background image

ORION® and GALAXY®

Gateway Configuration Software

ORI-AS-00036-EN-06 (April 2015)

Application Data

GALAXY TR3 Gateway Receiver

ORION Fixed Network (SE) Gateway Transceiver

Содержание ORION Fixed Network SE

Страница 1: ...ORION and GALAXY Gateway Configuration Software ORI AS 00036 EN 06 April 2015 Application Data GALAXY TR3 Gateway Receiver ORION Fixed Network SE Gateway Transceiver ...

Страница 2: ...ORI AS 00036 EN 06 ORION and GALAXY Gateway Configuration Software Page ii April 2015 ...

Страница 3: ...TWARE 13 Launching the Software 13 Exiting the Software 13 Gateway Information 14 ORION SE Gateway Information Screen 14 GALAXY Gateway Information Screen 16 Gateway Network Configuration 17 CDMA Configuration Screen 17 GPRS Configuration Screen 19 LAN Configuration Screen 21 WiFi Configuration Screen 23 GATEWAY IDENTIFICATION ORION SE 25 Set the Utility Passkey 25 UPDATING THE GATEWAY FIRMWARE 26...

Страница 4: ...ORI AS 00036 EN 06 ORION and GALAXY Gateway Configuration Software Page iv April 2015 ...

Страница 5: ...ers to both ORION SE and SE II gateways and GALAXY gateway refers to the GALAXY TR3 gateway Proper performance and reliability of the gateway depends upon the proper software settings as described in this document NOTE N To provide the best solution for our customers Badger Meter continually improves software programs and updates the technical literature to reflect upgrades Therefore some discrepa...

Страница 6: ...way Result The AutoPlay window opens automatically Figure 1 Software AutoPlay window 2 Click Open folder to view files 3 When the folder opens double click setup exe Figure 2 Double click setup exe Result The software wizard Welcome screen opens as shown in Figure 3 Figure 3 Installation Wizard Installing the Software Page 6 April 2015 ...

Страница 7: ...zation fields Figure 4 Customer information 6 Click Next Result The Destination Folder is displayed as shown in Figure 5 Figure 5 Software destination folder 7 Click Next NOTE N If you prefer a different location click the Change button to make another selection then click Next Installing the Software Page 7 April 2015 ...

Страница 8: ...een opens Figure 6 Ready to install software 8 Confirm the Settings and click Install Figure 7 Progress bar displays Result A progress bar displays while the software is installing Then the Wizard Completed screen appears Installing the Software Page 8 April 2015 ...

Страница 9: ...uter desktop Figure 9 Desktop shortcut IMPORTAN I Do not launch the configuration software until the gateway is installed 10 Remove the software DVD from the computer Before using the configuration software connect the computer to the gateway using the programming harness See Connecting to the Gateway on page 10 for instructions Installing the Software Page 9 April 2015 ...

Страница 10: ...s PN 66529 002 5 pin power cable connector PN 66233 010 013 5 pin programming harness PN 66529 001 Figure 10 Power cable and programming harness connectors NOTE N ORION SE gateways use the 7 pin serial programming harness Inserting the Programming Harness DISCONNECT THE POWER SUPPLY TO THE GATEWAY WHILE YOU INSERT THE SERIAL PROGRAMMING HARNESS THEN RECONNECT THE POWER SUPPLY AFTER THE PROGRAMMING...

Страница 11: ...l port connection of the programming harness to the serial port on the computer with the configuration software If the computer does not have a serial port use a USB to serial port adapter 3 Reconnect the power supply to the gateway 4 Click the computer desktop icon to launch the configuration software See Figure 9 on page 9 Result The Connection Settings window opens Connecting to the Gateway Pag...

Страница 12: ...rogramming harness In Figure 14 COM 5 is the port for the programming harness connected to the computer via a USB serial adapter Figure 14 COM ports shown in Device Manager Close the Device Manager screen when you are finished In the Connection Settings window use the Port drop down menu to select the COM port you identified on the Device Manager screen The Baud should be 9600 as shown in the Baud...

Страница 13: ...ou use the configuration software Launching the Software NOTE N Make sure the computer with the installed software is connected to the gateway before launching the software See Connecting to the Gateway on page 10 if you need help Click the Gateway Configure software desktop shortcut icon to launch the software application Figure 15 Desktop shortcut Exiting the Software When the gateway configurat...

Страница 14: ... serial number assigned to the gateway The serial number is shown on a label on the side of the gateway transceiver enclosure AMR Network Identifies the gateway technology Backhaul Network Refers to the communication method between the gateway and the reading data management software Options are CDMA GPRS LAN or WiFi Backhaul RSSI Good Average Poor or Not Applicable Refers to the signal strength o...

Страница 15: ... the Connection Int s field Last TCP Attempt The last attempt to establish a connection to the reading data management system after the beacon is received Backhaul State The current state of the backhaul One of the following descriptions displays Shutdown Reset Identify Initialize Attach Active UDP Socket Create TCP Socket Active TCP Socket Detach Set Device Parameters Other Temperature The temper...

Страница 16: ...dicates the gateway hears any endpoints in range Positive indicates the gateway hears assigned endpoints only Firmware Version Firmware version of the gateway Endpoint Count The number of endpoints assigned to the gateway Repeater Count n a RSSIz Reflects the backhaul signal strength The value changes based on backhaul cellular communication RSSIy n a RSSIx n a KA Sent Count The number of Keep Ali...

Страница 17: ...en shown in Figure 18 is an example of the CDMA Configuration screen filled with sample data Figure 18 CDMA configuration screen Changing Configuration Settings The CDMA Configuration screen is divided into three sections Destination Settings Gateway IP Settings Backhaul Identification Fields in the Destination Settings and Gateway IP Settings sections are programmable If you make a change the Sav...

Страница 18: ...system The setting depends on the firmware version Keep Alive Int m Customer supplied setting which defines how often the gateway sends a message to the reading data management system to stay connected The default setting is 9 minutes Read only field Setting which defines how often the gateway sends a message to the reading data management system to stay connected The setting is 9 minutes Gateway ...

Страница 19: ...ttings The GPRS Configuration screen is divided into four sections Destination Settings Gateway IP Settings GPRS Settings Backhaul Identification Fields in the Destination Gateway IP and GPRS Settings sections are programmable If you make a change the Save button becomes available Click Save to save any changes in the section Click Reload to restore the current configuration settings NOTE N Reload...

Страница 20: ...a message to the reading data management system to stay connected The default setting is 9 minutes Read only field for GALAXY Defines how often the gateway sends a message to the reading data management system to stay connected Gateway IP Settings Field Description for ORION SE and GALAXY Gateways DHCP Enabled Field automatically fills with information from the network Applicable for LAN only IP A...

Страница 21: ...Configuration screen is divided into three sections Destination Settings Gateway IP Settings Backhaul Identification Fields in the Destination and Gateway IP Settings sections are programmable If you make a change the Save button becomes available Click Save to save any changes in the section Click Reload to restore the current configuration settings NOTE N Reload can only restore current configur...

Страница 22: ...es how often the gateway sends a message to the reading data management system to stay connected The default setting is 9 minutes Read only field for GALAXY Defines how often the gateway sends a message to the reading data management system to stay connected Gateway IP Settings Field Description for ORION SE and GALAXY Gateways DHCP Enabled Field automatically fills with information from the netwo...

Страница 23: ...nfiguration screen is divided into four sections Destination Settings Gateway IP Settings WiFi Settings Backhaul Identification Fields in the Destination Gateway IP and WiFi Settings sections are programmable If you make a change the Save button becomes available Click Save to save any changes in the section Click Reload to restore the current configuration settings NOTE N Reload can only restore ...

Страница 24: ...eway DHCP Enabled Field automatically fills with information from the network Remove the check mark in the box to change the settings in this section IP Address Customer supplied Can be changed based on the network settings Subnet Mask Customer supplied Can be changed based on the network settings Gateway Address Customer supplied Can be changed based on the network settings WiFi Settings Field De...

Страница 25: ...ted code 8 32 characters used for gateway protection Passkey Strength Indicates the protective strength of the passkey A strong passkey is recommended Confirm Passkey The encrypted code is repeated in this field to confirm the correct passkey for the gateway Set the Utility Passkey 1 Key the passkey in the New Utility Passkey field The strength of the passkey will display in the Passkey Strength f...

Страница 26: ...pdate Result The Gateway Firmware Update screen displays as shown in Figure 23 Figure 23 Gateway firmware version update 4 In the Update File field browse and select the Gateway Firmware Update file Result The Start Update button becomes active when the file is selected 5 Click Start Update Result A warning message displays 6 Click Yes to continue the firmware update process NOTE N If you click No...

Страница 27: ...the confirmation message exit and reopen the software See Using the Software on page 13 if you need help Then continue to step 8 8 Access the gateway information screen to verify the firmware version is updated in the Firmware Version field 9 Exit the software disconnect the programming harness from the computer and reconnect the gateway power The firmware update is complete Updating the Gateway F...

Страница 28: ...xico Badger Meter de las Americas S A de C V Pedro Luis Ogazón N 32 Esq Angelina N 24 Colonia Guadalupe Inn CP 01050 México DF México 52 55 5662 0882 Europe Middle East and Africa Badger Meter Europa GmbH Nurtinger Str 76 72639 Neuffen Germany 49 7025 9208 0 Europe Middle East Branch Office Badger Meter Europe PO Box 341442 Dubai Silicon Oasis Head Quarter Building Wing C Office C209 Dubai UAE 971...

Отзывы: