Mounting Cleat
Figure 5: Transducer mounting chain hooked onto mounting cleat
OTE:
N
The chains do not need to be taut at this point. Any slack in the chains is removed when the thumbscrews
are adjusted.
1/2 in.
(12 mm)
Mounting
Cleat
Mounting
Cleat
Figure 6: Application of acoustic couplant
6. Finger tighten the position adjustment thumbscrew enough to hold the mounting rail in place, but not so tight that all of
the couplant squeezes out of the gap between the transducer faces and the pipe.
7. Route the transducer cables back to the flow meter location, avoiding high voltage cable trays and conduits.