Badger Meter HR-LCD Pulse Скачать руководство пользователя страница 10

Using the Programmer Software 

Change Current Settings

To change the register settings and set a new default value for any of the data fields, follow this procedure .
1 .  Click the drop-down menu to the right of the field to display a list of values .
2 .  Click the value you want to set as the default for that field . 

OTEE:

N

The field label changes to bold text, indicating a new, unprogrammed value is selected . See 

Figure 13

.

 

You must set the default value for the 

Meter Type

 field before you set the 

Meter Model / Size

 . The 

Billing Units

 change 

automatically when you change the 

Unit of Measure

 . The 

Unit of Measure

 value does 

not

 have to be the same as the 

Rate of 

Flow

 

Units.

 (Even in a cubic foot meter, the flow rate can be gallons per minute .)

Figure 13: Unprogrammed values

Apply Current Settings

After changing a setting, you must apply the change to program the new value to the register . 
With the IR head aligned, click Apply Current Settings to program the new values to the register . 
The new values display on the screen and the field labels are no longer bold . The register also goes into storage mode . In 

storage mode, the register displays the 

meter type, digit resolution from the register

 and 

unit of measure

 . 

Figure 14 

is an example 

of a Model 35 Disc Meter register display with a 9-digit output, measuring in gallons .

GAL

Figure 14: Meter type, digit resolution from the register and unit of measure

Updating Multiple Registers

If you want to program multiple registers with the same settings, attach the IR head bracket with the IR cable to each register, 

one at a time, and click Apply Current Settings to program each register with the same settings . 

OTEE:

N

Do not Read the subsequent register(s) before clicking Apply Current Settings .

Page 10 

May 2018

REG-PM-02658-EN-01

Содержание HR-LCD Pulse

Страница 1: ...High Resolution LCD Register HR LCD Pulse HR LCD 4 20 scaled unscaled REG PM 02658 EN 01 May 2018 Programming Manual...

Страница 2: ...High Resolution LCD Register HR LCD Pulse HR LCD 4 20 scaled unscaled Page ii May 2018 REG PM 02658 EN 01...

Страница 3: ...ultiple Registers 10 Programmer Parameters 11 Serial Field 11 Version Field 11 Meter Type Field 11 Meter Model Size Field 12 Unit of Measure Field 12 Billing Units Field 13 Visual Reading Field 13 Rat...

Страница 4: ...High Resolution LCD Register HR LCD Pulse HR LCD 4 20 scaled unscaled Page iv May 2018 REG PM 02658 EN 01...

Страница 5: ...re available for programming HR LCD registers 67660 001 Programming kit CD Kit includes IR head bracket and programmer software CD 68468 001 Programming kit USB Kit includes IR head bracket programmer...

Страница 6: ...rough the bracket opening as shown in Figure 2 NOTE N Moving the encoder lid up and down while sliding the bracket on helps to move the bracket into the correct position Figure 1 Slide bracket onto re...

Страница 7: ...on 1 Double click the LCD Programmer shortcut Figure 4 to start the software application The License Agreement displays the first time you access the software Figure 4 Software shortcut 2 Read the Lic...

Страница 8: ...s received the software determines the register type and populates the Programmer screen data fields as shown in Figure 8 For more information see Register Types on page 9 If the register is programme...

Страница 9: ...f the screen Software parameters that display vary depending on the device type Examples of completed Programmer screens for both register types are displayed here Figure 11 HR LCD Pulse register scre...

Страница 10: ...ings After changing a setting you must apply the change to program the new value to the register With the IR head aligned click Apply Current Settings to program the new values to the register The new...

Страница 11: ...serial number You cannot change the serial number Version Field The Version field Figure 15 is a read only field that displays the register version You cannot change the version number Figure 15 Seria...

Страница 12: ...of the table Disc inches Model CSM inches Model TSM inches Model 5 8 5 8 x 3 4 LP 2 High Side 1 1 2 T160 5 8 5 8 x 3 4 M25 2 Low Side 2 T200 3 4 M35 3 High Side 3 T450 1 M40 3 Low Side 4 T1000 1 M55 4...

Страница 13: ...its value If you do not want the dashed lines to display select 0 zero as the Billing Units value Figure 20 Figure 19 Billing Units value 0 zero Figure 20 Billing Units value 0 zero Visual Reading Fie...

Страница 14: ...are gallon cubic meter liters cubic feet and imperial gallon as shown in Figure 22 Figure 22 Rate of Flow Units Rate of Flow Time Field The Rate of Flow Time field displays the time unit set for the...

Страница 15: ...w Indicators The Status Indicators pop up window displays Figure 25 2 To clear the indicators click Clear Indicators in the pop up window NOTE N The Clear Indicators button does NOT clear the Programm...

Страница 16: ...In most cases this is the maximum flow rate of the meter The Damping Factor is the value used to stabilize the analog output signal Scaled Output Parameters The Scaled Output Parameters field Figure...

Страница 17: ...lses field which displays the number of unscaled output pulses per Unit of Measure from the register You cannot change the value in this field The Per Unit of Measure field which displays the unit use...

Страница 18: ...EXITING THE SOFTWARE APPLICATION To exit and close the software application click the X in the top right corner of the software screen as shown in Figure 31 Figure 31 Click the X to exit software Pag...

Страница 19: ...Appendix APPENDIX Page 19 May 2018 REG PM 02658 EN 01...

Страница 20: ...nstallation The Welcome screen displays Figure 32 Software Installer Wizard Welcome screen 2 Click Next The Select Installation Folder screen displays Figure 33 Software files location 3 Click Next to...

Страница 21: ...iefly Figure 35 Then the Installation Complete screen displays Figure 36 Figure 35 Progress bar shows installation in progress 5 At the Installation Complete screen click Close to exit the installer T...

Страница 22: ...IR cable The example Figure 37 shows COM 7 for the IR cable connected with a USB to serial adapter Prolific USB to Serial Comm Port 2 Write down the COM port number for use with the Programmer softwa...

Страница 23: ...Programming Manual INTENTIONAL BLANK PAGE Page 23 May 2018 REG PM 02658 EN 01...

Страница 24: ...ia Guadalupe Inn CP 01050 M xico DF M xico 52 55 5662 0882 Europe Eastern Europe Branch Office for Poland Latvia Lithuania Estonia Ukraine Belarus Badger Meter Europe ul Korfantego 6 44 193 Knur w Pol...

Отзывы: