General Information

2

Scope of this manual

This manual contains information concerning the installation,
operation and maintenance of the Badger

®

 RET™ Recordall

®

Electronic Transmitter.  To  ensure proper performance, the
instructions given in this manual should be thoroughly under-
stood. Retain the manual in a readily accessible location for
future reference.

Installation, operation and wiring of this unit is fairly simple
and straight forward. This manual is designed so as to provide
you with a step by step guide for this purpose.

Programming the unit is covered later in this manual and
requires a personal computer, a programming interface unit

and special software.  The latter two can be purchased from
Badger Meter if required.

The  examples provided are only to facilitate an understand-
ing of the functions of the product. Your specific application
will most likely have a different set of values.

The troubleshooting section attempts to illustrate the most
common problems that can be encountered, their most likely
cause and the recommended solution. If a problem persists,
please contact our technical support group at:

Badger Meter, Inc. Customer Service

1-800-876-3837

Specifications

The Recordall

®

 Electronic Transmitter (RET

) is designed

for use with all Recordall Disc, Compound and Turbo Series
meters  as well as Turbo II meters to provide output compat-
ibility with standard industry instrumentation devices.

The RET is equipped with an  LCD digital display that can
be calibrated in either gallons, cubic feet, cubic meters, liters
or imperial gallons. Using a magnet the product allows the
user to toggle between the different displays of totalization,
flow rate, reverse flow, and other meter specific information.

The Recordall Electronic Transmitter is offered in two prod-
uct versions.  The standard RET unit comes complete with

both a scaled open collector and unscaled open collector
output signal.  The product  is also offered with an optional
4 to 20 mA output providing a rate of flow signal.

The Recordall Electronic Transmitter is field programmable
allowing the unit to be calibrated remotely and interchanged
with other Badger Meter products.   An internal lithium bat-
tery is used to power the display .  The 4 to 20 mA option
requires additional external power for operation.

The RET is designed to be totally submersible.  Connec-
tion is made via a waterproof connector cable available in
various lengths.

Transmitter/Register

Liquid  crystall display, permanently sealed, magnetic pick-ups, multiple outputs, water proof connection

Liquid Crystal Display

Six  digits with  1/4" numerals

Weight

13 Ounces

Humidity

0% to 100% Condensing

Operating Temperature

-10  to 60°C (14  to 140°F)

Unit of Measure

U.S. Gallons, Cubic Feet, Cubic Meters, Liters, Imperial Gallons clearly identified on LCD display

Rate of Flow

Units per Minute or Units per Hour

Rate of Flow Response

6 seconds when flow rate is 10% to 100% of maximum flow.  Response time is programmable when flow
rates are < 10% of maximum flow.

Test Mode Totalization

1/1000th of totalization display

Backflow Totalization

1/1000th of totalization display

Internal Power Source

One lithium, 2.4 A hr. battery

External Power

9.0V 0- 50VDC ( required to use optional 4-20 mA output) max loop resistance = 50 Ohms + 50 Ohms
(Vsupply - 9V)

Electrical Criteria

Immunity to electrical surges and transient per IEC 1000-4-2 & IEC 1000-4-4.

FCC Compliance

FCC Part 15 Subpart J

Signal Characteristics

Open Drain (FET)

Resolution

Scaled is programmable with unscaled  fixed for the individual meter

On State Resistance

<50 Ohms @ 25°C (77°F) for scaled output, <400 Ohm @ .1mA for unscaled output

Off State Resistance

>5 MOhms @ 25°C (77°F)

Power Source

Internal with External Option

Maximum Switching

30 VDC @ 1 mA @ 25°C (77°F)

This Product Contains Lithium Batteries.

Read This Manual Before Attempting Any Installation,

Wiring or Operation.

Содержание Recordall RET

Страница 1: ...BadgerMeter Inc Installation Operation Manual Model RET Recordall Electronic Transmitter Providing Unscaled Scaled Optional 4 20 mA Outputs RET IOM 1 P N59322 033 2 02...

Страница 2: ...complete with both a scaled open collector and unscaled open collector output signal The product is also offered with an optional 4 to 20 mA output providing a rate of flow signal The Recordall Elect...

Страница 3: ...with the short alignment mark up and position the band so that the long alignment mark is lined up with the alignment mark at the base of the female connector 2 Insert the male connector into the fem...

Страница 4: ...LITER will be shown with the corresponding time unit per MIN per HOUR The flow rate resolution will vary with meter size There are no multipliers used for flow rate Flow in the re verse direction is d...

Страница 5: ...ic interface circuit used to program and read the parameters of the Recordall Electronic Transmitter RET The RET Programmer is powered by a stan dard 9 volt alkaline battery Connection from the RET Pr...

Страница 6: ...ove the pointer to the desired box Click the left mouse button to place the cursor in the box Use the backspace key to erase the existing number and use the keyboard to input a new number After the pa...

Страница 7: ...d range the user will be notified when the operator attempts to program the RET The message will be The Set Point value entered was not within limits of 50 to 120 Numeric Limits are ____ to ____ and t...

Страница 8: ...ring 2 Check connections Troubleshooting Ctrl Alt Delete keys simultaneously and shut off the appropriate applications The computer screens of the RET Programmer can be printed to provide a copy of th...

Страница 9: ...0 0 6509 310 0000 3 0733 TSM 200 200 ft3 10 1 0 1 1 0 0871 41 4408 22 9999 TSM 200 200 m3 1 0 01 0 01 0 1 0 0026 1 1737 812 7840 TSM 200 200 IMP 100 10 1 10 0 542 258 1463 3 6906 TSM 200 200 liter 100...

Страница 10: ...47 104712 4000 CSM 3 H C400H IMP 100 10 1 10 0 6246 375 0000 3 8440 CSM 3 L C400L IMP 10 1 0 1 1 0 0348 20 8183 476 2456 CSM 3 H C400H liter 100 100 1 10 2 84 1700 0000 0 8440 CSM 3 L C400L liter 10 1...

Страница 11: ...4 64 4396 8144 0 0812 turbo II 10 II 10 liter 1000 100 1 100 100 19990 6080 0 0179 turbo II 12 II 12 gal 10000 100 1 1000 37 38 6600 0000 0 0535 turbo II 12 II 12 ft3 1000 10 1 100 4 997 882 2880 0 40...

Страница 12: ...ng bid obligation exists Copyright BadgerMeter Inc 2002 Allrightsreserved alldatasubjecttochangewithoutnotice Please see our website at www badgermeter com for specific contacts BadgerMeter Inc P O Bo...

Отзывы: