background image

Badger Meter Warranty

Badger Meter Warranty

PFA Ellipse

Fire Pump System

10-PTT-UM-00311  08/12

PRODUCTS COVERED

The Badger Meter warranty shall apply to the Preso PFA Ellipse Fire 
Pump System  (“Product”). 

MATERIALS AND WORKMANSHIP

Badger Meter warrants the Product to be free from defects in 

materials and workmanship for a period of 12 months from the 

original purchase date. 

PRODUCT RETURNS 

Product failures must be proven and verified to the satisfaction 

of Badger Meter. The Badger Meter obligation hereunder shall be 

limited to such repair and replacement and shall be conditioned 

upon Badger Meter receiving written notice of any asserted defect 

within 10 (ten) days after its discovery. If the defect arises and a valid 

claim is received within the Warranty Period, at its option, Badger 

Meter will either (1) exchange the Product with a new, used or 

refurbished Product that is at least functionally equivalent to the 

original Product, or (2) refund the purchase price of the Product. DO 

NOT RETURN ANY PRODUCT UNTIL YOU HAVE CALLED THE BADGER 

METER CUSTOMER SERVICE DEPARTMENT AND OBTAINED A RETURN 

AUTHORIZATION.

Product returns must be shipped by the Customer prepaid F.O.B. 

to the nearest Badger Meter factory or distribution center. The 

Customer shall be responsible for all direct and indirect costs 

associated with removing the original Product and reinstalling the 

repaired or replacement Product. A replacement Product assumes 

the remaining warranty of the original Product or ninety (90) 

days from the date of replacement, whichever provides longer 

coverage. 

LIMITS OF LIABILITY

This warranty shall not apply to any Product repaired or altered 

by any Product other than Badger Meter. The foregoing warranty 

applies only to the extent that the Product is installed, serviced and 

operated strictly in accordance with Badger Meter instructions. The 

warranty shall not apply and shall be void with respect to a Product 

exposed to conditions other than those detailed in applicable 

technical literature and Installation and Operation Manuals (IOMs) 

or which have been subject to vandalism, negligence, accident, acts 

of God, improper installation, operation or repair, alteration, or other 

circumstances which are beyond the reasonable control of Badger 

Meter. 

With respect to products not manufactured by Badger Meter, the 

warranty obligations of Badger Meter shall in all respects conform 

and be limited to the warranty extended to Badger Meter by the 

supplier. 

THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF 

ALL OTHER EXPRESS AND IMPLIED WARRANTIES WHATSOEVER, 

INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF 

MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE 

(except warranties of title). 

Any description of a Product, whether in writing or made orally by 

Badger Meter or its agents, specifications, samples, models, bulletins, 

drawings, diagrams, engineering sheets or similar materials used in 

connection with any Customer’s order are for the sole purpose of 

identifying the Product and shall not be construed as an express 

warranty. Any suggestions by Badger Meter or its agents regarding 

use, application or suitability of the Product shall not be construed 

as an express warranty unless confirmed to be such, in writing, by 

Badger Meter. 

EXCLUSION OF CONSEQUENTIAL DAMAGES AND 

DISCLAIMER OF OTHER LIABILITY

Badger Meter liability with respect to breaches of the foregoing 

warranty shall be limited as stated herein. Badger Meter liability 

shall in no event exceed the contract price. BADGER METER SHALL 

NOT BE SUBJECT TO AND DISCLAIMS: (1) ANY OTHER OBLIGATIONS 

OR LIABILITIES ARISING OUT OF BREACH OF CONTRACT OR OF 

WARRANTY, (2) ANY OBLIGATIONS WHATSOEVER ARISING FROM 

TORT CLAIMS (INCLUDING NEGLIGENCE AND STRICT LIABILITY) 

OR ARISING UNDER OTHER THEORIES OF LAW WITH RESPECT TO 

PRODUCTS SOLD OR SERVICES RENDERED BY BADGER METER, OR 

ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATING THERETO, AND 

(3) ALL CONSEQUENTIAL, INCIDENTAL AND CONTINGENT DAMAGES 

WHATSOEVER.

Содержание PRESO Ellipse PFA Series

Страница 1: ...anual 10 PTT UM 00311 August 2012 PFA Ellipse Fire Pump System Badger Meter FLOW METERS DEBITMETERS MEDIDOR DE FLUJO F M APP RO VE D F M APPROVED PFA XXX X inch 250 SWP X XX S N AXXXXXXX 1000 1500 2000 2500 GPM 3000 3500 4000 ...

Страница 2: ... comes with instru ment shut off valves with provisions to accept a direct indicating meter II SPECIFICATIONS Applications Liquids Pipe Sizes 2 to 16 inches 50 to 406 4 mm Pressure 400 PSI 2758 kPa maximum Temperature Gage PFA Velocity Sensor 180 F 80 C maximum 250 F 121 C maximum Accuracy 1 75 of reading Turndown Ratio 17 1 with no vacuum effect Standard Components Y type head brass Compression f...

Страница 3: ...F M APPROVED FIGURE 1 HORIZONTAL PIPE INSTALLATION LIQUID F L O W M E T E R S D E B IT M E T E R S M E D ID O R D E F L U J O F M A P P R O V ED F L O W FIELD WELD H L FLOW METERS DEBIT METERS MEDID OR DE FLUJO F M APPROVED F L O W FIELD WELD H L FIGURE 2 VERTICAL PIPE INSTALLATION NOTE Pipe must remain full at all times during measurements NOTE Pipe must remain full at all times during measuremen...

Страница 4: ... 6 12 PFA 1 11 14 16 PFA 1 1 13 TABLE 1 SINGLE SUPPORT DRILL BIT SIZE 6 Install the supplied compression fitting by threading it into the weld o let manually Then with a wrench tighten the fitting a further 1 turns taking care not to tighten the compression nut 7 Install the instrument valves at the PFA Ellipse head connections Ensure that the valves are FULLY CLOSED to prevent them from leaking d...

Страница 5: ...A Ellipse sensor through the two holes Make sure that the double support pin passes through the guide ring See Figure 5 4 Align the arrow located on the sensor head in the direction of flow as in Step 9 Section IV 5 Ensure that the PFA Ellipse is in the correct orientation and spans the inside of the pipe Tighten the compression nut After tightening the compression nut manually tighten it 1 turns ...

Страница 6: ...FLUJO F M APP RO VE D FLOW FIELD WELD H L H L FIGURE 4 SENSOR ALIGNMENT PIPE SIZE MODEL SENSOR WELD CONNECTOR DRILL BIT 2 5 PFA 1 3 6 12 PFA 14 16 PFA 1 1 TABLE 2 DOUBLE SUPPORT DRILL BIT SIZE Ellipse Sensor Double Support Pin Guide Ring FIGURE 5 DOUBLE SUPPORT PIN ...

Страница 7: ...Ellipse in a level position See Figure 6 NOTE If recommended mounting is not possible care must be taken to ensure that the gage is vented periodically FLOW METERS DEBITMETERS MEDIDOR DE FLUJO F M APPROVED F M APPROVED PFA XXX X inch 250 SWP X XX S N AXXXXXXX 1000 1500 2000 2500 GPM 3000 3500 4000 VENT VALVES FLOW BY PASS VALVE H L FIGURE 6 RECOMMENDED INSTALLATION ...

Страница 8: ...E RS DEBI TMET ERS MEDI DOR DE FLUJ O FLOW METE RS DEBI TMET ERS MEDI DOR DE FLUJ O F M APPROVED F M APPROVED PRESO FIRE PUMP SYSTEM F M APPROVED PFA XXX X inch 250 SWP X XX S N AXXXXXXX 1000 1500 2000 2500 GPM 3000 3500 4000 7 3 Flow Flow Pipe Diameters From Valve PRESO PFA Valve Throttle Valve Throttle Valve System By pass Valve Supply Discharge Optional to Pump Inlet Air Vent Fire Pump PRESO PR...

Страница 9: ...run from the gage vent valves to a pan or drain VIII GAGE OPERATION 1 Identify Hi and Lo pressure inlets on the gage 2 Ensure by pass valve blue is OPEN WARNING WARNING Gage may be damaged if initially pressurized with the by pass valve closed 3 Connect gage to corresponding Hi and Lo pressure taps of the PFA Ellipse via 3 valve manifold if being used 4 Open Hi and Lo instrument valves on the PFA ...

Страница 10: ...Page 10 10 PTT UM 00311 08 12 ...

Страница 11: ... and shall be void with respect to a Product exposed to conditions other than those detailed in applicable technical literature and Installation and Operation Manuals IOMs or which have been subject to vandalism negligence accident acts of God improper installation operation or repair alteration or other circumstances which are beyond the reasonable control of Badger Meter With respect to products...

Страница 12: ... 800 876 3837 414 355 0400 México Badger Meter de las Americas S A de C V Pedro Luis Ogazón N 32 Esq Angelina N 24 Colonia Guadalupe Inn CP 01050 México DF México 52 55 5662 0882 Europe Middle East and Africa Badger Meter Europa GmbH Nurtinger Str 76 72639 Neuffen Germany 49 7025 9208 0 Czech Republic Badger Meter Czech Republic s r o Maříkova 2082 26 621 00 Brno Czech Republic 420 5 41420411 Slov...

Отзывы: