5.2.6 Advanced
Configuration
Token properties
•
Write protection (ON/OFF)
•
Power on load (ON/OFF)
•
On time load (ON/OFF)
Parameter Selection
•
Group 0 (ALL)
•
Group 1 (User)
•
Group 2 (PRV)
•
Group 3 (FACT)
•
Group 4 (PORT A)
•
Group 5 (PORT B)
•
Group 0 (SECURATY)
Store to
Token
Store the selected device datas at the memory token.
Restore from
Token
Restoring data from the memory token to the device.
Encoder protocol
•
Disabled
•
V1
•
V2
Absolute Digital Encoder (ADE
®
). Remote meter reading technology
using ASCII communications protocols.
Totalizer Dial
4-dial up to 10-dial
Select the number of digits that the totalizer should display.
For example 6-dial will be displayed with 6 total digits like
12.3456 m³/h.
Note: A totalizer roll over can be indicated by a totalizer alarm via the
digital output (see Digital Output / Functional selection)
See also Totalizer Resolution.