DISCLAIMER 

The user/purchaser is expected to read and understand the information provided in this manual, follow any listed safety 

precautions and instructions and keep this manual with the equipment for future reference. The information in this manual 

has been carefully checked and is believed to be entirely reliable and consistent with the product described. However, no 

responsibility is assumed for inaccuracies, nor does Badger Meter assume any liability arising out of the application and use of 

the equipment described. Should the equipment be used in a manner not specified by Badger Meter, the protection provided 

by the equipment may be impaired and the warranty voided. The meter is conform to the MID regulations for liquids other 

than water. 

 

 

2.

 

BASIC SAFETY RECOMMENDATIONS 

Before installing or using this product, please read this instruction manual thoroughly. Only qualified personnel should install 

and/or repair this product. If a fault appears, contact your distributor. 

 

Installation 

Do not place any unit on an unstable surface that may allow it to fall. 

Never place the units above a radiator or heating unit. 

Route all cabling away from potential hazards. 

Isolate from the mains before removing any covers. 

 

Power connection 

Use only the type of power source suitable for electronic equipment.  If in doubt, contact your distributor. Ensure that any 

power cables are of a sufficiently high current rating. All units must be earthed to eliminate risk of electric shock. Failure to 

properly earth a unit may cause damage to that unit or data stored within it. 

 

Protection class 

Following devices have protection class IP65: 

LM OG-AM 

Standard inline meter 

LM OG-KAM 

Coated standard inline meter 

LM OG-CDAM 

Pistol meter with handle, sightglas and swivel 

LM OG-CNDAM 

Pistol meter with handle, sightglas, swivel and outlet 

LM OG-TAERM 

Inline meter with pulse output 

LM OG-TAERKM 

Coated inline meter with pulse output 

 

All devices have to be protected against dripping water, water, oils, etc. 

 

Setup & operation 

Adjust only those controls that are covered by the operating instructions.  Improper adjustment of other controls may result 

in damage, incorrect operation or loss of data. 

 

Cleaning 

Switch off all units and isolate from mains before cleaning. 

Clean using a damp cloth.  Do not use liquid or aerosol cleaners. 

 

 

Содержание Oval Gear LM OG-AM

Страница 1: ...LM OG AM series Oval gear meters with MID approved register and integrated datalogger LM_OG AM_BA_02_1163 May 2019 User Manual LM OG AM LM OG TAERM LM OG CNDAM...

Страница 2: ...conform meters 5 5 8 Installation procedure LM OG 5 6 Programming of LM OG AM and LM OG TAERM series 6 7 Calculating the correction factor 7 7 1 Calculation based default settings 7 7 2 Recalculation...

Страница 3: ...table surface that may allow it to fall Never place the units above a radiator or heating unit Route all cabling away from potential hazards Isolate from the mains before removing any covers Power con...

Страница 4: ...ation match with those of the lube meter for example connections pressure flow range and medium Once the meter has been installed please make sure that no air pressure shocks or particles can damage t...

Страница 5: ...technicians or the officials of the national authorities MID 4 WARRANTY Badger Meter warrants meters and parts manufactured by it and supplied hereunder to be free from defects in materials and workma...

Страница 6: ...front of the register No data are lost they are securely saved in an EEPROM memory except of the date and time To keep the date and time settings you have to reinsert the battery within 30 minutes See...

Страница 7: ...dispense system or by an insufficiently areated oil pipe pressure shocks This can be prevented by installing an appropriate non return valve FLDIR will indicate a reverse flow quantity display will ch...

Страница 8: ...arrow for the flow direction flashes now Use RESET to change or TOTAL to move forward 03 The measuring unit will flash and can be changed by pressing the RESET button L GAL QT PT To move forward pres...

Страница 9: ...ctor would be for example 0 9960 Calculation 0 9960 x 1 003 0 9989 The new correction factor is 0 9989 8 PULSE OUTPUT AT REGISTER OG TAERM The pulse output on the LM OG TAERM register has a rating of...

Страница 10: ...or more than 2s will bring you to the next lower menu level Pressing the TOTAL button once will bring you to the next newer data entry no matter if you are on the Date Time or Quantity menu level If y...

Страница 11: ...e register will automatically move back to the standard display without saving the last entry 10 DISPLAY CORRECTION FACTOR To verify the programmed correction factor press TOTAL and RESET for 2 second...

Страница 12: ...wake up the register Picture 4 Insert the battery cover then screw the battery cover tight Battery Lithium CR123A 3A33 07 L AC001 TOTAL 3A33 Checksum over the MID relevant source code 07 Sequential ve...

Страница 13: ...ll CE declarations applying to this meter series under www badgermeter de en downloads ce declarations 16 DIN ISO AND EMC CERTIFICATE Please refer to our valid DIN ISO and EMC certificate under www ba...

Страница 14: ...Return of goods for repair Harmlessness declaration Page 12 LM_OG AM_BA_02_1163 May 2019...

Страница 15: ...Return of goods for repair Harmlessness declaration May 2019 LM_OG AM_BA_02_1163 Page 13...

Страница 16: ...www badgermeter de...

Отзывы: