Programming of LM OG-AM and LM OG-TAERM series 

Page 6

 

LM_OG-AM_BA_02_1163

 

May 2019 

6.

 

PROGRAMMING OF LM OG-AM AND LM OG-TAERM SERIES 

The units of measure and the correction factor can be configured in the programming mode. A program button on the 

backside of the register will enable the mode, only accessible when the register has been removed from the meter. Removing 

the register from the meter will break the sealing. This seal has to be restamped by the national authorities (MID). 

 

01 

Turn on the register by pressing the 

TOTAL button. 

   

07 

The fifth number can now be changed.  

To move forward, press “TOTAL” again. 

 

02 

By pressing the programming button on 

the backside of the register you will enter 

the programming mode. 

   

08 

The arrow for the flow direction flashes 

now. Use RESET to change or TOTAL to 

move forward. 

 

03 

The measuring unit will flash and can be 

changed by pressing the RESET button (L, 
GAL, QT, PT). 

To move forward press the TOTAL button. 

   

09 

By pressing the programming button on 

the backside of the register you will quit 
the programming mode. 

 

03 

Press “TOTAL” to change the k-factor. The 

number to be changed is flashing and can 

be modified with “RESET”. 

To change the next number, press 

“TOTAL”. 

   

10 

The register went into the sleep mode. 

 

04 

The second number can now be changed.  

To move to the next number, press 

“TOTAL” again. 

   

11 

To wake up the register, press the RESET 

button. 

 

05 

The third number can now be changed.  

To move to the next number, press 

“TOTAL” again. 

   

12 

Press „RESET“ for 3 seconds and the 

register displays the checksum and serial 

number in the bottom line. 

 

06 

The fourth number can now be changed.  

To move to the next number, press 
“TOTAL” again. 

   

 

 

 

Содержание Oval Gear LM OG-AM

Страница 1: ...LM OG AM series Oval gear meters with MID approved register and integrated datalogger LM_OG AM_BA_02_1163 May 2019 User Manual LM OG AM LM OG TAERM LM OG CNDAM...

Страница 2: ...conform meters 5 5 8 Installation procedure LM OG 5 6 Programming of LM OG AM and LM OG TAERM series 6 7 Calculating the correction factor 7 7 1 Calculation based default settings 7 7 2 Recalculation...

Страница 3: ...table surface that may allow it to fall Never place the units above a radiator or heating unit Route all cabling away from potential hazards Isolate from the mains before removing any covers Power con...

Страница 4: ...ation match with those of the lube meter for example connections pressure flow range and medium Once the meter has been installed please make sure that no air pressure shocks or particles can damage t...

Страница 5: ...technicians or the officials of the national authorities MID 4 WARRANTY Badger Meter warrants meters and parts manufactured by it and supplied hereunder to be free from defects in materials and workma...

Страница 6: ...front of the register No data are lost they are securely saved in an EEPROM memory except of the date and time To keep the date and time settings you have to reinsert the battery within 30 minutes See...

Страница 7: ...dispense system or by an insufficiently areated oil pipe pressure shocks This can be prevented by installing an appropriate non return valve FLDIR will indicate a reverse flow quantity display will ch...

Страница 8: ...arrow for the flow direction flashes now Use RESET to change or TOTAL to move forward 03 The measuring unit will flash and can be changed by pressing the RESET button L GAL QT PT To move forward pres...

Страница 9: ...ctor would be for example 0 9960 Calculation 0 9960 x 1 003 0 9989 The new correction factor is 0 9989 8 PULSE OUTPUT AT REGISTER OG TAERM The pulse output on the LM OG TAERM register has a rating of...

Страница 10: ...or more than 2s will bring you to the next lower menu level Pressing the TOTAL button once will bring you to the next newer data entry no matter if you are on the Date Time or Quantity menu level If y...

Страница 11: ...e register will automatically move back to the standard display without saving the last entry 10 DISPLAY CORRECTION FACTOR To verify the programmed correction factor press TOTAL and RESET for 2 second...

Страница 12: ...wake up the register Picture 4 Insert the battery cover then screw the battery cover tight Battery Lithium CR123A 3A33 07 L AC001 TOTAL 3A33 Checksum over the MID relevant source code 07 Sequential ve...

Страница 13: ...ll CE declarations applying to this meter series under www badgermeter de en downloads ce declarations 16 DIN ISO AND EMC CERTIFICATE Please refer to our valid DIN ISO and EMC certificate under www ba...

Страница 14: ...Return of goods for repair Harmlessness declaration Page 12 LM_OG AM_BA_02_1163 May 2019...

Страница 15: ...Return of goods for repair Harmlessness declaration May 2019 LM_OG AM_BA_02_1163 Page 13...

Страница 16: ...www badgermeter de...

Отзывы: