.
..
AUTO
-->
3. Pull the trigger to begin the flow. The valve will
automatically lock in place, even though the trigger will
fall back to the closed position. The flow will
automatically shut off when the desired batch size has
been dispensed.
The valve will always lock in the maximum open position.
Note: At any time during the operation of the meter, the
flow may be stopped by pressing the red
button.
This will electronically close the valve, stopping the flow.
Batching may be resumed by pulling the trigger.
4. The user has the option to top off at the end of the batch.
To top off the tank, simply pull the trigger to begin the flow
and release when the desired amount has been
pumped.
5. Press the
button when finished to reset the
meter. It is now ready for the next batch.
Do
NOT
press
before topping off. The meter will
begin a new batch.
Normal Operating Mode Functions
Total
This option allows users to see the accumulated total as
well as the resettable total.
Press and hold the
button while in normal
operating mode to see the accumulated total. Continue
holding and after three seconds the screen will change to
the resettable total, which displays the total fluid
dispensed since the resettable total was last set back to
zero.
Press the
button while viewing the resettable total
to set the resettable total back to zero. Release the
button to return to the normal operating screen.
Note: The accumulated total cannot be reset, unless the
user changes from English units to metric units or from
metric to English units. (See Changing Factory Settings.)
L
RESET TOTAL
Total Function
Electrical Override
In case of an emergency or to interrupt a batch, the meter
is equipped with an
electrical override
. This option
automatically closes the valve in the meter, stopping the
flow immediately. Batching can be continued after an
override, even if the meter is in the middle of a
programmed batch.
Press the red
button to activate the electrical
override. This can only be used when the valve is open.
Service
Changing the Battery
When the batteries need to be changed, a progression of
warnings will appear on the screen.
1. First warning: the
Low Battery Icon
will appear in the
lower left corner of the display. This means that the
batteries are low and need to be changed within one
week after the icon first appeared.
QT
.
-
+
QT
.
QT
..
-
+
-
+
+